background image

3

Description

The MPC Series from JBL is a line of professional power amplifiers specifically designed for

contracting applications. There are six models, each with two independent channels. Each

model in the MPC Series line is available in a “T” version for driving either 200V, 140V, 100V,

70V, 50V, or 25V “constant voltage” lines and in a “non-T” versions for driving loudspeaker

systems with impedances as low as 2 ohms. (See section on bridging for information about

200V, 140V, and 50V drive capabilities).

Power Capabilities—

The table below lists the power ratings under various load conditions:

l

e

d

o

M

4

1

2

2

s

t

l

o

V

0

0

1

s

t

l

o

V

0

7

s

t

l

o

V

5

2

0

0

2

C

P

M

2

×

W

5

2

2

2

×

W

0

5

3

T

0

0

2

C

P

M

2

×

W

5

2

2

2

×

W

0

5

3

2

×

W

5

7

1

3

2

×

W

5

7

1

3

2

×

W

0

5

1

3

0

0

3

C

P

M

2

×

W

0

0

3

2

×

W

0

5

4

T

0

0

3

C

P

M

2

×

W

0

0

3

2

×

W

0

5

4

2

×

W

0

5

2

4

2

×

W

0

5

2

4

2

×

W

0

0

2

4

0

0

6

C

P

M

2

×

W

0

0

6

2

×

W

0

0

9

T

0

0

6

C

P

M

2

×

W

0

0

6

2

×

W

0

0

9

2

×

W

0

0

5

4

2

×

W

0

0

5

4

2

×

W

0

0

4

4

1

FTC watts per channel, 20 Hz–20 kHz, 0.1% THD

2

EIA watts per channel, 1 kHz, 1% THD

3

Watts per channel, band limited for 50 Hz–15 kHz response, 0.25% THD

4

Watts per channel, band limited for 45 Hz–15 kHz response, 0.25% THD

Channel Separation—

Each channel has its own power transformer secondary to provide

maximum audio separation (minimum sound leakage) between the two channels, minimizing

interaction that can otherwise occur on amplifiers with a common power supply.

High Efficiency—

The MPC200, 200T, 300 & 300T utilize complementary Class AB linear

output circuitry. For improved efficiency, the MPC600 and 600T utilize Class H step-linear

complementary output circuitry using multi-rail power supplies.

High Cooling Capacity—

Every MPC amplifier features a large diameter two-speed fan and

massive extruded aluminum heat sinks. The output devices couple 

directly

 to the heat sink.

This provides better cooling of the output devices while eliminating problematic insulating

wafers that are an integral part of  most other amplifier designs. Forced air cooling in a back-

to-front direction provides for more effective cooling, preventing problems that otherwise

occur from a continual heat build-up inside the equipment rack, which occurs in amplifiers

with front-to-back or side-to-side flow schemes. These design factors allow the MPC amplifi-

ers to work in high duty-cycle instances when many other professional amplifiers cannot.

Weight Balance—

The power transformers, as well as the output transformers on the T

models, are mounted in the front of the amplifier chassis, as close to the front mounting rails

as possible. This keeps the unit’s center of gravity forward to minimize the twisting force on

the front mounting ears.

Rail Support—

The amplifier should be supported at all four corners, especially if it is in a

portable rack. The flow-through cooling scheme allows you to rack-mount the amplifiers on

top of the other, with no clearance necessary in between. This mounting technique also helps

support the weight of the upper amplifiers. In permanent fixed installations, the rear of the

amplifiers can receive physical support by installing the amplifiers at the bottom of  the

equipment rack. Make sure that the direct weight of  the back of the amplifier is supported

from the bottom of the rack.

Dimensions—

a) Height—The MPC200 and 200T are 2 rack spaces high. The MPC300, 300T, 600 and

600T are 3 rack spaces high.

All manuals and user guides at all-guides.com

Содержание MPC Series

Страница 1: ...21 MPC Series Power Amplifiers Owner s Manual TD 000074 00 TD 000074 00 Rev C All manuals and user guides at all guides com a l l g u i d e s c o m...

Страница 2: ...11 MPC300 300T 600 600T Bridged Mono Configuration 11 Bridged Mono Speaker Connection 11 Low Impedance Bridged Mono 12 High Impedance Bridged Mono 12 Parallel Mono Configuration 12 Controls 13 Displa...

Страница 3: ...i Personen zu verteilen Cautions Sicherheitsvorschriften CAUTION TO AVOID ELECTRIC SHOCK DO NOT INSERT FINGERS OR OBJECTS INTO ANY OPENINGS IN THE CHASSIS VORSICHT UM ELEKTRISCHEN SCHLAG ZU VERMEIDEN...

Страница 4: ...utput circuitry using multi rail power supplies High Cooling Capacity Every MPC amplifier features a large diameter two speed fan and massive extruded aluminum heat sinks The output devices couple dir...

Страница 5: ...8 Detachable Input Header Block 9 Cooling Fan 10 Shrouded Output Connector Direct Outputs 11 Shrouded Output Connector Audio Transformer Outputs 12 Mounting Holes for Optional Handles 13 Rear Support...

Страница 6: ...resets to normal when conditions assure safe operation Inputs MPC amplifiers feature balanced inputs connected via a Euro style 7 terminal detachable header Channel 2 Channel 2 Ground Ground Ground Ch...

Страница 7: ...L OUTPUT AUDIO TRANSFORMER 70V 25V 8 4 2 100V 0 70 100 CH1 CH1 BRIDGE MONO LOW IMPEDANCE DIR OUTPUT ISOL OUTPUT AUDIO TRANSFORMER 70V 25V 100V 0 70 100 CH1 CH1 BRIDGE MONO LOW IMPEDANCE DIR OUTPUT ISO...

Страница 8: ...ut while the 100V or 70V output drives backstage monitors or restaurant loudspeakers Application Example 3 Extending low frequency performance Adding a low impedance subwoofer 4 or 8 to a distributed...

Страница 9: ...low impedance capabilities diminish 1 Computing maximum allowable distributed line loading with a known low impedance load The formula is MaxATP RatedLZP 2 RatedLZP Impedance 2 MaxATP is the sum of th...

Страница 10: ...If it is lit about half the time the amplifier channel will probably go into thermal protection within a few minutes 2 Computing the minimum low impedance load with a known distributed line load The f...

Страница 11: ...sorties aussi lev e que 160 volts rms sont disponible aux bornes du amplificateur MPC en mode bridg mono 200 volts aux sorties isol s MPC200T MPC300T et MPC600T op ration 140V et 200V On doit utiliser...

Страница 12: ...level Both channels SIGNAL and CLIP indicators should flash identically when the amplifier is operating Bridged Mono Speaker Connection Low impedance A speaker load of 4 ohms or higher can be connect...

Страница 13: ...SE High Impedance Bridged Mono Distributed System Bridged Mono Applications Placing the T models in bridged mono mode permits higher drive voltages 140V and 200V for reducing the effect of cable resis...

Страница 14: ...el They have 11 detents and are adjustable from 0 dB full gain to full attenuation Displays The LED displays on models MPC200 and 200T are different from those on models MPC300 300T 600 and 600T Model...

Страница 15: ...on each channel lights for about 2 to 3 seconds during which the output relays mute the speakers After the turn on muting interval the PROTECT LEDs turn off the green POWER LEDs light and the output...

Страница 16: ...the load against damage The amplifier s high pass filter described below will itself block DC coming into the amplifier inputs The amplifier s Output Averag ing protection circuitry limits current to...

Страница 17: ...ive or under impedance loads Load Protection Turn on turn off muting DC fault load grounding relay MPC300 300T 600 600T with internal fault fuses Power Requirements 100V 120V 220 230V AC 50 60 Hz Not...

Страница 18: ...ability to operate at 1 3 power in order to meet worst case demands The electrical current consumption at 120 VAC for each audio power level and load impedance is shown in the table below Multiply th...

Страница 19: ...P M T 0 0 2 C P M 8 8 5 4 6 3 6 1 5 1 6 5 5 1 0 1 5 8 2 1 5 8 2 2 4 4 5 6 2 1 8 1 3 0 6 0 1 7 6 2 0 3 8 0 1 2 5 8 2 2 2 2 0 4 3 2 0 9 5 0 0 7 1 9 2 4 5 9 2 1 6 2 3 5 8 2 2 V 0 0 1 V 0 7 V 5 2 5 6 3 1...

Страница 20: ...ounting screws on the input panel except MPC200 200T If they are loose the panel itself might not be well grounded to the chassis In some cases such as when the audio signal cables are routed near lig...

Страница 21: ...ation by contacting the factory or repair facility directly Please ship amplifiers in the original packing materials or equivalent to prevent further damage during shipment and insure the shipment ade...

Страница 22: ...22 JBL Professional 8500 Balboa Boulevard P O Box 2200 Northridge California 91329 U S A A Harman International Company MPC MANUAL 6 98 All manuals and user guides at all guides com...

Отзывы: