manualshive.com logo in svg
background image

ENGLISH  

OPERATION 

MANUAL 

 

 
JB SYSTEMS® 

3/27 

TYPHOON 

LAMP (RE)PLACEMENT 

In case of replacement of the lamp or maintenance, do not open the fixture within 10 
minutes until the unit cools down after switching off. Always unplug the unit before 
servicing! Always use the same type of spare parts (bulbs, fuses, etc.) When replacing 
parts, please only genuine spare parts. 

  Unplug the mains cable.  

  Wait for about 10 minutes until the unit has been cooled down. 

  Unscrew the screws that close the lamp compartment of the fixture and open it.  

  On the inside you will see the lamp sockets.  

  Unplug the old lamps. (turn the rotor with your hands to access on the opposite side) 

  Hold the lamp socket while pressing the new lamps gently in the socket.

 

 

Attention! 

Check the label on the backside of the device or see the technical specifications in this manual 

to know which lamp should be used. Never install lamps with a higher wattage! Lamps with higher wattage 
generate temperatures the device was not designed for. If the device uses a lamp transformer, it will burn 
due to current overload. 

  Don’t touch the bulbs with bare hands! This drastically shortens the lifespan of the 

lamps. If you touched the lamp, clean it with a cloth and a little denatured alcohol. 
Wipe the lamp off before installing. 

  Close the lamp compartment.  

 Done! 

 
 

OVERHEAD RIGGING 

 

Important:

 

The installation must be carried out by qualified service personal only. Improper 

installation can result in serious injuries and/or damage to property.  Overhead rigging requires 
extensive experience! Working load limits should be respected, certified installation materials 
should be used, the installed device should be inspected regularly for safety.

 

  Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging 

and servicing. 

  Locate the fixture in a well ventilated spot, far away from any flammable materials and/or liquids. The 

fixture must be fixed 

at least 50cm

 from surrounding walls. 

  The device should be installed out of reach of people and outside areas where persons may walk by or be 

seated. 

  Before rigging make sure that the installation area can hold a minimum point load of 10times the device’s 

weight. 

  Always use a certified safety cable that can hold 12times the weight of the device when installing the unit. 

This secondary safety attachment should be installed in a way that no part of the installation can drop 
more than 20cm if the main attachment fails. 

  The device should be well fixed; a free-swinging mounting is dangerous and may not be considered! 

  Don’t cover any ventilation openings as this may result in overheating.  

  The operator has to make sure that the safety-relating and machine-technical installations are approved by 

an expert before using them for the first time. The installations should be inspected every year by a skilled 
person to be sure that safety is still optimal. 

 
 

OPERATING INSTRUCTIONS 

  Once connected to the mains the device starts running. 

  If necessary, adapt the music sensitivity.  

  Regular breaks during operation are essential to maximize the life of this device as it is not designed for 

continual use. 

  Do not switch the unit on and off in short time intervals as this reduces the lamp life. 

  The units’ surface temperature may reach up to 85°C. Don’t touch the housing with bare-hands during its 

operation. 

  Always unplug the unit when it is not used for a longer time or before replacing the bulb or start servicing. 

  In the event of serious operating problems, stop using the fixture and contact your dealer immediately. 

ENGLISH  

OPERATION 

MANUAL 

 

 
JB SYSTEMS® 

4/27 

TYPHOON 

 

Important: 

Never look directly into the light source! Don’t use the effect in the presence of persons 

suffering from epilepsy. 

 
 

MAINTENANCE 

  Make sure the area below the installation place is free from unwanted persons during servicing. 

  Switch off the unit, unplug the mains cable and wait until the unit has been cooled down. 

During inspection the following points should be checked: 

  All screws used for installing the device and any of its parts should be tightly fastened and may not be 

corroded. 

  Housings, fixations and installations spots (ceiling, truss, suspensions) should be totally free from any 

deformation. 

  When an optical lens is visibly damaged due to cracks or deep scratches, it must be replaced. 

  The mains cables must be in impeccable condition and should be replaced immediately when even a 

small problem is detected. 

  In order to protect the device from overheat the cooling fans (if any) and ventilation openings should be 

cleaned monthly. 

  The interior of the device should be cleaned annually using a vacuum cleaner or air-jet. 

 The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to 

optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp, 
smoky or particularly dirty surroundings can cause greater accumulation of dirt on the unit’s optics. 

  Clean with a soft cloth using normal glass cleaning products. 

  Always dry the parts carefully. 

  Clean the external optics at least once every 30 days.  

  Clean the internal optics at least every 90 days. 

Attention: We strongly recommend internal cleaning to be carried out by qualified personnel! 
 
 

SPECIFICATIONS 

Mains Input: 

AC 230V, 50Hz  

Fuse: 

250V 5A slow blow (20mm glass) 

Sound Control: 

Internal microphone 

Lamp:

 

2x BVM 300W / 120V (2x Osram 64514) 

Size:

 

35 x 35 x 18cm  

Weight:

 5,5kg 

 

Every information is subject to change without prior notice

Содержание TYPHOON

Страница 1: ...cva Reproduction or publication of the content in any manner without express permission of the publisher is prohibited Operation Manual Mode d emploi Gebruiksaanwijzing Bedienungsanleitung Manual de i...

Страница 2: ...t toestel en de gebruikte batterijen op een milieuvriendelijke manier conform de in uw land geldende voorschriften DU ENTSORGUNG DES GER TS Entsorgen Sie das Ger t und die Batterien auf umweltfreundli...

Страница 3: ...lated spot away from any flammable materials and or liquids The fixture must be fixed at least 50cm from surrounding walls Don t cover any ventilation openings as this may result in overheating Preven...

Страница 4: ...s to make sure that the safety relating and machine technical installations are approved by an expert before using them for the first time The installations should be inspected every year by a skilled...

Страница 5: ...z l appareil dans un endroit bien ventil loign de tout mat riau ou liquide inflammable L appareil doit tre fix 50cm minimum des murs FRAN AIS MODE D EMPLOI JB SYSTEMS 6 27 TYPHOON Ne pas couvrir les o...

Страница 6: ...s ou des zones o le public est install Avant l installation assurez vous que la zone d installation supporte un point localis minimum de 10 fois le poids de l appareil Utilisez syst matiquement un c b...

Страница 7: ...shows Driezijdig geslepen lenzen cre ren een veelvoud van gekleurde stralen Deze stralen dansen door elkaar op het ritme van de muziek ALVORENS HET APPARAAT IN GEBRUIK TE NEMEN Controleer voor het eer...

Страница 8: ...t dezelfde elektrische kenmerken Ingeval van ernstige problemen met het bedienen van het toestel stopt U onmiddellijk het gebruik ervan Contacteer uw dealer voor een eventuele reparatie De behuizing e...

Страница 9: ...bedienen van het apparaat de behuizing niet met blote handen aan Trekt U altijd de stekker uit het stopcontact als het apparaat langere tijd geen dienst doet of alvorens een lamp te vervangen of alvor...

Страница 10: ...lgegenst nde oder Fl ssigkeiten ins Innere des Ger ts gelangen lassen Kurzschlu oder Fehlfunktion k nnen die Folge sein Falls es doch einmal vorkommen sollte bitte sofort Netzstecker ziehen und vom St...

Страница 11: ...rstellen dass die sicherheitsrelevanten und technischen Installationen vor Erstbetrieb fachm nnisch vorgenommen worden sind Installationen sollten j hrlich durch qualifiziertes Fachpersonal inspiziert...

Страница 12: ...licos o derrame l quidos dentro de la unidad Podr a resultar descarga el ctrica o mal funcionamiento Si un objeto extra o entrara en la unidad desconecte inmediatamente la fuente de alimentaci n Coloq...

Страница 13: ...i n deben ser usados el aparato instalado deber a ser inspeccionado regularmente por seguridad Aseg rese de que el rea por debajo del sitio de instalaci n est libre de personas ajenas durante el monta...

Страница 14: ...CTER STICAS Esta unidade est protegida contra interfer ncias r dio Este produto cumpre as exig ncias impostas pelas presentes directivas nacionais e europeias A conformidade deste produto foi comprova...

Страница 15: ...da COLOCAR SUBSTITUIR A L MPADA Em caso de substitui o da l mpada ou manuten o aguarde 10 minutos ap s desligar a unidade Desligue sempre a unidade da corrente antes de efectuar a manuten o Utilize se...

Страница 16: ...te a inspec o dever verificar os seguintes pontos Todos os parafusos utilizados nas pe as da unidade e na instala o dever o estar apertados firmemente e n o poder o estar corro dos A cobertura da unid...

Отзывы: