59
Section 5: Slideout Systems
Power Gear Slim Rack Slideout System
The Power Gear® Slim Rack slideout is typically used
for slideouts 144” long and longer.
It is operated by a 12VDC electric motor.
The system is equipped with a manual over-
ride allowing the room to be extended / retract-
ed in the event of a power loss.
The system has a controller (Fig 1) with pro-
grammable stops that stop the motor when the
room is fully extended or retracted.
The controller has the ability to detect faults
for easier troubleshooting.
A wall mounted touchpad allows room movement and provides end user feedback.
Operating the Slideout
The slideout will not function until the stops are properly
set or faults are cleared.
A solid “ON” GREEN LED
indicates room movement.
The RED LED indicates a fault or a problem
with the
system. (Refer to the
Fault Diagnostics / Troubleshoot-
ing
).
Prior to moving the slideout room set the parking
brake.
To ensure ample voltage is being supplied to the slideout
system motor, power should be supplied from one of the following sources:
Attach the RV to shore power.
Have the motor home engine running.
Turn on the generator.
Extending/retracting the room
1.
Engine or generator must be running, or plugged into shore power.
2.
Transmission must be in park or neutral (if applicable).
3.
Set the parking brake and level the unit.
4.
Remove transit bars (if so equipped) if extending the room; install if retracting.
5.
Turn
ON
the on/off switch or key.
6.
Press and hold the OUT button. To retract, press and hold the IN button. There will be
a slight delay before the room begins moving.
7.
The GREEN LED should be solid ON when room is in motion.
8.
Release the OUT button when the room is fully extended or the IN button when fully
retracted, and stops moving.
9.
Turn
OFF
the on/off switch or key.
Fault Diagnostics / Troubleshooting
The control has the ability to detect and display several faults. When a fault is detected,
room movement stops and two different LEDs will flash in a pattern.
The RED FAULT CODE LED will flash a number of times corresponding to a specific fault
code (refer to the Fault Code Chart).
The GREEN ROOM MOVEMENT LED will flash GREEN a number of times correspond
-
ing to which motor has the associated fault.
Example: (4) RED flashes and (2) GREEN flashes indicate a motor fault on motor 2.
Table of Contents
Содержание JAY FLIGHT 2023
Страница 2: ......
Страница 6: ...F Table of Contents...
Страница 8: ...2 Section 1 Warranty Service Table of Contents...
Страница 22: ...16 Section 1 Warranty Service Notes Table of Contents...
Страница 98: ...92 Section 7 Fuel Propane System Notes Table of Contents...
Страница 120: ...114 Section 8 Plumbing System Notes Table of Contents...
Страница 132: ...126 Section 10 Appliances Table of Contents...
Страница 134: ...128 Section 11 Electronics Notes Table of Contents...
Страница 148: ...142 Section 13 Exterior Travel Trailers Sealant Diagram Table of Contents...
Страница 152: ...146 Section 14 Travel Camping Storage Checklists Notes Table of Contents...
Страница 157: ...151 Section 15 Additional Information Notes Table of Contents...