Thank you for buying this JB Systems

®

product. To take full advantage of all possibilities, please read these

operating instructions very carefully.

FEATURES

This unit is radio-interference suppressed. This appliance meets the requirements of the current European
and national guidelines. Conformity has been established and the relevant statements and documents have
been deposited by the manufacturer.

Professional 2-channel amplifier with built-in active crossover.

Very compact housing, only 2U (88mm) high

Oversized power supply guarantees a powerful bass reproduction

Built-in active crossovers: no need for separate crossover units to setup an active system.

Each channel equipped with a 24dB/octave crossover: adjustable crossover point (90~250Hz) and 3
operation modes: HPF (high pass filter) + LPF (low pass filter) + OFF (no filter)

Two amplifier modes: stereo and bridge

Peak limiters can be switched on/off

Soft start power supply

Very efficient cooling

DC fault protection

High temperature protection

Overload and short circuit protections

Balanced inputs with combo connectors (jack + XLR)

XLR-outputs: daisy chaining of several amplifiers

3 Speakon

®

outputs: left + right ch bridge

3 models with different output power available.

BEFORE USE

Before you start using this unit, please check if there’s no transportation damage. Should there be any, do
not use the device and consult your dealer first.

Important:

This device left our factory in perfect condition and well packaged. It is absolutely necessary

for the user to strictly follow the safety instructions and warnings in this user manual. Any damage caused
by mishandling is not subject to warranty. The dealer will not accept responsibility for any resulting defects
or problems caused by disregarding this user manual.

Keep this booklet in a safe place for future consultation. If you sell the fixture, be sure to add this user
manual.

To protect the environment, please try to recycle the packing material as much as possible.

Check the contents:

Check that the carton contains the following items:

User manual

D2-amplifier

SAFETY INSTRUCTIONS:

CAUTION

CAUTION:

To reduce the risk of electric shock, do not

remove the top cover. No user-serviceable parts inside.
Refer servicing to qualified service personnel only.

The lightning flash with arrowhead symbol within the equilateral triangle is intended to alert the
use or the presence of un-insulated “dangerous voltage” within the product’s enclosure that may
be of sufficient magnitude to constitute a risk of electric shock.

ENGLISH

OPERATION MANUAL

JB SYSTEMS

®

2/41

D2-900 ~ D2-1200 ~ D2-1500

To prevent fire or shock hazard, do not expose this appliance to rain or moisture.

To avoid condensation to be formed inside, allow the unit to adapt to the surrounding temperatures when
bringing it into a warm room after transport. Condense sometimes prevents the unit from working at full
performance or may even cause damages.

This unit is for indoor use only.

Don’t place metal objects or spill liquid inside the unit. No objects filled with liquids, such as vases, shall be
placed on this appliance. Electric shock or malfunction may result. If a foreign object enters the unit,
immediately disconnect the mains power.

No naked flame sources, such as lighted candles, should be placed on the appliance.

Don’t cover any ventilation openings as this may result in overheating.

Prevent use in dusty environments and clean the unit regularly.

Keep the unit away from children.

Inexperienced persons should not operate this device.

Maximum save ambient temperature is 40°C. Don’t use this unit at higher ambient temperatures.

Minimum distances around the apparatus for sufficient ventilation is 5cm.

Always unplug the unit when it is not used for a longer time or before you start servicing.

The electrical installation should be carried out by qualified personal only, according to the regulations for
electrical and mechanical safety in your country.

Check that the available voltage is not higher than the one stated on the rear panel of the unit.

The socket inlet shall remain operable for disconnection from the mains.

The power cord should always be in perfect condition. Switch the unit immediately off when the power cord
is squashed or damaged. It must be replaced by the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.

Never let the power-cord come into contact with other cables!

When the power switch is in OFF position, this unit is not completely disconnected from the mains!

This appliance must be earthed to in order comply with safety regulations.

In order to prevent electric shock, do not open the cover. Apart from the mains fuse there are no user
serviceable parts inside.

Never

repair a fuse or bypass the fuse holder.

Always

replace a damaged fuse with a fuse of the same

type and electrical specifications!

In the event of serious operating problems, stop using the appliance and contact your dealer immediately.

Please use the original packing when the device is to be transported.

Due to safety reasons it is prohibited to make unauthorized modifications to the unit.

INSTALLATION GUIDELINES:

Install the unit in a well-ventilated location where it will not be exposed to high temperatures or humidity.

Placing and using the unit for long periods near heat-generating sources such as amplifiers, spotlights, etc.
will affect its performance and may even damage the unit.

The unit can be mounted in 19-inch racks. Attach the unit using the 4 screw holes on the front panel. Be
sure to use screws of the appropriate size. (screws not provided)

Take care to minimize shocks and vibrations during transport.

When installed in a booth or flight case, please make sure to have good ventilation to improve heat
evacuation of the unit.

To avoid condensation to be formed inside, allow the unit to adapt to the surrounding temperatures when
bringing it into a warm room after transport. Condense sometimes prevents the unit from working at full
performance.

CLEANING THE UNIT:

Clean by wiping with a cloth slightly dipped with water. Avoid getting water inside the unit.
Do not use volatile liquids such as benzene or thinner which will damage the unit.

The exclamation point within the equilateral triangle is intended to alert the user to the presence of
important operation and maintenance (servicing) instructions in the literature accompanying this
appliance.

This symbol means: indoor use only

This symbol means: Read instructions

Содержание D2-series

Страница 1: ... the content in any manner without express permission of the publisher is prohibited D2 SERIES AMPLIFIERS Version 1 0 The Power Source for DJ s Operation Manual Mode d emploi Gebruiksaanwijzing Bedienungsanleitung Manual de instrucciones Manual do utilizador EN FR NL DU ES PT ...

Страница 2: ...t toestel en de gebruikte batterijen op een milieuvriendelijke manier conform de in uw land geldende voorschriften DU ENTSORGUNG DES GERÄTS Entsorgen Sie das Gerät und die Batterien auf umweltfreundliche Art und Weise gemäß den Vorschriften Ihres Landes ES DESHACERSE DEL APARATO Reciclar el aparato y pilas usadas de forma ecologica conforme a las disposiciones legales de su pais PT COMO DESFAZER S...

Страница 3: ...ric shock or malfunction may result If a foreign object enters the unit immediately disconnect the mains power No naked flame sources such as lighted candles should be placed on the appliance Don t cover any ventilation openings as this may result in overheating Prevent use in dusty environments and clean the unit regularly Keep the unit away from children Inexperienced persons should not operate ...

Страница 4: ...ing the amplifier off the protect led turns on for a short time 7 HP FILTER LED Indicates that the high pass filter HPF is switched on for this channel left and right channels have their own HPF LED Please refer to numbers 18 and 20 to learn more about this filter 8 LP FILTER LED Indicates that the low pass filter LPF is switched on for this channel left and right channels have their own LPF LED P...

Страница 5: ...els of amplifier A for the top cabinets and both channels of amplifier B for the subwoofer s Both amplifiers receive a normal stereo audio signal Connect the stereo audio signal to the inputs of both amplifiers use a short XLR cable to daisy chain the inputs of both amplifiers Put the mode switch of both amplifiers 13 to stereo Connect the top cabinets to the outputs 15 of amplifier A Connect the ...

Страница 6: ...rieur uniquement Ne pas insérer d objet métallique ou verser un liquide dans l appareil Aucun objet rempli de liquides tels que des vases ne sera placé sur cet appareil Risque de choc électrique ou de dysfonctionnement Si un corps étranger est introduit dans l unité déconnectez immédiatement de la source d alimentation Aucune source de flamme nue telle que les bougies allumées ne devrait être plac...

Страница 7: ... à ce que le niveau sonore que vous désirez soit atteint Assurez vous que personne ne peut toucher les potentiomètres de gain de votre amplificateur Vous venez de régler le niveau maximal que le DJ peut produire Vos voisins seront contents dans quelques cas le DJ ne le sera pas Remarque En mode Bridge seul le contrôle du canal gauche est utilisé pour régler la sensibilité d entrée 3 SIGNAL LED Le ...

Страница 8: ...ume désiré FRANCAIS MODE D EMPLOI JB SYSTEMS 12 41 D2 900 D2 1200 D2 1500 Utilisation avec les filtres de fréquence pour obtenir un système stéréo actif Veuillez noter que quand on utilise un système actif il est nécessaire d avoir 2 amplis pour travailler en stéréo Il y a deux options différentes pour connecter les amplis Option 1 un ampli par côté pour les sorties des hautes et basses fréquences...

Страница 9: ...ldig te lezen voor U begint het apparaat te gebruiken KARAKTERISTIEKEN In dit apparaat is radio interferentie onderdrukt Dit product voldoet aan de gangbare Europese en nationale voorschriften Het is vastgesteld dat het apparaat er zich aan houdt en de desbetreffende verklaringen en documenten zijn door de fabrikant afgegeven Professionele 2 kanaals versterker met ingebouwde actieve cross over Zee...

Страница 10: ...ties aan het toestel aan te brengen CAUTION WAARSCHUWING Om het risico op elektrocutie zoveel mogelijk te vermijden mag u nooit de behuizing verwijderen Er bevinden zich geen onderdelen in het toestel die u zelf kan herstellen Laat de herstellingen enkel uitvoeren door een bevoegde technicus De bliksempijl die zich in een gelijkbenige driehoek bevindt is bedoeld om u te wijzen op het gebruik of de...

Страница 11: ...dskabels van goede kwaliteit Bedrading van de XLR aansluiting PIN1 GND PIN2 pos PIN3 GND verbonden met pin PIN1 Bedrading van de JACK aansluiting Huls GND TIP pos RING GND verbonden met de huls NEDERLANDS HANDLEIDING JB SYSTEMS 18 41 D2 900 D2 1200 D2 1500 12 XLR LINK UITGANGEN In vele gevallen heeft U veel meer vermogen nodig dan wat één versterker kan leveren In deze gevallen kunnen de LINK uitg...

Страница 12: ...er B Sluit de gain controleknoppen 2 van beide versterkers Zet beide versterkers aan 9 Open de gain controleknoppen 2 van versterker A tot u het gewenste niveau bereikt Open de gain controleknoppen 2 van versterker B tot u een mooie balans tussen de topkasten en de subwoofer s verkrijgt Regel de cross over punten van beide versterkers opmerking indien u een zeer krachtige subwoofer gebruikt dan ku...

Страница 13: ...äts gelangen lassen Keine mit Flüssigkeit gefüllten Gegenstände z B Vasen auf das Gerät stellen Kurzschluss oder Fehlfunktion können die Folge sein Falls es doch einmal vorkommen sollte bitte sofort Netzstecker ziehen und vom Stromkreis trennen Offene Brandquellen wie z B brennende Kerzen sollten nicht auf das Gerät gestellt werden Ventilationsöffnungen nicht abdecken da Überhitzungsgefahr Nicht i...

Страница 14: ...vorhanden ist 4 CLIP LEDS Schaltet sich ein wenn die maximale Lautstärke erreicht ist und bevor das Signal zu verzerren beginnt Sie zeigen an dass der eingebaute Begrenzer seine Arbeit aufnimmt Von Zeit zu Zeit kann es vorkommen dass die Clip Leds aufleuchten Wenn Sie über einen längeren Zeitraum aufleuchten drehen Sie die Lautstärke am Verstärker zurück 5 BETRIEBSMODUS LEDS Diese LEDs zeigen den ...

Страница 15: ... Verstärker benötigen um ein Stereosystem zu erhalten Es gibt 2 verschiedene Möglichkeiten die Verstärker anzuschließen Möglichkeit 1 ein Verstärker pro Seite für hohe und niedrige Outputs In dieser Installation benutzen wir Kanal 1 für die Mittelhochtonbox und Kanal 2 für den Tieftöner an beiden Verstärkern Wir benutzen einen Verstärker für den linken Kanal und einen Verstärker für den rechten Ka...

Страница 16: ...de las directrices nacionales y europeas actuales Se ha establecido la conformidad y las instrucciones y documentos correspondientes han sido depositados por el fabricante Amplificador profesional de 2 canales con filtro de cruce activo integrado Carcasa muy compacta sólo 88 mm de altura Suministro de energía que garantiza una potente reproducción de graves Filtros de cruce activos integrados sin ...

Страница 17: ...eguridad se prohibe realizar modificaciones no autorizadas en la unidad CAUTION PRECAUCIÓN Para reducir el riesgo de electrocución no quite la cubierta superior Ninguna pieza usable adentro para el utilizador Dirijase unicamente a personal cualificado El simbolo de un rayo en el interior de un triangulo alerta sobre la presencia o el uso de elementos no isolados donde un voltaje peligroso constitu...

Страница 18: ...brada Utilice cables de audio de buena calidad XLR cinch o JACK cinch Cableado del conector XLR PIN1 GND PIN2 pos PIN3 GND conectar a PIN1 Cableado del conector JACK Hilo GND PUNTA pos ANILLO GND conectar a hilo ESPAÑOL MANUAL DE FUNCIONAMIENTO JB SYSTEMS 32 41 D2 900 D2 1200 D2 1500 12 Salidas de enlace XLR en varios casos necesitará mucha potencia que no puede producirse con un sólo amplificador...

Страница 19: ...cador B en filtro de pase bajo Ajuste la frecuencia de cruce 17 para ambos canales del amplificador B Cierre los controles de ganancia 2 en ambos amplificadores Encienda ambos amplificadores 9 Abra los controles de ganancia 2 del amplificador A al nivel deseado Abra los controles de ganancia 2 del amplificador B hasta que haya un buen equilibrio entre los armarios superiores y los altavoces de gra...

Страница 20: ...ra A condensação poderá afectar o desempenho da unidade ou até danificá la Esta unidade destina se unicamente a utilização em espaços fechados Não introduza objectos de metal nem verta líquidos no interior do produto correrá risco de choque eléctrico ou poderá danificar o produto Caso algum objecto estranho entre em contacto com o interior da unidade desligue a de imediato da corrente Não coloque ...

Страница 21: ...vel máximo de som desejado seja alcançado Certifique se que ninguém consegue aceder aos controlos de ganho do amplificador Acabou de definir o nível máximo de som que o DJ poderá produzir Os seus vizinhos ficarão agradecidos em alguns casos o DJ nem por isso Nota Nos modo Bridge apenas o controlo de ganho do canal esquerdo é utilizado para ajustar a sensibilidadedeentrada 3 LEDS SIGNAL Estes LEDs ...

Страница 22: ...JB SYSTEMS 40 41 D2 900 D2 1200 D2 1500 Usado comos filtros de crossover para obter um sistema estéreo activo Por favor note que quando usado num sistema activo necessita de 2 amplificadores para obter um sistema estéreo Existem 2 opções diferentes para conectar os amplificadores Opção 1 Um amplificador por lado para saída de altos e baixos Neste sistema nós usamos o canal 1 para a coluna topo e o...

Страница 23: ...2x 500Wrms Potência estéreo 4Ω 1kHz THD N 0 1 2x 450Wrms 2x 600Wrms 2x 750Wrms Potência bridge 8Ω 1kHz THD N 0 1 900Wrms 1200Wrms 1500Wrms Resp Freq 0 5dB 20 20 000Hz Crossoveractivo Crossover incorporado 24dB oct 90 250Hz Sensibilidade de entrada 770mV Impedância de entrada 20kΩ Balanceado 10kΩ s balanceado Rácio S R 90dB Damping factor 8Ω 1kHz 600 Arrefecimento Ventoinha de 2 velocidades Conexõe...