JB Systems Sunbar Combi Скачать руководство пользователя страница 11

ENGLISH 

USER MANUAL 

 

 
JB SYSTEMS

®

 

9/10 

SUNBAR COMBI 

193-215 

Pattern 2

 

216-238 

Pattern 3

 

239-255 

Pattern 4

 

CH 15 

000-243 

Speed (slow to fast) 

Color Pattern Speed 

244-255 

Music controlled  

CH 16

 

000-009

 

Black-Out

 

WHITE Beam 

Pattern Selection 

010-022 

Pattern 1 

023-035 

Pattern 2

 

036-048 

Pattern 3

 

049-061 

Pattern 4

 

062-074 

Pattern 5

 

075-087 

Pattern 6

 

088-100 

Pattern 7

 

101-113 

Pattern 8

 

114-126 

Pattern 9

 

127-139 

Pattern 10

 

140-152 

Pattern 11

 

153-165 

Pattern 12

 

166-178 

Pattern 13

 

179-191 

Pattern 14

 

192-204 

Pattern 15

 

205-217 

Pattern 16

 

218-230 

Pattern 17

 

231-255 

Random Pattern

 

CH 17 

000-243 

Speed (slow to fast) 

Beam Pattern Speed 

244-255 

Music controlled  

 

Extra functions in the menu 

  Press the [MENU] button until the display shows [SYS]. 

  Press the [ENTER] button if you want to enter this part of the menu with extra options. 

  Use the [UP/DOWN] buttons to browse the extra functions in this System menu 

o

 

[rSEt]

 

= Factory Reset

. This function can be used to reset all the settings of the unit to the 

original factory settings 

 

Just press the [ENTER] button to reset the unit. 

o

 

 [binU] = Beam inversion 

With this option you can invert the flow of the beam effects. 

 

Press the [ENTER] button to enter the option settings 

 

Use the [UP / DOWN] button to select the desired mode: 

 

[on] = inverted flow 

 

[oFF] = normal flow.

 

 

MAINTENANCE

 

  Make sure the area below the installation place is free from unwanted persons during servicing. 

  Switch off the unit, unplug the mains cable and wait until the unit has been cooled down. 

During inspection the following points should be checked: 

  All  screws  used  for  installing  the  device  and  any  of  its  parts  should  be  tightly  fastened  and  may  not  be 

corroded. 

  Housings,  fixations  and  installations  spots  (ceiling,  truss,  suspensions)  should  be  totally  free  from  any 

deformation. 

  When an optical lens is visibly damaged due to cracks or deep scratches, it must be replaced. 

  The  mains  cables  must  be  in  impeccable  condition  and  should  be  replaced  immediately  when  even  a 

small problem is detected. 

  In order  to  protect  the  device  from  overheat the  cooling  fans  (if  any)  and  ventilation  openings  should  be 

cleaned monthly. 

Содержание Sunbar Combi

Страница 1: ......

Страница 2: ......

Страница 3: ...ct to warranty The dealer will not accept responsibility for any resulting defects or problems caused by disregarding this user manual Keep this booklet in a safe place for future consultation If you sell the fixture be sure to add this user manual Check the contents Check if the packing contains the following items Operating instructions SUNBAR COMBI Mains cable SAFETY INSTRUCTIONS CAUTION To red...

Страница 4: ... when it is not used for a longer time or before to start servicing The electrical installation should be carried out by qualified persons only according to the regulations for electrical and mechanical safety in your country Check that the available voltage is not higher than the one stated on the unit The power cord should always be in perfect condition Switch the unit immediately off when the p...

Страница 5: ... specifications 10 GROUND CONNECTOR if extra grounding is required the connection can be done here 11 MENU button used to browse the different functions in the menu 12 UP button to increase the values shown on the display 13 DOWN button to lower the values shown on the display 14 ENTER button used to confirm your choice or to enter the setup mode of a function OVERHEAD RIGGING Important The instal...

Страница 6: ...rammed sequence Select this mode when only 1 unit is used standalone or when the unit is placed as the first master unit in a chain with several units in Master Slave mode see below Automatic show mode this is how to select one of the preprogrammed shows Press the MENU button until the display shows Aut Press the ENTER button to enter the setup Use the UP and DOWN buttons to choose the type of aut...

Страница 7: ...D VIA DMX The unit can be controlled by any standard DMX controller in 5 different DMX modes 1 4 11 12 and 17 channels Connect the DMX input of the Sunbar to the DMX output of the previous unit in the chain or directly to the DMX output of your controller Press the MENU button until the display shows dMH Press the ENTER button to enter this option The actual DMX address is shown on the display Pre...

Страница 8: ...ue 101 123 Pink 124 146 Cyan 147 169 White 170 192 Pattern 1 193 215 Pattern 2 216 238 Pattern 3 239 255 Pattern 4 CH 2 000 243 Speed slow to fast Color Pattern Speed 244 255 Music controlled CH 3 000 009 Black Out WHITE Pattern Selection 010 022 Pattern 1 023 035 Pattern 2 036 048 Pattern 3 049 061 Pattern 4 062 074 Pattern 5 075 087 Pattern 6 088 100 Pattern 7 101 113 Pattern 8 114 126 Pattern 9...

Страница 9: ...ection 010 031 Red 032 054 Green 055 077 Yellow 078 100 Blue 101 123 Pink 124 146 Cyan 147 169 White 170 192 Pattern 1 193 215 Pattern 2 216 238 Pattern 3 239 255 Pattern 4 CH 9 000 243 Speed slow to fast Color Pattern Speed 244 255 Music controlled CH 10 000 009 Black Out WHITE Pattern Selection 010 022 Pattern 1 023 035 Pattern 2 036 048 Pattern 3 049 061 Pattern 4 062 074 Pattern 5 075 087 Patt...

Страница 10: ...nnel DMX Mode Channel Value Function CH 1 000 255 Red Manual Color Control CH 2 000 255 Green CH 3 000 255 Blue CH 4 000 255 Dimmer CH 5 000 009 NO strobe 010 083 Strobe 084 163 Random Strobe 164 243 On Off effect 244 255 Sound Controlled CH 6 000 255 Dimmer LED 1 Beam Control CH 7 000 255 Dimmer LED 2 CH 8 000 255 Dimmer LED 3 CH 9 000 255 Dimmer LED 4 CH 10 000 255 Dimmer LED 5 CH 11 000 255 Dim...

Страница 11: ...t all the settings of the unit to the original factory settings Just press the ENTER button to reset the unit o binU Beam inversion With this option you can invert the flow of the beam effects Press the ENTER button to enter the option settings Use the UP DOWN button to select the desired mode on inverted flow oFF normal flow MAINTENANCE Make sure the area below the installation place is free from...

Страница 12: ... personnel SPECIFICATIONS This unit is radio interference suppressed This product meets the requirements of the current European and national guidelines Conformity has been established and the relevant statements and documents have been deposited by the manufacturer This device was designed to produce decorative effect lighting and is used in light show systems Mains Input 100 230Vac 50 60Hz Power...

Отзывы: