background image

26

Please consult your manual for full information or consult your local dealer.

Service checks

Oil – Check (Level)

Oil is toxic. If you swallow any oil, do not induce 
vomiting, seek medical advice. Used engine oil 
contains harmful contaminants which can cause skin 
cancer. Do not handle used engine oil more than 
necessary. Always use barrier cream or wear gloves to 
prevent skin contact. Wash skin contaminated with oil 
thoroughly in warm soapy water. Do not use petrol, 
diesel fuel or paraffin to clean your skin.

WARNING! Never check the oil 
level or add oil with the engine 
running. Be careful of hot 
lubricating oil. Danger of scalding.

NOTE:

 Do not exceed the correct level of engine 

oil in the sump. If there is too much engine oil, the 
excess must be drained to the correct level. An 
excess of engine oil could cause the engine speed 
to increase rapidly without control.

Engine oil and oil filter change must be completed 
in accordance with the service schedules. Failure to 
change the oil and filter at the recommended 
interval could cause serious engine failure.

1. 

Stop the engine and allow it to cool.

2. 

Make the machine safe.

3. 

 Wait for the oil to drain back into the engine 
sump before you take a reading. If not, a false 
low reading may be recorded which can 
cause the engine to be overfilled.

4. 

Get access to the engine.

5. 

Remove and clean the dipstick.

6. 

Replace the dipstick.

7. 

Remove the dipstick.

8. 

 Check the oil level. The oil should be 
between the two marks on the dipstick.

9. 

If necessary, add more oil:

 

9.1.

  Remove the filler cap.

 

9.2.

   Add the recommended oil slowly 

through the filler point.

 

9.3.

  Replace the dipstick.

 

9.4.

  Remove the dipstick.

 

9.5.

   Check the oil level, if necessary  

add more oil.

 

9.6.

  Replace the dipstick.

 

9.7.

  Replace the filler cap.

Содержание G625RS

Страница 1: ...1 RS T4F Diesel Generator G625RS Quick Start Guide EN XXXX XXXX ISSUE A 09 2020...

Страница 2: ...uled out This Quick Reference Guide DOES NOT replace the Operators Manual You MUST read ALL the disclaimers and safety and other instructions in the Operators Manual before initially operating this pr...

Страница 3: ...Dimensions volumes 4 Key components 5 General checks 9 Control panel 12 Battery isolator 19 Multi voltage selection 20 Fuel connections 21 Positioning 22 Lifting 23 Emergency stops 24 Maintenance sche...

Страница 4: ...1772 Dimensions with trailer inches LxWxH 256 x 104 x 122 Weight operating with trailer lbs 24752 Aftertreatment SCR Fuel tank capacity US gallon 593 Fuel consumption 75 PRP US gallon 24 2 Fuel autono...

Страница 5: ...A Trailer B Right front door C Right centre front door D Right centre rear door E Rear right door F Rear door G Front door H Left front door J Left centre front door K Left centre rear door L Left re...

Страница 6: ...generator A Bulkhead B Radiator C Battery D Alternator E Fuel tank filler F DEF Diesel Exhaust Fluid tank filler G Voltage control rotary switch H Air filter J SCR Selective Catalytic Reduction A Exh...

Страница 7: ...ng G Charge air cooler high pressure turbo H EMS Electronic Monitoring System J Main fuel filter Fig 3 D C E F G H J B A J E G H F D C B A D C E F G H J B A J E G H F D C B A A Coolant filler B Expans...

Страница 8: ...iliary indicator lamps B Audible alarm C BUS live indicator D Audible alarm E Lockable door F Coolant heater and battery charger sockets G GFCI 120V Small power H USB Universal Serial Bus port J Volta...

Страница 9: ...f fuel or if the fuel supply has been reconnected then the fuel system must be primed prior to starting Check for fuel leaks during this process Check level of coolant in machine radiator and top up i...

Страница 10: ...o allow good airflow through the machine Check that the engine intake air filter is correctly fitted and that there are no obstructions to the incoming air Make sure that all the engine access doors a...

Страница 11: ...talled to prevent accidental rotation of the multi voltage switch whilst the generator is running otherwise damage will be caused to the alternator Checks after running Ensure that the electrical load...

Страница 12: ...uid percentage Shows the percentage of DEF B Breaker Control Closes the breaker C Date and Time Shows the controller data and time D EAT Exhaust After Treatment dashboard Opens EAT dashboard shortcut...

Страница 13: ...r G625RS 13 Item Function K AOP Opens Additional Operator Panel shortcut L Breaker Control Opens Breaker M Generator Control Starts Generator N Generator Control Stops Generator P Instrument Values Sh...

Страница 14: ...ote start function the controller must be set to semi auto mode by pressing the mode change button 4 Press the start button The generator controller will display the start up sequence 5 Engine will no...

Страница 15: ...o be kept on Stopping Procedure Perform the procedure below to stop the generator 1 Turn off all loads to the generator 2 Open the main circuit breaker The power available lamp will go off 3 Press the...

Страница 16: ...r on load Close Generator Output becomes active To place the generator off load use the Open Generator button The module automatically ramps the load off the generator and then takes it off load Close...

Страница 17: ...status of the CAN communication and to prime the fuel system Used for navigating the instrumentation event log and configuration screens Used to silence the audible alarm in the controller de activat...

Страница 18: ...eed and stabilise 9 Check that the machine operation is correct using the screen information 10 Make sure the power on LED is illuminated on earth leakage trip and there is no trip active 11 Turn on t...

Страница 19: ...a working cycle or if the machine is being left unattended and the lights are not required the battery must be isolated The control system is designed such that if the battery isolator is switched off...

Страница 20: ...ck Fig 11 IMPORTANT NOTE Operation of the rotary switch must only be carried out with the generator in stop mode and electrically isolated to prevent personal injury and damage to the equipment Change...

Страница 21: ...fully engaged in the chosen position Please consult the manual for details of maximum distances and acceptable elevation of bulk fuel tanks A B K J H E G F C D Fuel connections where fitted A External...

Страница 22: ...terminal box and through other panels should be installed using the appropriate cable glands The generating set should be located to provide suitable access for regular maintenance servicing and repa...

Страница 23: ...nd not for the weight of the fully assembled generating set Lifting NOTE Always ensure that lifting equipment is rated to lift the load Weights are shown on the generator rating plate on the side of t...

Страница 24: ...machine becomes unsafe and does not shutdown automatically Emergency stops NOTE Activation of either of the emergency stop buttons will put the generator into a fault mode As well as manually resetti...

Страница 25: ...oolant quality and level Check O O o o Oil level Check O O o o Water separator fuel filter Drain O o o Oil filter Change o o DEF filter Change o Air cleaner outer element Change o Water separator fuel...

Страница 26: ...evel An excess of engine oil could cause the engine speed to increase rapidly without control Engine oil and oil filter change must be completed in accordance with the service schedules Failure to cha...

Страница 27: ...necessary 1 Make the machine safe 2 Let the engine cool 3 Get access to the radiator filler cap and expansion bottle 4 Check the level of coolant in the radiator and in the expansion bottle If necessa...

Страница 28: ...lter indication 1 Make the machine safe 2 Get access to the air filter 3 Check the system hoses for 3 1 Condition 3 2 Damage 3 3 Security 4 Replace the system hoses if necessary 5 No cleaning or re us...

Страница 29: ...RS T4F Diesel Generator G625RS 29 Your notes...

Страница 30: ...30 Please consult your manual for full information or consult your local dealer Your notes...

Страница 31: ...RS T4F Diesel Generator G625RS 31 Your notes...

Страница 32: ...for guidance only and may vary dependant upon the exact specification of the machine They should not therefore be relied upon in relation to suitability for a particular application Guidance and advic...

Отзывы: