background image

 

Figure 2.8 APRAGAZ sockets and guide arc on the camera 

 

6.

 

Install the transparent cover. Please aim the two gaps on the flange of transparent cover (shown in figure 2.9) 
at the hook lock on the cover (shown in figure 2.10). Finally, fasten the two fixing screws on the two sides. 

 

Figure2.9 The transparent lower dome casing 

 

 

 

Figure 2.10 Installation of lower dome casing 

 

2.3 Initial setting 

 Address: 

 Baud 

rate: 

2400 

 120

 matching resistance: OFF 

 
 
 
 

 

Содержание QC8602

Страница 1: ...Integrated Intelligent Speed Dome User Manual V 1 0 1...

Страница 2: ...ON 5 2 3 INITIAL SETTING 8 2 4 SWITCH SETTING 9 CHAPTER 3 OPERATION INSTRUCTION 12 3 1 POWER ON ACTION 12 3 2 BASIC FUNCTION GUIDE 12 3 3 PRESET POINTS FUNCTIONS 13 APPENDIX A LIGHTNING AND SURGING PR...

Страница 3: ...eral devices to one power adapter as adapter overload may cause over heat or fire hazard 4 Please make sure that the plug is firmly connected on the power socket 5 When the product is installed on wal...

Страница 4: ...hall be kept from rain and moisture 5 Exposing the equipment to direct sun light low ventilation or heat source such as heater or radiator is forbidden ignorance can cause fire danger 6 Please use the...

Страница 5: ...othly and quietly the images have no vibration 1 2 Build in Integrated Camera Auto focus Auto back light compensation Auto white balance tracking Auto day and night functionality depending on the came...

Страница 6: ...porates zooming effect Proportional Zooming Vertical and Horizontal scan speed will be changed during zoom time as speed down if zoom out and speed up if zoom in to get better monitoring performance I...

Страница 7: ...When remove the camera pull the hook locks at the two sides of the camera with two hands and drag out the camera at the same time Removing the camera expose the speed dome chassis shown in Figure 2 1...

Страница 8: ...SW2 on on Figure 2 4 Dial up switches on the profile of the camera 4 Install the dome cover Open the joint interface on the cover pull the wire twisted in the bracket into the dome cover through the...

Страница 9: ...n the camera shown in figure 2 8 to the APRAGAZ sockets on the dome chassis shown in figure 2 7 Plug the camera into the cover with the guide arc along with the guide pillar on the chassis until you w...

Страница 10: ...flange of transparent cover shown in figure 2 9 at the hook lock on the cover shown in figure 2 10 Finally fasten the two fixing screws on the two sides Figure2 9 The transparent lower dome casing Fig...

Страница 11: ...This speed dome Self adaptive Pelco P Pelco D and HIK Code protocols 2 4 1 Device address setting SW1 is used to set device address as follow Device address Dialing setting schematics 1 2 3 4 5 6 7 8...

Страница 12: ...OFF OFF OFF OFF ON OFF OFF 33 ON OFF OFF OFF OFF ON OFF OFF 34 OFF ON OFF OFF OFF ON OFF OFF 35 ON ON OFF OFF OFF ON OFF OFF 36 OFF OFF ON OFF OFF ON OFF OFF 37 ON OFF ON OFF OFF ON OFF OFF 38 OFF ON...

Страница 13: ...for specific baud rate is listed as below SW2 baud rate switch setting Baud rate Dialing setting schematics 1 2 3 2400 ON OFF OFF 4800 OFF ON OFF 9600 ON ON OFF 19200 OFF OFF ON 38400 ON OFF ON 2 4 3...

Страница 14: ...reaching contact point it will move up quickly and stop at 45o 3 2 Basic Function Guide The following operation shall be done in collaboration with backline control device or client software Control...

Страница 15: ...l preset and is reserved Refer to chapter 3 3 3 3 Preset points functions 3 3 1 Analog speed dome special preset function Analog integrated speed dome can only be operated by preset and all the operat...

Страница 16: ...Auto scan path 3 Close camera configuration Close parity and Verification 84 Clear all presets information 85 86 Auto scan path 4 87 88 89 Auto scan path 5 90 91 No 2 auto scan Start auto scan path h...

Страница 17: ...se Sensor Up for SONY camera 45 Auto focus Half auto focus 46 Open park action Auto park action 10s 47 Close park action Auto park action 30s 48 Preset 1 Auto park action 60s 49 Preset 2 Auto park act...

Страница 18: ...ith movement limitation the speed is adjustable If don t set the movement limitation it moves continuously It support park action as well and park action time is optional from 10s to 300s There are 6...

Страница 19: ...duction voltage areas such as high voltage transformer substation high power lightning protection apparatus and lightning conductor are necessary to be appended The design for installation and wiring...

Страница 20: ...s 800m When using thin communication wire or using the products in strong electromagnetic interference environment or many devices are connected on the bus the maximum length should become shorter acc...

Страница 21: ...e likely to use star connection in practice at this time match resistance should be connected at the two devices that most apart In figure four those are device one and device 15 But as this connectio...

Страница 22: ...matched between Host and the Speed Dome 1 Adjust the address or Baud Rate of Host or Speed Dome to make a match 2 RS485 are connected incorrectly 2 Change the RS485 and RS485 wires 3 Wiring drops 3 fa...

Страница 23: ...oltage wastage rate is below 10 the recommended maximum transmission length is as follows For the AC power supply device the biggest voltage wastage rate is 10 For example a device with 80VA rated pow...

Страница 24: ...Appendix D Wire Gauge Comparison List Home and Abroad 22...