![background image](http://html.mh-extra.com/html/jbc/cdeb/cdeb_instruction-manual_637013013.webp)
General Settings
Recommendations
Parameter Description
Warnings
Be careful when changing these parameters as they may reduce the tip life if not used properly.
Please follow the recommended guidelines:
Parameters
Minimum temperature
Set the minimum temperature
to work with.
Min. temp. by default is 200ºC
(392ºF). This is considered to
be a proper starting point for
leaded applications.
Maximum temperature
Set the maximum
temperature to work with.
Max. temp by default is 400°C
(750°F). This is considered
high enough to work with
most lead-free applications.
The station temperature
range is 90-450ºC
(190-840ºF). Change the
temperature limits when
working with less common
applications such as low / high
melting point soldering (HMP)
or plastics (e. g. riveting).
In most cases,
working with temperatures
over 400°C (750°F) can
damage the PCB and its
components. Even in short
time periods of tip contact
with the soldering joint, the
flux may not work properly
and could seriously reduce
tip life. If the solder joint
requires more power
(e.g. multilayered or high
dissipation boards), JBC
strongly recommends using
other aids like preheaters.
Program Version
Shows the program version
number.
PIN
Change the default security
PIN number (0105).
The PIN must be entered every
time a parameter is changed.
Sound
Enable/disable the beep
sound of the keypad.
The menu gives acces to the following menu entries:
- Language:
Select station language.
- Mode:
Choose between “Basic” and “Soldering Assistant”.
- General Settings: See table below.
- Port Settings:
See table page 14.
- Counters:
Show a register of soler joint values. Use button for more information.
- Reset:
Reset to default parameters.
- Exit:
Return to main menu.
Menu Settings
www.jbctools.com
13