background image

ENGLISH 

 

OPERATION MANUAL 

 

 

JB SYSTEMS

®

 

4/24 

PSA-series 

RIGGING 

 

Important:

 

The  installation  must  be  carried  out  by  qualified  service  personal  only.  Improper 

installation  can  result  in  serious  injuries  and/or  damage  to  property.   Overhead  rigging  requires 
extensive  experience!  Working  load  limits  should  be  respected,  certified  installation  materials 
should be used, the installed device should be inspected regularly for safety.

 

  Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging 

and servicing. 

  The cabinet should be installed out of reach of people and outside areas where persons may walk by or 

be seated. 

  Before  rigging  make  sure  that  the  installation  area  can  hold  a  minimum  point  load  of  10times  the 

cabinet

’s weight. 

  Always  use  a  certified  safety  cable  that  can  hold  12  times  the  weight  of  the  cabinet  while  installing  the 

unit.  This  secondary  safety  attachment  should  be  installed  in  a  way  that  no  part  of  the  installation  can 
drop more than 20cm if the main attachment fails. 

  The cabinet should be well fixed; a free-swinging mounting is dangerous and may not be considered! 

  The operator has to make sure that the safety-relating and machine-technical installations are approved 

by  an  expert  before  using  them for  the  first  time. The  installations  should  be  inspected  every  year  by  a 
skilled person to be sure that safety is still optimal. 

 

  The PSA-cabinets have 4 rigging points using M8 inserts. 

These can be used to suspend (fly) the cabinet in the air. 
For  this  purpose  you  can  use  heavy  duty  eyebolts  with 
metric M8 thread. In most cases 2 cables will be attached 
to the top and one is used to pull up the back.  

  Anyway  always  take  special  care  when  the  cabinets  are 

suspended. This is potentially dangerous and should only 
be  carried  out  by  technicians  who  have  perfect 
knowledge  of  the  techniques  and  regulations  of  rigging 
speakers!  

 

SPECIFICATIONS 

MODEL 

PSA-12 

PSA-15 

Amplifier Tweeter 

35Wrms 

55Wrms 

Amplifier Woofer 

165Wrms 

245Wrms 

Freq. Resp. (+/-3dB) 

45 

– 20.000Hz 

40 

– 20.000Hz 

THD (1kHz / 1W) 

0,10% 

0,10% 

Input Sensitivity line 

1V 

1V 

Input Sensitivity micro 

15mV 

15mV 

Input impedance 

20 kohm 

20 kohm 

S/R ratio (mic off) 

>85dB 

>85dB 

EQ low 

+/-12dB @ 100Hz 

+/-12dB @ 100Hz 

EQ high 

+/-12dB @ 10kHz 

+/-12dB @ 10kHz 

Cooling 

natural air cooling 

natural air cooling 

Microphone input 

Bal/unbal XLR/Jack 

Bal/unbal XLR/Jack 

Line input 

Bal/unbal XLR 3pin 

Bal/unbal XLR 3pin 

Line outputs 

Bal/unbal XLR 3pin 

Bal/unbal XLR 3pin 

Fuse (5x20mm) 

F4A / 250V 

F5A / 250V 

Power supply 

115Vac/60Hz 230Vac/50Hz 

115Vac/60Hz 230Vac/50Hz

 

Dimensions HxWxD (mm) 

588 x 431 x 310 

680 x 470 x 400 

Weight (kg) 

17 

23,3 

 

Every information is subject to change without prior notice 

You can download the latest version of this user manual on our website: www.beglec.com

  

Содержание PSA-12

Страница 1: ......

Страница 2: ......

Страница 3: ...woofer 1 75 compression driver Balanced MIC LINE inputs with level PSA 15 has 2 mic inputs Balanced LINE output Treble Bass controls Master volume Blue power LED on the front panel Built in M8 Rigging...

Страница 4: ...he available voltage is not higher than the one stated on the rear panel of the unit The socket inlet shall remain operable for disconnection from the mains The power cord should always be in perfect...

Страница 5: ...ike for example CD player tuner MP3 player Attention although the cinch input is stereo the signal will be converted to mono inside the speaker 7 MASTER LEVEL Used to set the overall volume of the amp...

Страница 6: ...irst time The installations should be inspected every year by a skilled person to be sure that safety is still optimal The PSA cabinets have 4 rigging points using M8 inserts These can be used to susp...

Страница 7: ...1 75 Entr e s MIC sym trique entr e LINE avec r glage du niveau le PSA 15 est dot de 2 entr es microphone Sortie LINE sym trique Boutons de r glage pour les sons aigus graves volume principal LED bleu...

Страница 8: ...endant une longue p riode et avant chaque entretien L installation lectrique doit tre effectu e par du personnel qualifi conform ment la r glementation en mati re de s curit lectrique et m canique dan...

Страница 9: ...glez toujours cette commande sur le niveau minimum avant de connecter toute source audio 6 ENTR E CONDUITE Cette entr e accept e des signaux audio sym triques XLR 3 broches et non sym triques RCA cin...

Страница 10: ...un c ble de s curit certifi qui pourrait supporter 12 fois le poids de l enceinte lors de l installation de l appareil Ce support de suspension de s curit secondaire doit tre install de mani re ce qu...

Страница 11: ...ent Refroidissement par air naturel Refroidissement par air naturel Entr e microphone XLR jack sym trique non sym trique XLR jack sym trique non sym trique Entr e conduite XLR sym trique non sym triqu...

Страница 12: ...15 heeft 2 mic ingangen Gebalanceerde LIJN uitgangen Hoge Tonen Lage Tonen bedieningen Master volume Blauwe aan uit LED op het voorpaneel Ingebouwde M8 Ophijspunten Ingebouwde 35mm steunadapter Steun...

Страница 13: ...onderhoud te beginnen De elektrische installatie dient alleen door gekwalificeerd personeel te worden uitgevoerd in overeenstemming met de voorschriften voor elektrische en mechanische veiligheid in...

Страница 14: ...als MIC 1 ingang 1 4 MIC 2 NIVEAU alleen beschikbaar op PSA 15 dezelfde functionaliteit als MIC 1 NIVEAU 2 5 LIJNNIVEAU Gebruikt om het ingangsniveau van de lijningang 6 in te stellen Stel de bedienin...

Страница 15: ...dersteunen Gebruik altijd een gecertificeerde veiligheidskabel die 12 keer het kabinetgewicht kan dragen voordat u het apparaat installeert Deze secundaire veiligheidsbevestiging dient op een zodanige...

Страница 16: ...2dB 10kHz 12dB 10kHz Koeling natuurlijke luchtkoeling natuurlijke luchtkoeling Microfooningang Gebal ongebal XLR Jack Gebal ongebal XLR Jack Lijningang Gebal ongebal XLR 3 polig Gebal ongebal XLR 3 po...

Страница 17: ...Symmetrische MIC u LINE Eing nge mit Pegelregler PSA 15 verf gt ber 2 Mikrofoneing nge Symmetrischer LINE Ausgang H hen Bass Regler und Hauptlautst rke Blaue Betriebs LED auf der Vorderseite Integrier...

Страница 18: ...et wird Die elektrische Installation darf nur von qualifiziertem Personal unter Beachtung der Vorschriften zur elektrischen und mechanischen Sicherheit in Ihrem Land durchgef hrt werden Vergewissern S...

Страница 19: ...Eingang 1 4 MIC 2 PEGEL Nur bei PSA 15 verf gbar Dieselbe Funktionalit t wie der MIC 1 Eingangspegelregler 2 5 LINE PEGEL Stellt die Lautst rke des Line Eingangs 6 ein Stellen Sie den Regler vor dem A...

Страница 20: ...lationsbereich wenigstens das 10 fache Ger tegewicht aufnehmen kann Zur Aufh ngung stets ein zugelassenes Sicherheitskabel verwenden das das 12 fache Boxgewicht aushalten kann Eine zweite Sicherungsau...

Страница 21: ...EQ H hen 12 dB bei 10 kHz 12 dB bei 10 kHz K hlung Nat rliche Luftzirkulation Nat rliche Luftzirkulation Mikrofoneingang Sym Unsym XLR Buchse Sym Unsym XLR Buchse Line Eingang Sym Unsym XLR 3 polig S...

Страница 22: ...adas MIC LINE con nivel el PSA 15 tiene 2 entradas 2 mic Salida LINE balanceada Controles de agudos y graves volumen maestro LED azul de encendido POWER en el panel frontal Puntos de enganche M8 integ...

Страница 23: ...se le vaya a dar servicio La instalaci n el ctrica debe realizarla solamente personal cualificado de acuerdo con las regulaciones para la seguridad el ctrica y mec nica de su pa s Compruebe que la ten...

Страница 24: ...del a entrada del micr fono 1 3 ENTRADA MIC 2 solo disponible en el PSA 15 la misma funcionalidad que la entrada de MIC 1 1 4 NIVEL MIC 2 solo disponible en el PSA 15 la misma funcionalidad que el ni...

Страница 25: ...bre personas caminando o sentadas Antes de suspender el altavoz cerci rese que la instalaci n tenga puntos de sujeci n que soporten una carga 10 veces el peso del altavoz Utilice siempre un aparejo ca...

Страница 26: ...Alto 12dB 10kHz 12dB 10kHz Refrigeraci n natural por aire natural por aire Entrada de micr fono Bal Desbal XLR Clavija Bal Desbal XLR Clavija Entrada de L nea Bal Desbal XLR 3 pines Bal Desbal XLR 3...

Страница 27: ......

Страница 28: ...W JB SYSTEMS EU Copyright 2014 by BEGLEC NV t Hofveld 2C B1702 Groot Bijgaarden Belgium Reproduction or publication of the content in any manner without express permission of the publisher is prohibit...

Отзывы: