background image

www.jbctools.com

www.jbctools.com

This product should not be thrown in the garbage. 
In accordance with the European directive 2002/96/EC, electronic equipment at the end of their life 
must be collected and returned to an authorized recycling facility.

Warranty

JBC’s 2 year warranty covers this equipment 
against all manufacturing defects, including the 
replacement of defective parts and labour.
Warranty does not cover product wear 
or its misuse. 
In order for the warranty to be valid, equipment 
must be returned, postage paid,  to the dealer 
where it was purchased.

Manual in other languages available on our website

Specifications

PSE-1A

 120V 50/60Hz. Input fuse: 6A. Output: 23.5V

PSE-2A

 230V 50/60Hz. Input fuse: 3.15A. Output: 23.5V

PSE-9A

 100V 50/60Hz. Input fuse: 8A. Output: 23.5V

-  Weight:  

4.258 Kg (9.38 lb)

-   Dimensions:  

148 x 120 x 232 mm 

-  Output Peak Power:  

160W per tool

-  Temperature Range:  

90 - 450 °C / 190 - 840 °F (±5%)

-  Idle Temp. Stability (still air):  

±1.5 ºC / ±3 ºF

-  Tip to ground resistance:  

<2 ohms

-  Tip to ground voltage:  

<2mV RMS

-  Ambient operating temp:  

10 - 40 ºC / 50 - 104 ºF

-  Connections 

USB-B / Peripherals connectors

   

RJ12 connector for Robot & DME

   

RJ12 connector for PSE 

   

RJ45 connector for LAN (Ethernet)

Complies with CE standards
ESD protected housing “skin effect”

00

13

60

6-

09

16

Содержание PSE-1A

Страница 1: ...www jbctools com Four Tool Power Supply Unit Ref PSE A ...

Страница 2: ...tems should be included Manual 1 unit Ref 0013606 Four Tool Power Supply Unit 1 unit Ref PSE 1A 120V PSE 2A 230V PSE 9A 100V www jbctools com Four Tool Power Supply Unit Ref PSE A Power Cord 1 unit Ref 0010569 230V 0013671 100 120V ...

Страница 3: ... Nitrogen Flow Regulator is required If you need to connect the MS MV MN or FS modules an adapter is required Ref IM2496 Select the equipment that best suit your soldering or desoldering needs Basic working system Peripherals Control Unit Stand Tool Cartridge Range MSE A MVE A MNE A FSE A P 005 PSE AD SD T210 A C210 T245 A C245 T470 A C245 DN SE T210 NA C210 T245 NA C245 T470 NA AP SD AP250 A C250...

Страница 4: ...its via the PSE connector RJ12 2 Connect the others PSE units as follows Increase x6 your DME s possibilities Four Tool Control Unit Ref DME A Peripherals Peripherals Peripherals up to 4 tools up to 4 tools up to 4 tools PSE PSE in PSE in PSE out PSE out Pneumatic Desoldering Module Ref MVE A Electric Desoldering Module Ref MSE A Pedal Ref P 005 ...

Страница 5: ...rals which means each tool can work with 1 module and 1 pedal at the same time Four Tool Power Supply Unit Ref PSE A Peripherals Peripherals up to 4 tools up to 4 tools up to 4 tools PSE in PSE in Peripheral PSE out PSE out PSE out Fume Extractor Switch Ref FSE A Nitrogen Flow Regulator Ref MNE A Pedal Ref P 005 ...

Страница 6: ... the same time Store specific configurations for later uses Analyze the soldering graphics of the stations on your PC and export them 1 Download the JBC Manager software and the user manual from www jbctools com manager html 2 Connect the stations via USB B or LAN Ethernet and the PC will automatically detect them 3 The notification will be displayed on the DME Control Unit or PC LAN Hub or USB HU...

Страница 7: ... or PC while updating 1 Connect the tool to the station port by means of the CHB A Converter 2 Connect your Robot system to the Robot connector RJ12 of the station DB9 RJ12 Adapater available only if necessary Ref 0013772 3 Enable the Robot option in the station settings and the notification will be displayed 4 Set your Robot s commands according to the Robot Communication Protocol available on th...

Страница 8: ...lean and tinned prior to storage in order to avoid tip oxidation Rusty and dirty surfaces reduce heat transfer to the solder joint Periodically check all cables and tubes Replace a blown fuse as follows Fuse holder Fuse holder Fuse 1 Pull off the fuse holder and remove the fuse If necessary use a tool to lever it off 2 Press the new fuse into the fuse holder and replace it in the station Replace a...

Страница 9: ...position Do not leave the appliance unattended when it is on Do not cover the ventilation grills Heat can cause inflamable products to ignite Avoid the contact of flux with skin or eyes to prevent irritation Be careful with the fumes produced when soldering Keep your workplace clean and tidy Wear appropriate protection glasses and gloves when working to avoid personal harm Utmost care must be take...

Страница 10: ...10 ...

Страница 11: ...www jbctools com 11 Exploded View ...

Страница 12: ...id to the dealer where it was purchased Manual in other languages available on our website Specifications PSE 1A 120V 50 60Hz Input fuse 6A Output 23 5V PSE 2A 230V 50 60Hz Input fuse 3 15A Output 23 5V PSE 9A 100V 50 60Hz Input fuse 8A Output 23 5V Weight 4 258 Kg 9 38 lb Dimensions 148 x 120 x 232 mm Output Peak Power 160W per tool Temperature Range 90 450 C 190 840 F 5 Idle Temp Stability still...

Отзывы: