Section 8: Plumbing System
the hose in a container holding the sanitized solution. To assist the syphoning process
set the container on a flat surface approximately (2) feet above ground level.
3.
Place the utility center valves in the SANITIZE TANK position.
4.
Turn the water pump ON.
5.
Solution will be drawn into the fresh water tank. When all the solution is in the tank, set
the utility center water valves to the city fill tank position.
6.
Remove the container and the short hose from the fresh water connection inlet.
7.
Attach a hose (can be your drinking water hose) to the fresh water connection inlet and
attach the other end of the hose to a potable pressurized water source.
8.
Turn on the pressurized water source and finish filling the fresh water tank.
9.
When the tank is full, turn off the water source, disconnect the hose from the water
source, and remove it from the fresh water connection inlet (at the utility center or on
the outside of the motor home).
10. Set the utility center valves to the NORMAL position.
11. Turn the water pump ON.
12.
Open all hot water faucets one by one until water begins to flow continuously and a
chlorine smell is noticeable. Include outside shower faucets (if so equipped).
13. Close the hot water faucets and repeat opening all cold water faucets one by one until
you smell chlorine. Include outside shower faucets (if so equipped) and toilet.
14. Let the solution remain in the system for at least four hours when disinfecting with 50
PPM residual chlorine. If a shorter time period is desired, then a 100 PPM chlorine
concentration should be permitted to sit in the system for at least one hour.
15. After the required period, drain the chlorine solution from the fresh water system (see
Draining the Fresh Water System
). Since the water heater was bypassed there should
be no sanitizer in the (storage) tank water heater.
Rinse the system with fresh water:
16.
Re-fill the fresh water tank using clean (potable) water. Refer to
Country Fill or City
Fill in Utility Center
section to re-fill the tank. If city water is not available, the tank
can be siphon (country) filled.
17. Set the (storage) tank water heater bypass valves to normal: hot & cold supply lines
ON, middle (mixer) valve OFF.
18. Set utility center water valves to the normal position and turn the pump ON to circulate
fresh water through the lines.
19. Open hot & cold lines to all faucets and outside shower until chlorine smell is gone.
20. Restore power to the (storage) tank water heater only when it is full of water. Tank less
water heater: turn the power switch ON (water is heated on demand).
NOTE:
If a chlorine taste still lingers in the water, flush the water
system with a solution consisting of one-quart vinegar to five gallons
of clean water. Re-flush as necessary.
The vinegar solution may
damage the water heater or the water filter, so both must
be bypassed again before performing this operation
. To
add the vinegar solution, follow the same procedure used to add the
sanitizer to the system.
Table of Contents
Maintenance Record
Содержание Alante 2018
Страница 1: ...0188485 2018 2018 Class C Motorhome PRINTED ON RECYCLED PAPER Owner sManual...
Страница 2: ......
Страница 4: ......
Страница 10: ......
Страница 12: ...2 Table of Contents Maintenance Record...
Страница 38: ...28 Section 2 Occupant Safety Notes Table of Contents Maintenance Record...
Страница 44: ...34 Section 3 Pre travel information Notes Table of Contents Maintenance Record...
Страница 68: ...58 Section 4 Vehicle Operation Notes Table of Contents Maintenance Record...
Страница 102: ...92 Section 6 Electrical System Notes Table of Contents Maintenance Record...
Страница 154: ...144 Section 12 Interior Notes Table of Contents Maintenance Record...
Страница 164: ...154 Section 14 Additional Information Notes Table of Contents Maintenance Record...
Страница 168: ...158 Section 15 Additional Information Notes Table of Contents Maintenance Record...