2
9
Install the flue system (see flue installation instructions supplied with flue
system). Remember:
•
The flue system should rise vertically from the appliance with as few offsets
as possible. Offsets should be avoided where possible as each change in
direction creates a resistance to airflow.
•
The flue system must be well sealed with a minimum of 3 fixings at each
joint.
•
The flue pipe penetrating the chimney must continue to the minimum length
of 4.6m from the top of the floor protector to the cowl.
•
Flue exiting more than 3 metres from the ridgeline must not terminate less
than 1 metre above the roof penetration (see diagram 1 below).
•
Where the top of the flue pipe is more than 2 metres above its highest fixing
point, it must be stayed against high winds.
10
Drill and fix flue system into flue spigot with stainless steel self-tapping screws.
11
Drill and secure the appliance to the floor protector using the two rear holes
behind the pedestal.
12
Fit steel top baffle plate into position by resting plate on rear side pins. Line up
notches in baffle with forward side pins. Lift baffle above side pins and slide
baffle to the back of the heater. Correct final position has the baffle rear hard
against the back of firebox and the baffle’s folded front edge turned downwards.
(See diagram 2).
1-05-06