JB Systems INTRUDER Скачать руководство пользователя страница 4

ENGLISH 

USER MANUAL 

 

JB SYSTEMS

®

 

2/11 

INTRUDER 

 

SAFETY INSTRUCTIONS: 

 

  To protect the environment, please try to recycle the packing material as much as possible. 

  To prevent fire or shock hazard, do not expose this appliance to rain or moisture. 

  To avoid condensation to be formed inside, allow the unit to adapt to the surrounding temperatures when 

bringing  it  into  a  warm  room  after  transport.  Condense  sometimes  prevents  the  unit  from  working  at  full 
performance or may even cause damages. 

  This unit is for indoor use only.  

 

Don’t place metal objects or spill liquid inside the unit. Electric shock or malfunction may result. If a foreign 
object enters the unit, immediately disconnect the mains power. 

  Locate the fixture in a well ventilated spot, away from any flammable materials and/or liquids. The fixture 

must be fixed at least 50cm from surrounding walls. 

 

Don’t cover any ventilation openings as this may result in overheating.  

  Prevent use in dusty environments and clean the unit regularly. 

  Keep the unit away from children. 

  Inexperienced persons should not operate this device. 

 

Maximum safe ambient temperature is 40°C. Don’t use this unit at higher ambient temperatures. 

  Make  sure  the  area  below  the  installation  place  is  free  from  unwanted  persons  during  rigging, de-rigging 

and servicing. 

  Allow the device about 10 minutes to cool down before to start servicing. 

  Always unplug the unit when it is not used for a longer time or before to start servicing. 

  The electrical installation should be carried out by qualified personal only, according to the regulations for 

electrical and mechanical safety in your country. 

  Check that the available voltage is not higher than the one stated on the unit. 

  The power cord should always be in perfect condition. Switch the unit immediately off when the power cord 

is squashed or damaged.  It must be replaced  by the  manufacturer, its service agent or similarly qualified 
persons in order to avoid a hazard. 

  Never let the power-cord come into contact with other cables! 

  This fixture must be earthed in order to comply with safety regulations. 

 

Don’t connect the unit to any dimmer pack. 

  Always use an appropriate and certified safety cable when installing the unit. 

  In order to prevent electric shock, do not open the cover. There are no user serviceable parts inside. 

 

Never

 repair a fuse  or bypass the fuse holder. 

Always

 replace a damaged fuse  with a fuse of the same 

type and electrical specifications! 

  In the event of serious operating problems, stop using the fixture and contact your dealer immediately. 

  The housing and the lenses must be replaced if they are visibly damaged. 

  Please use the original packing when the device is to be transported. 

  Due to safety reasons it is prohibited to make unauthorized modifications to the unit. 

Important: 

Never look directly into the light source! Don’t use the effect in the presence of persons suffering 

from epilepsy. 

 

CAUTION:

  To  reduce  the  risk  of  electric  shock,  do  not  remove 

the  top  cover.  No  user-serviceable  parts  inside.  Refer  servicing 
to qualified service personnel only. 

 

The  lightning flash with arrowhead symbol within the  equilateral triangle  is intended to alert  the 
use or the presence of un-

insulated “dangerous voltage” within the product’s enclosure that may 

be of sufficient magnitude to constitute a risk of electric shock. 

 

The exclamation point within the equilateral triangle is intended to alert the user to the presence 
of  important  operation  and  maintenance  (servicing)  instructions  in  the  literature  accompanying 
this appliance. 

 

This symbol means: indoor use only

 

 

This symbol means: Read instructions

 

 

CAUTION: 

Do not stare at operating lamp.  

May be harmful to the eyes. 

Содержание INTRUDER

Страница 1: ...Other languages can be downloaded from WWW JB SYSTEMS EU ENGLISH Operation Manual Version 1 0 INTRUDER...

Страница 2: ......

Страница 3: ...W RGBW LEDs are driven at 30W for excellent cooling and long lasting performance of the LEDs Color LCD display for easy menu navigation 3p XLR connectors for DMX in and output PowerCon compatible powe...

Страница 4: ...perfect condition Switch the unit immediately off when the power cord is squashed or damaged It must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid...

Страница 5: ...ed a free swinging mounting is dangerous and may not be considered Don t cover any ventilation openings as this may result in overheating The operator has to make sure that the safety relating and mac...

Страница 6: ...o browse the menu Select the desired function with the ENTER button Use buttons to change the mode or value Once the required mode or value is selected press the ENTER button to select Level 1 Level 2...

Страница 7: ...und activates sound controlled effects Master activates master mode Once the correct option shows on the display press the ENTER button to confirm Fixture Pan Invert Used to select if the PAN movement...

Страница 8: ...cess the different functions in the menu Press the buttons until the desired function is showing on the display Press the ENTER button A list with all the functions will appear Press the buttons to se...

Страница 9: ...ojector Press the MENU button to access the different functions in the menu Press the buttons until the desired function is showing on the display Press the ENTER button the display shows the firmware...

Страница 10: ...pin is more popular because these cables are compatible with balanced audio cables Pin layout XLR 3pin Pin1 GND Pin2 Negative signal Pin3 Positive signal To prevent strange behavior of the light effec...

Страница 11: ...r 000 255 7 Dimmer fine 000 255 7 8 7 Strobe 000 003 Closed 004 010 Open 011 103 Strobe slow to fast 104 107 Open 108 207 Pulse strobe slow to fast 208 212 Open 213 225 Random strobe slow 226 238 Rand...

Страница 12: ...visibly damaged due to cracks or deep scratches it must be replaced The mains cables must be in impeccable condition and should be replaced immediately when even a small problem is detected In order t...

Страница 13: ...er consumption 280 Watt max Fuse 250V 5A Slow blow 20mm glass Power connections Lockable Power Connector 10A Neutrik PowerCon compatible DMX connections 3pin XLR male female DMX channels used 7ch 11ch...