WORK

220

time

SLEEP

220

time

HIBERNATION

room

temperature

6

INSTALLATION

HEAT MANAGEMENT

Main switch

Equipotential 

connector

CONTROL UNIT

MICRO HOT TWEEZERS

PA-A

Power Cord

Socket

JBC stations intelligently manage the tool temperature: 

Work mode:

 When the tool is used, pre-set work temperature is 350º C.

Sleep mode: 

When the tool is in the stand, the temperature goes down to 220º C.

Hibernation mode: 

After longer periods of inactivity (pre-set i.e 30 minutes), the power is cut off and 

the tool cools down to room temperature.

The advantage of this heat management is lifespan increase which ensure low cost of ownership.