background image

21

201401/IvxIM_v2.2

JBL Intellivox Installation Manual

• The File Name field (at the top of the 

Load control

parameters  settings

dialogue  box)  indicates  the

last-used settings file name. If this is the first time

that the installation of WinControl has been used, a

default settings file is selected. The default location

for  this  file  is  in  [My  Documents  folder]\

Duran

Audio BV\WinControl\Settings

, though as

this is alterable, it is possible that a different location

may be displayed, depending on how the particular PC

being used has been set up.  To navigate to the location

containing the settings file to be uploaded, click on the

Browse button

(the folder symbol to the right of

the File Name field), which will open a further 

Open

dialogue box

. Navigation may be continued in the

normal Windows manner. Note that Intellivox settings

files always have an 

*.ini

file extension.

• Select the correct settings file and click 

Open

. Then in

the 

Load control parameters settings

dialogue box,

ensure that the proper parameter groups are selected

and specify the preset(s) to be uploaded, click 

OK

* to

continue. An 

Info

dialogue box will then open showing

additional information, in this box click 

OK

to start the

upload process. This will transfer the pre-determined

Intellivox parameters to the loudspeaker. The 

Control

parameters

dialogue box can now be closed and the

upload is complete.

• If there are further loudspeakers on the network to have

their settings files uploaded at this time, the procedure

can be repeated by selecting the next Intellivox. It is

possible  to  load  the  same  settings  file  into  several

Intellivoxes  simultaneously,  should  the  installation

require  this.  See 

Addresses  and Groups

in  the

WinControl Help file for more information.

* See WinControl Help files for information regarding further Load options.

Содержание Intellivox-DC115

Страница 1: ...0 500 models Part Nos 585000 585001 585020 585021 585060 585061 585120 585121 585160 585161 585300 585301 587000 587001 587020 587021 587040 587041 587060 587061 587080 587081 587120 587121 587140 587...

Страница 2: ...518077 Zaltbommel January 2012 USER S NOTICE AND DISCLAIMER No part of this manual including the software described in it may be reproduced transmitted transcribed stored in a database system or trans...

Страница 3: ...nnectors 10 Audio inputs 11 Network connection 12 Fault monitoring fan control connector 13 14 External Ambient SPL Temperature Sensor 15 Mechanical Installation 16 Acoustic centre 16 Mounting Options...

Страница 4: ...nufacturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip over 13 Unplug this apparatus during lightning storms or when...

Страница 5: ...the WinControl Help les Please note that a full range of optional mounting brackets and connection coverboxes are available Please refer to our website for further details APPLICABLE MODELS AND VARIAN...

Страница 6: ...oustical mounting height WHAT S IN THE PACKAGING In addition to the loudspeaker itself each unit is shipped with the following items Installation manual this document Datasheet speci c to the model Bo...

Страница 7: ...ctronics module these gures vary with model and can be found in the datasheet supplied with the unit The third terminal of the mains outlet must be connected to a proper safety ground Local safety reg...

Страница 8: ...s may be activated automatically via the Intellivox s temperature controlled fan output 2 core cable will be required The fan should be mounted in a position which ensures suf cient air ow around the...

Страница 9: ...ory may be used if one of a suitable length is available Otherwise use the mating IEC cable socket supplied and wire to the intended mains outlet Note that this connector is only suitable for use with...

Страница 10: ...oximately 8 9 mm 0 35 of the insulation of each core 2 Refer to the table below select the appropriate PVC insert for the wire size If the wire is too big for the largest size insert the inserts can b...

Страница 11: ...xtraneous noise Note that pins 3 and 6 of the audio connector are analogue audio grounds they should be used only for connecting the screen of the audio cables and for no other purpose Due to the comp...

Страница 12: ...connecting multiple devices to the same network subnet ensure that their network addresses do not overlap Each device should be set to a unique network address determined via WinControl In some instal...

Страница 13: ...CB jumper refer to the Appendix for details In volt free operation COM is connected to NC a failure condition causes COM to be connected to NO When con gured for impedance sensing use the impedance be...

Страница 14: ...he FAN signal is diode clamped both to the internal positive supply rail as well as to the internal GND The fan should be a 24 V DC type consuming less than 3 W Applicable fan types are EBM Papst 8314...

Страница 15: ...vel and in some circumstances it may be preferable to monitor the ambient noise at a position remote from the Intellivox itself Connecting the external ambient noise sensor automatically disconnects t...

Страница 16: ...e operational height de ned in the design process The vertical position of the acoustic centre relative to the bottom of the unit varies from one Intellivox model to another though it will always be o...

Страница 17: ...wo or three depending on the model swivel brackets are needed The horizontal angle of the swivel brackets can be secured by the hexagonal nut The swivel brackets are mounted to the rear of the enclosu...

Страница 18: ...x enclosure with the M5 x 12 pan head screws and shakeproof washers supplied The 10 mm dia holes allow screwdriver access to the screw heads 7 Lift the Intellivox and slide the brackets over the heads...

Страница 19: ...inControl is necessary but basic familiarity withWindows le handling is required A full description of WinControl is beyond the scope of this manual and further information is available in the applica...

Страница 20: ...is being accessed additional similar rectangles will be displayed If the display does not look like that shown click on Command Netscan to force the PC to re scan the network This will be the case if...

Страница 21: ...Note that Intellivox settings les always have an ini le extension Select the correct settings le and click Open Then in the Load control parameters settings dialogue box ensure that the proper parame...

Страница 22: ...ellivox wall bracket 35 mm 802235 2pcs 802236 3pcs Intellivox wall bracket 60 mm 802260 2pcs 802261 3pcs Intellivox hinge bracket 90 802000 Intellivox swivel bracket 90 806608 Intellivox swivel bracke...

Страница 23: ...0 DSX280 DSX380 DSX280HD amp at top only 20012 Weather proo ng kit for Models DC430 DS430 DSX430 amp at top only 20014 Weather proo ng kit for Models DC500 DS500 DSX500 amp at top only 20016 DESCRIPTI...

Страница 24: ...marked AGND are tted to the ambient SPL mic and temperature sensor connector and serve as a signal reference only AGND should not be connected to any other ground pin GND or DGND on the chassis The RS...

Страница 25: ...onics module Configuring PCB960 The impedance between pin 1 and 2 of the audio input connector has two states High impedance approximately 100 kOhm DC Low impedance approximately 2 2 kOhm DC The state...

Страница 26: ...jumper is placed on both contact pins of JMP2 see g 17 Always High impedance regardless of the device status The jumper should be removed Notes The fault conditions that result in impedance switching...

Страница 27: ...factory default con guration the jumper is placed on the contact pins of JMP1 that are closest to R29 furthest away from the edge of the board see g 17 Impedance sensing mode When con gured for impeda...

Страница 28: ...JBL Professional 8500 Balboa Boulevard Northridge CA 91329 U S A Copyright 2014 JBL Professional www jblpro com...

Отзывы: