background image

Tools

Recommendations

Parameter Description

Warnings

When the user changes 

the cartridge type, the 
parameter should be reset 
to 0°C/F or to the value 
needed for this cartridge. 
E.g. If a correction of 
+20°C (+36°F) is set for the 
C245966 (thick type) and 
then the user changes the 
cartridge for a C245030 
(which is thinner) without 
resetting, they would be 
working at a temperature 
of +20°C (+36°F) lower for 
the C245030 which does 
not need any temperature 
adjustment.

Temp adjust

It provides a more precise 
adjustment between the 
selected temperature and the 
actual one.

Set values within ±50°C  
(± 90°F) to achieve zero error. 
JBC strongly recommends 
the use of TID-A or TIA-A 
Thermometers to obtain 
precise readings.

Cartridge

Select the cartridge.

Temp level set

Similar to “Fix one temp” 
parameter. In this case, the 
user can set up to 3 values for 
different power requirements. 

This allows a quick change 
between 3 different tempe-
ratures. Set them according 
to the allowed values for your 
soldering applications.

N/a

14

Содержание CDE-SQA Series

Страница 1: ...INSTRUCTION MANUAL Compact Soldering Station Ref CDE SQA www jbctools com...

Страница 2: ...er Cord 1 unit Ref 0023715 120V 0023714 230V 0024092 100V Manual 1 unit Ref 0022907 CDE Control Unit 1 unit Ref CDE 1SA 120V CDE 2SA 230V CDE 9SA 100V Brass Wool 1 unit Ref CL6210 Sponge 1 unit Ref S0...

Страница 3: ...et Fuse Main Switch Pedal Connector Features and Connections Precision Purpose Handle Ref T210 A Cable Collector Quick Tip Changer Cartridge Storage Tip Cleaner Brass Wool with Antisplash Membrane and...

Страница 4: ...preventing oxidation between cleaning and rewetting Wiper Ref CL0160 A temperature resistant receptacle for removing excess solder by gently tapping or wiping If the tip is very dirty JBC recommends...

Страница 5: ...thod than brass wool Metal Brush Ref CL6220 When used carefully it provides a more thorough cleaning Sponge Ref S0354 Tapping Tap gently to remove excess solder Wiping Use the slots to remove remainin...

Страница 6: ...iron works close to vertical position Note For the different handles are different sealing plugs available Sealing Plug Replacement Before replacing the sealing plug unplug the power supply and make s...

Страница 7: ...3 Fixing Place the handpiece in the extractor and pull to remove the cartridge Place the handpiece on top of the new cartridge and press down slightly Use the holes for fixing the cartridge as follow...

Страница 8: ...d Actual Temp 290 C Delay to hiberna on 9 43 25 75 Power C210 009 50 Hiberna on Tool in the stand Actual Temp 140 C 25 75 Power C210 009 50 T210 O None 150 C 10min 0 C C210 009 325 CSel temp 325 C 25...

Страница 9: ...p temp O None 150 C 10min 0 C C245 907 Selected Cartridge Type Menu Help Information Power Indicator Selected Temperature The CDE offers an intuitive user interface which provides quick access to stat...

Страница 10: ...3s 14W s 2 4s 13W s C 95 0 5s div Ok to reset soldering Ref 20 16 12 8 4 345 Sel temp 350 C W Time Energy C245 907 Ref 2 3s 14W s C 57 0 5s div emp 350 C 45 Ref 355 350 345 340 335 C Ok to reset sold...

Страница 11: ...13W s C 95 0 5s div 0 5s div Sel temp 350 C Sel temp 350 C 1s div Max 400 d C 345 345 07 Ref Ref Ref 4 5s 50W s 355 350 345 340 335 20 16 12 8 4 W 20 16 12 8 4 W C 355 350 345 340 335 C 355 350 345 3...

Страница 12: ...s C 57 0 5s div Ok to reset soldering Ref 20 16 12 8 4 355 350 345 340 335 340 Sel temp 350 C W C Time Energy C210 009 Ref 2 3s 14W s 1 3s 8W s C 38 SOLDERING JOINT INFO 1 3 Sel temp Cartridge Time M...

Страница 13: ...lting point soldering HMP or plastics e g riveting In most cases working with temperatures over 400 C 750 F can damage the PCB and its components Even in short time periods of tip contact with the sol...

Страница 14: ...C245030 which does not need any temperature adjustment Temp adjust It provides a more precise adjustment between the selected temperature and the actual one Set values within 50 C 90 F to achieve zer...

Страница 15: ...endations Parameter Description Warnings Tools Setting these parameters to higher values will unnecessarily accelerate oxidation and shorten tip life especially when working with temperatures up to 45...

Страница 16: ...can handle by using the JBC Web Manager You can export data to another PC Register Settings Create graphs of the soldering process in real time with power and temperature data Manager Settings Change...

Страница 17: ...n can detect the tool status Maintain tip surface clean and tinned prior to storage in order to avoid tip oxidation Rusty and dirty surfaces reduce heat transfer to the solder joint Periodically check...

Страница 18: ...leave the appliance unattended when it is on Do not cover the ventilation grills Heat can cause inflamable products to ignite Avoid flux coming into contact with skin or eyes to prevent irritation Be...

Страница 19: ...D 001 Temp Accuracy 3 Using reference cartridge Temp Adjustment 50 C 90 F Through station menu settings Tip to Ground Voltage Resistance Meets and exceed ANSI ESD S20 20 2014 IPC J STD 001F Earthing F...

Страница 20: ...JBC s 2 year warranty covers this equipment against all manufacturing defects including the replacement of defective parts and labour Warranty does not cover product wear or misuse In order for the w...

Отзывы: