10
www.javad.com
Note:
Do not make other changes without consulting the Net-
View Software Manual.
1. Connect the receiver and computer, start NetView
and establish the connection as described above.
2. Click
Receiver
4
Parameters
on the left panel.
3. In the
General
tab check antenna status and set
the parameter
Antenna Input
to
External
if the external
antenna will be used.
Figure 7.
General tab
4. Open the Log files tab and then TriPad tab and set
the following parameters, click
Apply
.
Note:
Parameter
Base
Rover
Implicit Message Output
Period
15 seconds
Elevation mask angle
15 degrees
File name prefix
Enter a unique ID, such as the last 3 digits
of receiver’s serial number. By deafault the
prefix is log
FN key mode
(starts/stops the data recording when FN
button is used)
Select LED blink
mode switch for
Static data
Select Occupation
mode switch (for
RTK)
Initial dynamic mode
-
Select Dynamic (for
trajectory survey)
Click Apply every time after the parameter was changed,
otherwise the receiver won’t save the changes. Click Refresh, to
ensure the changed parameters and new configuration are saved.
Figure 8.
Log Files tab
Figure 9.
TriPad tab
5. Open
Positioning
tab and set the Elevation mask
to 15 degrees .
Figure 10. Elevation mask
6. To set up the base station, open the
Base
tab and
set the following parameters:
Antenna Phase Center
Position (APC)
- enter latitude, longitude, and altitude
(ellipsoidal height) values of the antenna position. Do
Содержание DELTA-3
Страница 21: ...www javad com 21 ...