  To avoid condensation to be formed inside, allow the unit to adapt to the surrounding temperatures when 

bringing  it  into  a  warm  room  after  transport.  Condense  sometimes  prevents  the  unit  from  working  at  full 
performance or may even cause damages. 

  This unit is for indoor use only.  

 

Don’t place metal objects or spill liquid inside the unit. No objects filled with liquids, such as vases, shall be 
placed  on  this  appliance.  Electric  shock  or  malfunction  may  result.  If  a  foreign  object  enters  the  unit, 
immediately disconnect the mains power. 

  No naked flame sources, such as lighted candles, should be placed on the appliance. 

 

Don’t cover any ventilation openings as this may result in overheating.  

  Prevent use in dusty environments and clean the unit regularly. 

  Keep the unit away from children. 

  Inexperienced persons should not operate this device. 

  Maximum save ambient temperature is 40

°C. Don’t use this unit at higher ambient temperatures. 

  Minimum distances around the apparatus for sufficient ventilation is 5cm.  

  Always unplug the unit when it is not used for a longer time or before you start servicing. 

  The electrical installation should be carried out by qualified personal only, according to the regulations for 

electrical and mechanical safety in your country. 

  Check that the available voltage is not higher than the one stated on the rear panel of the unit. 

  The socket inlet shall remain operable for disconnection from the mains. 

  The power cord should always be in perfect condition. Switch the unit immediately off when the power cord 

is squashed or damaged.  

  Never let the power-cord come into contact with other cables! 

  When the power switch is in OFF position, this unit is not completely disconnected from the mains! 

  This CLASS I appliance must  be connected to MAINS socket outlet with a protective earth connection  in 

order comply with safety regulations. 

  In  order  to  prevent  electric  shock,  do  not  open  the  cover.  Apart  from  the  mains  fuse  there  are  no  user 

serviceable parts inside. 

 

Never

 repair a fuse  or bypass the fuse holder. 

Always

 replace a damaged fuse  with a fuse of the same 

type and electrical specifications! 

  In the event of serious operating problems, stop using the appliance and contact your dealer immediately. 

  Please use the original packing when the device is to be transported. 

  Due to safety reasons it is prohibited to make unauthorized modifications to the unit. 

 

INSTALLATION GUIDELINES:

 

  Install the unit in a well-ventilated location where it will not be exposed to high temperatures or humidity. 

  Placing and using the unit for long periods near heat-generating sources such as amplifiers, spotlights, etc. 

will affect its performance and may even damage the unit. 

  The unit can be mounted in 19-inch racks. Attach the unit using the 4 screw holes on the front panel. Be 

sure  to  use  screws  of  the  appropriate  size.  (screws  not  provided)  Take  care  to  minimize  shocks  and 
vibrations during transport. 

  When  installed  in  a  booth  or  flight  case,  please  make  sure  to  have  good  ventilation  to  improve  heat 

evacuation of the unit. 

  To avoid condensation to be formed inside, allow the unit to adapt to the surrounding temperatures when 

bringing  it  into  a  warm  room  after  transport.  Condense  sometimes  prevents  the  unit  from  working  at  full 
performance. 

 
CLEANING THE APPLIANCE:

 

Clean by wiping with a polished cloth slightly dipped  with water. Avoid getting water inside the unit. Do not 
use volatile liquids such as benzene or thinner which will damage the unit. 

 

Содержание XO 2.4 Mk2

Страница 1: ...Other languages can be downloaded from WWW JB SYSTEMS EU ENGLISH Operation Manual Version 1 0 ...

Страница 2: ......

Страница 3: ...ms caused by disregarding this user manual Keep this booklet in a safe place for future consultation If you sell the fixture be sure to add this user manual To protect the environment please try to recycle the packing material as much as possible Check the contents Check that the carton contains the following items User manual Power Cable XO2 4 Mk2 unit SAFETY INSTRUCTIONS This appliance is intend...

Страница 4: ...h other cables When the power switch is in OFF position this unit is not completely disconnected from the mains This CLASS I appliance must be connected to MAINS socket outlet with a protective earth connection in order comply with safety regulations In order to prevent electric shock do not open the cover Apart from the mains fuse there are no user serviceable parts inside Never repair a fuse or ...

Страница 5: ...l 1 MID and HIGH frequencies on the Channel 2 4 X10 LED X10 LED off you can control the x over frequency from 45Hz to 960Hz X10 LED on you can control the x over frequency from 450Hz to 9 6kHz 5 LOW MID Output Controls the In Stereo mode LOW frequency output level from to 6dB both channels In Mono mode LOW frequency output level from to 6dB on Channel 1 MID frequency output level from to 6dB on Ch...

Страница 6: ...unds of various other components in your setup As a result the hum noises will disappear 13 XLR Inputs Balanced inputs using XLR cables When you work in Mono Mode you only have to connect an XLR cable on Channel one 14 LOW MID XLR Output Balanced outputs using XLR cables In Stereo Mode When you work in Normal mode see number 17 for more information you have to connect an XLR cable to Channels 1 an...

Страница 7: ...ed by the manufacturer Power Supply 115 VAC 60Hz or 230 VAC 50Hz Fuse 20mm glass fuse 250V 500mA slow Frequency response 20Hz to 25kHz 1 dB THD noise 0 006 S N Ratio IHF A 95dB 1kHz Crossover Frequencies 45 960 Hz normal mode 450 9600 Hz x10 mode Filter type 18dB Octave Low Cut Filters 40Hz Dimensions 483 W x 44 H x 146 D mm Weight 2kg Every information is subject to change without prior notice Yo...