manualshive.com logo in svg
background image

Premium Desoldering station 

with Electric Pump

Ref. DIS-D

www.jbctools.com

Содержание DIS-1D

Страница 1: ...Premium Desoldering station with Electric Pump Ref DIS D www jbctools com ...

Страница 2: ... 1 unit Ref MS A Module Cable 1 unit Ref 0010207 DI Control Unit 1 unit Ref DI 1D 120V DI 2D 230V DI 9D 100V Brass wool 1 unit Ref CL6210 Desoldering Iron 1 unit Ref DR560 A Stand 1 unit Ref DR SD Power cord 1 unit Ref 0009401 230V 0009417 100 120V ESD Tip Cleaner 1 unit Ref CL8499 Check our website for the corresponding manuals Also available in other languages 2 ...

Страница 3: ...f 0780840 It contains 10 filters Spanner 1 unit Ref 0780550 Glass solder collector 1 unit Ref 0002600 Metal solder collector 1 unit Ref 0812630 Tips 3 units Ref C560005 x1 Ref C560013 x1 Ref C560004 x1 Cleaning stick 1 unit Ref 0786640 Filter Box 1 unit Ref 0005966 It contains 50 filters Tip cleaning set 1 unit Ref 0965970 Long Tip Cleaning set 1 unit Ref 0781137 Premium Desoldering station with E...

Страница 4: ...ontrol Unit Ref DI 1D 120V DI 2D 230V DI 9D 100V Desoldering Iron Ref DR560 A Suction Filter Ref 0821830 Stand Ref DR SD Electric Desoldering Module Ref MS A Main Switch Fuse Equipotential connection Power Socket Module Cable Ref 0010207 4 ...

Страница 5: ...ing needs Basic working system Peripherals Control Unit Stand Tool Cartridge Range MS A MV A MN A FS500 1A FS500 2A P 005 DI D AD SD T210 A C210 T245 A C245 T470 A C245 DN SE T210 NA C210 T245 NA C245 T470 NA AP SD AP250 A C250 PA SD PA120 A C120 HT SD HT420 A C420 DS SD DS360 A C360 DR SD DR560 A C560 www jbctools com 5 ...

Страница 6: ...the tool status Maintain tip surface clean and tinned prior to storage in order to avoid tip oxidation Rusty and dirty surfaces reduce heat transfer to the solder joint Periodically check all cables and tubes Maintenance 1 Pull off the fuse holder and remove the fuse If necessary use a tool to lever it off 2 Insert the new fuse into the fuse holder and return it to the station Replace a blown fuse...

Страница 7: ...ve the appliance unattended when it is on Do not cover the ventilation grills Heat can cause inflamable products to ignite Avoid the contact of flux with skin or eyes to prevent irritation Be careful with the fumes produced when soldering Keep your workplace clean and tidy Wear appropriate protection glasses and gloves when working to avoid personal harm Utmost care must be taken with liquid tin w...

Страница 8: ...Exploded View 8 ...

Страница 9: ...www jbctools com 9 ...

Страница 10: ... 多溴二苯醚 PBDE 烙铁头 O O O O O O 手柄 O O O O O O 电源线 O O O O O O 主机 O O O O O O 电源插座 O O O O O O 保险丝 O O O O O O 主开关 O O O O O O 电位连接 X O O O O O 变压器 O O O O O O 线路板 X O O O O O O 表示该有害物质在该部件所有均质材料中的含量均在GB T 26572 规定的限量要求以下 X 表示该有害物质至少在该部件的某一均质材料中的含量超出GB T 26572 规定的限量要求 10 ...

Страница 11: ...3 54 x 4 13 x 7 09 in Output Peak Power 130W Temperature Range 90 450 C 190 840 F 5 Idle Temp Stability still air 1 5 ºC 3 ºF Tip to ground resistance 2 ohms Tip to ground voltage 2mV RMS Ambient operating temp 10 40 ºC 50 104 ºF Connections USB B Peripherals connectors MS A Weight 1 19 kg 2 63 lb Dimensions 145 x 55 x 225 mm 5 71 x 2 17 x 8 86 in Vacuum 75 570 mmHg 22 4 inHg Flow rate 9 SLPM Ambi...

Страница 12: ...ilable on our website Warranty JBC s 2 year warranty covers this equipment against all manufacturing defects including the replacement of defective parts and labour Warranty does not cover product wear or misuse In order for the warranty to be valid equipment must be returned postage paid to the dealer where it was purchased Register your warranty within 30 days of purchase in www jbctools com pro...

Отзывы: