33
FNS-0012-060-EN June 2019 Rev A
Operator Maintenance (continued)
2. Check
orifice
tube
for
damage.
Refer to Figure 9.
Replace tube when:
a. Chunks are missing from top end.
b. Score marks 1/32" or deeper appear along the length of the tube.
Figure 9. Severely Damaged Orifice Tube
3. Check
for
loose
or
missing
nuts
and
bolts.
a. Tighten or replace nuts and bolts as necessary.
b.
DO
NOT
exceed torque ranges specified.
c.
ALWAYS
use JBT Corporation recommended spare parts.
Periodic Inspection
Perform the following steps every week.
1. Test all access cover interlock switches.
Juicer should stop automatically when any access cover is opened. Individually open and
close the front door and hopper access door.
If juicer continues to run when front door or hopper access is opened, the interlock switch is
defective. Stop the juicer and call service provider immediately.
See Troubleshooting Section.
2. Inspect casters for damage or wear.
Caster must roll freely and front and rear brakes must lock.
Содержание Fresh'n Squeeze 2nd Generation Multi-Fruit...
Страница 1: ...June 2019 2nd Generation Multi Fruit Juicer Operator Manual...
Страница 8: ...8 FNS 0012 060 EN June 2019 Rev A Figure 2 Juicing Components Assembly...
Страница 22: ...22 FNS 0012 060 EN June 2019 Rev A Figure 6 Removing Replacing Juicing Components...
Страница 28: ...28 FNS 0012 060 EN June 2019 Rev A Figure 1 Removing Replacing Self Service Juicing Components...
Страница 30: ...30 FNS 0012 060 EN June 2019 Rev A Figure 7 Proper Orifice Tube Installation...
Страница 32: ...32 FNS 0012 060 EN June 2019 Rev A Figure 8 Sharpening Cutter...
Страница 40: ...40 FNS 0012 060 EN June 2019 Rev A...