Specifications

Complete Rework station with Electric Pump
RMVE-1D 

/

 RMVE-2D 

RMVE-9D 

  - Total weight: 14 kg (30.95 lb)

  JTSE-1A 

100V - 120V 50/60Hz. Input fuse: 8A. Rated current: 7A

 JTSE-2A 

230V 50/60Hz. Input fuse: 4A. Rated current: 3A

  - Net Weight:  

 

 4.9 kg (10.86 lb)

  - Dimensions (control unit):  

148 x 184 x 140 mm (5.83 x 7.24 x 5.51 in) 

  - Nominal power:    

700W

  - Temperature selection:  

Room temp. / 150 - 450 °C (300 - 840 °F)

 

Cool mode: 

 

T off. Used to blow air to room temperature

  - Ambient operating temp.:  

10 - 40 ºC (50 - 104 ºF)

  - Air flow regulation:  

5 - 50 SLPM

  - Vacuum:  

 

30% / 228 mmHg / 9 inHg

  - Connectors: 

 

USB station-PC

   

 

 

Robot RS232

   

 

 

P-005 Pedal

  

DDE-1B

 120V 50/60Hz. Input fuse: 4A. Output: 23,5V.

  DDE-2B

 230V 50/60Hz. Input fuse: 2A. Output: 23,5V.

  DDE-9B

 100V 50/60Hz. Input fuse: 5A. Output: 23,5V.

 

- Net Weight:  

 3.8 

kg (8.41 lb)

  - Dimensions:  

 

148 x 120 x 232 mm (5.83 x 4.72 x 9.13 in)

  - Output Peak Power:  

150W per tool

  - Temperature Range:  

90 - 450 °C (190 - 840 °F) ±5%

 

- Idle Temp. Stability (still air):  

±1.5 ºC (±3 ºF)

  - Tip to ground resistance:  

<2 ohms

  - Tip to ground voltage:  

<2mV RMS

  - Ambient operating temp.:  

10 - 40 ºC (50 - 104 ºF)

  - Connections 

 

USB-A / USB-B / Peripherals connectors

  

 

 

RJ12 connector for Robot

 

MVE-A

 - 

Net Weight:   

700 gr (1.54 lb) 

  - Dimensions:   

145 x 55 x 225 mm (5.71 x 2.17 x 8.86 in)

 - 

Air Pressure supply range: 

4 - 6 Bar

  - Vacuum at 6 Bar:   

90% / 680 mmHg / 26.8 inHg

  - Flow rate:   

15 SLPM

  - Ambient operating temp.:  

10 - 40 ºC (50 - 104 ºF)

  - P-005 Pedal connection

Complies with CE standards.
ESD protected.

12

Содержание RMVE-D

Страница 1: ...Premium Complete Rework Station with Pneumatic Pump Ref RMVE D INSTRUCTION MANUAL www jbctools com...

Страница 2: ...Control Unit 1 u Ref DDE 1B 120V DDE 2B 230V DDE 9B 100V Desoldering Iron 1 unit Ref DR560 A C560003 already inserted Stand 1 unit Ref DR SE General Purpose Handle 1 unit Ref T245 A Heater hose set 1...

Страница 3: ...0 x1 Extractors Ref E2184 E2064 E2052 Protectors Ref P2220 P2230 P2235 P4000 P4010 Tripod Ref T2050 39mm T2250 85mm Nozzles Ref JN2015 x1 JN2012 x1 JN2020 x1 Sponge 1 unit Ref S0354 Metal Brush 1 unit...

Страница 4: ...Accessories Ref 0010211 Internal gasket 1 unit Ref 0019208 It contains 2 gaskets Tip cleaning set 1 unit Ref 0965970 Spanner 1 unit Ref 0780550 Glass solder collector 1 unit Ref 0812620 Long Tip Clea...

Страница 5: ...20V 0010569 230V Module Cable 1 unit Ref 0014874 Cleaning stick 1 unit Ref 0786640 Pick Place 1 unit Ref T260 A Straight Needles Set 1 unit Ref 0901546 Bent Needles Set 1 unit Ref 0861660 Cups Set 1 u...

Страница 6: ...nector P 005 Pedal connector Equipotential connector Auxiliar connector Heating element Suction Tube For tripods and extractors Heater Hose set Ref JT T1A 100V 120V JT T2A 230V Thermocouple type K Ref...

Страница 7: ...USB A connector Filter cover LED status indicators 2 8 Color TFT screen Tilt the display for easy reading DDE Features MVE Features www jbctools com 7...

Страница 8: ...ctor Equipotential connection Power Socket Control Unit Ref DDE B DDE MVE Connections Suction Filter Ref 0821830 Pneumatic Desoldering Module Ref MVE A To another peripheral Pedal Ref P 005 Stand Ref...

Страница 9: ...E A MVE A MNE A FSE A P 005 DDE B T210 A C210 AD SE T245 A C245 T470 A C245 T210 NA C210 DN SE T245 NA C245 T470 NA AP250 A C250 AP SE PA120 A C120 PA SE HT420 A C420 HT SE DS360 A C360 DS SE DR560 A...

Страница 10: ...tool Alcohol can only be used to clean the metal parts Periodically check that the metal parts of the tool and stand are clean so that the station can detect the tool status Maintain tip surface clean...

Страница 11: ...nflamable products to ignite Avoid flux coming into contact with skin or eyes to prevent irritation Be careful with the fumes produced when soldering Keep your workplace clean and tidy Wear appropriat...

Страница 12: ...DE 1B 120V 50 60Hz Input fuse 4A Output 23 5V DDE 2B 230V 50 60Hz Input fuse 2A Output 23 5V DDE 9B 100V 50 60Hz Input fuse 5A Output 23 5V Net Weight 3 8 kg 8 41 lb Dimensions 148 x 120 x 232 mm 5 83...

Страница 13: ...Pb Hg Cd Cr VI PBB PBDE O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O O O X O O O O O O GB T 26572 X GB T 26572 www jbctools com 13...

Страница 14: ...Exploded View 14...

Страница 15: ...www jbctools com 15...

Страница 16: ...lable on our website Warranty JBC s 2 year warranty covers this equipment against all manufacturing defects including the replacement of defective parts and labour Warranty does not cover product wear...

Отзывы: