PREPARING FOR INSTALLATION

Before  starting  to  install  the  Intellivox  loudspeaker,  a

number of points should be considered.

• It is assumed that the installation site has been the

subject of an extensive DDA investigation or optimisation

prior  to  the  actual  install.  (DDA  =  Digital  Directivity

Analysis,  the  proprietary  simulation  and  optimisation

software  for  these  products*). This  procedure  will  have

identified the optimum physical location for the Intellivox,

to  accurately  achieve  the  desired  acoustic  coverage.  In

particular, the “acoustic centre” position will have been

specified, in terms of height above the finished floor. The

installer 

should 

confirm 

that 

he/she 

has 

this information.

• Unless  specified  otherwise  by  the  sound  system

designer,  the  Intellivox  column  should  be  installed  at  a

position exactly perpendicular to the listening plane (i.e.

vertical  if  the  floor  is  horizontal).  Unlike  conventional

loudspeaker systems, minor mechanical misalignment may

lead to degraded coverage and intelligibility. Ensure (by use

of a levelling device such as a spirit level) that the surface

to  which  the  Intellivox  is  to  be  attached  is  absolutely

vertical and that all mounting positions (2 or 3 depending

on model) are in the same plane.

• The  Intellivox  is  configured  to  operate  from  either   

230 V or 115 V AC mains.  A suitable AC mains outlet should

be provided adjacent to the loudspeaker’s intended mounting

position, taking the position of the electronics module into

account. The outlet must be on a circuit able to handle the

full-load power consumption as well as supply the maximum

in-rush current drawn by the electronics module; these figures

vary with model, and can be found in the datasheet supplied

with the unit. The third terminal of the mains outlet must be

connected to a proper safety ground. Local safety regulations

may  require  a  separate  mains  distribution  network  or  an

uninterruptible mains power supply (UPS).

SIGNAL AND CONTROL CABLES

• In addition to the mains supply, some or all of the following

cables (shown in fig 4) will need to be run to the loudspeaker

position.  The  necessity  for  each  of  these  will  have  been

determined by the system designer; the installer should ensure

that he/she has these details to hand. Depending on the specific

access issues, it may be better to ensure that these cables are

in place and correctly terminated “ready-to-plug-in” before the

Intellivox is mounted in position. All wiring details can be found

on pages 9-15.

• Audio  inputs:  the  Intellivox  accepts  line  level  audio 

(0 dBV). Two separate transformer-balanced audio inputs

are provided; however, units are shipped with only input 1

active.  Input  2  can  be  made  active  via  WinControl.

Alternative  input  sections  are  available  separately:

accepting either one line level input and one 70 V/100 V

input or two 70 V/100 V inputs. This option needs to be

specified at the time of ordering.

• Network  connection:  all  Intellivox  products  are

configured, and may also be monitored, from a PC running

WinControl software. With all installations it will be 

3. INSTALLATION GUIDE

*Authorised electro-acoustic consultants or 'build & design' sound contractors can apply for a DDA License free of charge.

This license can be obtained through our website at http://www.jblpro.com/
For further information please refer to the Help files and manual with the DDA software.

Audio

RS-485

AC Mains

supply

External

Ambient noise 

+ Temperature

sensor

Failure Relay / 

Fan Control

REQUIRED

CONNECTIONS

OPTIONAL

CONNECTIONS

fig.4 - Intellivox Connections

Содержание Intellivox-DC115

Страница 1: ...0 500 models Part Nos 585000 585001 585020 585021 585060 585061 585120 585121 585160 585161 585300 585301 587000 587001 587020 587021 587040 587041 587060 587061 587080 587081 587120 587121 587140 587...

Страница 2: ...518077 Zaltbommel January 2012 USER S NOTICE AND DISCLAIMER No part of this manual including the software described in it may be reproduced transmitted transcribed stored in a database system or trans...

Страница 3: ...nnectors 10 Audio inputs 11 Network connection 12 Fault monitoring fan control connector 13 14 External Ambient SPL Temperature Sensor 15 Mechanical Installation 16 Acoustic centre 16 Mounting Options...

Страница 4: ...nufacturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip over 13 Unplug this apparatus during lightning storms or when...

Страница 5: ...the WinControl Help les Please note that a full range of optional mounting brackets and connection coverboxes are available Please refer to our website for further details APPLICABLE MODELS AND VARIAN...

Страница 6: ...oustical mounting height WHAT S IN THE PACKAGING In addition to the loudspeaker itself each unit is shipped with the following items Installation manual this document Datasheet speci c to the model Bo...

Страница 7: ...ctronics module these gures vary with model and can be found in the datasheet supplied with the unit The third terminal of the mains outlet must be connected to a proper safety ground Local safety reg...

Страница 8: ...s may be activated automatically via the Intellivox s temperature controlled fan output 2 core cable will be required The fan should be mounted in a position which ensures suf cient air ow around the...

Страница 9: ...ory may be used if one of a suitable length is available Otherwise use the mating IEC cable socket supplied and wire to the intended mains outlet Note that this connector is only suitable for use with...

Страница 10: ...oximately 8 9 mm 0 35 of the insulation of each core 2 Refer to the table below select the appropriate PVC insert for the wire size If the wire is too big for the largest size insert the inserts can b...

Страница 11: ...xtraneous noise Note that pins 3 and 6 of the audio connector are analogue audio grounds they should be used only for connecting the screen of the audio cables and for no other purpose Due to the comp...

Страница 12: ...connecting multiple devices to the same network subnet ensure that their network addresses do not overlap Each device should be set to a unique network address determined via WinControl In some instal...

Страница 13: ...CB jumper refer to the Appendix for details In volt free operation COM is connected to NC a failure condition causes COM to be connected to NO When con gured for impedance sensing use the impedance be...

Страница 14: ...he FAN signal is diode clamped both to the internal positive supply rail as well as to the internal GND The fan should be a 24 V DC type consuming less than 3 W Applicable fan types are EBM Papst 8314...

Страница 15: ...vel and in some circumstances it may be preferable to monitor the ambient noise at a position remote from the Intellivox itself Connecting the external ambient noise sensor automatically disconnects t...

Страница 16: ...e operational height de ned in the design process The vertical position of the acoustic centre relative to the bottom of the unit varies from one Intellivox model to another though it will always be o...

Страница 17: ...wo or three depending on the model swivel brackets are needed The horizontal angle of the swivel brackets can be secured by the hexagonal nut The swivel brackets are mounted to the rear of the enclosu...

Страница 18: ...x enclosure with the M5 x 12 pan head screws and shakeproof washers supplied The 10 mm dia holes allow screwdriver access to the screw heads 7 Lift the Intellivox and slide the brackets over the heads...

Страница 19: ...inControl is necessary but basic familiarity withWindows le handling is required A full description of WinControl is beyond the scope of this manual and further information is available in the applica...

Страница 20: ...is being accessed additional similar rectangles will be displayed If the display does not look like that shown click on Command Netscan to force the PC to re scan the network This will be the case if...

Страница 21: ...Note that Intellivox settings les always have an ini le extension Select the correct settings le and click Open Then in the Load control parameters settings dialogue box ensure that the proper parame...

Страница 22: ...ellivox wall bracket 35 mm 802235 2pcs 802236 3pcs Intellivox wall bracket 60 mm 802260 2pcs 802261 3pcs Intellivox hinge bracket 90 802000 Intellivox swivel bracket 90 806608 Intellivox swivel bracke...

Страница 23: ...0 DSX280 DSX380 DSX280HD amp at top only 20012 Weather proo ng kit for Models DC430 DS430 DSX430 amp at top only 20014 Weather proo ng kit for Models DC500 DS500 DSX500 amp at top only 20016 DESCRIPTI...

Страница 24: ...marked AGND are tted to the ambient SPL mic and temperature sensor connector and serve as a signal reference only AGND should not be connected to any other ground pin GND or DGND on the chassis The RS...

Страница 25: ...onics module Configuring PCB960 The impedance between pin 1 and 2 of the audio input connector has two states High impedance approximately 100 kOhm DC Low impedance approximately 2 2 kOhm DC The state...

Страница 26: ...jumper is placed on both contact pins of JMP2 see g 17 Always High impedance regardless of the device status The jumper should be removed Notes The fault conditions that result in impedance switching...

Страница 27: ...factory default con guration the jumper is placed on the contact pins of JMP1 that are closest to R29 furthest away from the edge of the board see g 17 Impedance sensing mode When con gured for impeda...

Страница 28: ...JBL Professional 8500 Balboa Boulevard Northridge CA 91329 U S A Copyright 2014 JBL Professional www jblpro com...

Отзывы: