77
Section 5: Slideout Systems
Emergency Retract Mode:
Use this procedure when there is
NO
loss of power or electrical problem with the system.
1.
Remove the touchpad (Fig 4) from the wall.
2.
Prior to clearing the MAJOR fault, record the number of
RED & GREEN flashes observed on the touchpad (Fig 6).
This information will help your dealer/service center in
troubleshooting the slideout system.
3.
Press and hold the SET STOPS/CLEAR FAULTS button on
the back of the touchpad for five (5) seconds (Fig 2). Both RED & GREEN LEDs will
be on solid while pressing this button. After 5 seconds, the GREEN LED will begin
flashing and the RED LED will remain solid on.
4.
The unit is now ready to retract the room. Press and hold the ROOM SLIDEOUT
MOTOR buttons 1 and 2 on the back of the touchpad (Fig 3).
Press the IN button on the front of the wall touchpad until the room is fully retracted. If one
side of the room needs to retract further in order to get a good seal, press and hold the motor
button (Fig 3) corresponding to
ONLY
the motor you want to move. Press the IN button on
the front of the touchpad to retract the room the remainder of the way.
5.
Re-install the wall touchpad.
6.
Take the unit to an OEM certified dealer for repairs.
Manually Retract Room with Ratchet & Socket:
If the power is lost to the slideout motor(s) or the override mode above will not work, the
room may be manually retracted using a ratchet and socket attached to the end of the coupler
(Fig 11).
1.
Gain access to the VERTICAL CHANNEL assembly from inside or outside of the
coach (whichever is more convenient). Remove the trim and flange pieces on the
slideout room box.
2.
If applicable, remove the top screw from the bulb seal at the top of the VERTICAL
CHANNEL (Fig 8).
3.
Pull down the bulb seal and remove the motor cover (Fig 9). The motor seal may stick
to the bulb seal.
4.
Using a pick tool, remove the end of the retaining spring from the motor spring clip
(Fig 10A). If not equipped with a retaining spring, loosen the motor retaining screw
(Fig 10B).
It is very important to note that during this procedure, the slideout control
has NO stop locations. Use a second person to assist in determining when
the room is retracted. Damage to the room can occur if the room is
retracted too far.
NOTE:
After overriding the system, the room control will
need to be re-programmed by an OEM authorized dealer.
Table of Contents
Maintenance Record
Содержание Precept 2018
Страница 1: ...2016 CAMPING TRAILERS 2018 Class A Motorhome Owner sManual PRINTED ON RECYCLED PAPER 0230295 2018 ...
Страница 2: ......
Страница 4: ......
Страница 10: ......
Страница 12: ...10 Table of Contents Maintenance Record ...
Страница 38: ...36 Section 2 Occupant Safety Notes Table of Contents Maintenance Record ...
Страница 44: ...42 Section 3 Pre travel information Notes Table of Contents Maintenance Record ...
Страница 164: ...162 Section 14 Travel Camping Storage Checklists Notes Table of Contents Maintenance Record ...
Страница 168: ...166 Section 15 Additional Information Notes Table of Contents Maintenance Record ...