2.2.5 Typical Approved Installation of an Offset in JC Bordelet Smoke Pipe
2.2.6 Installation of Anti-Sway Bracket
If the central fireplace and smoke pipe installation reach a height of 3m (10’) from floor to ceiling
then an Anti-Sway bracket must be installed at about 1.83m (6’) to 2.13m (7’) to stabilize the
installation and prevent oscillations which might, in the long run, loosen fasteners and lead to leaks
and failure of the smoke pipe and Load Bearing Support.
Page 11
CAUTION:
If the central
fireplace and smoke pipe
installation reach a height
of 3m (10’) from floor to
ceiling then an Anti-Sway
bracket must be installed
at about 1,83m (6’) to
2,13m (7’) to stabilize the
installation and prevent
oscillations which might,
in the long run, loosen
fasteners and lead to leaks
and failure of the smoke
pipe and Load Bearing
Support.