Maintenance procedures
Limiter thermostat
The device limiter thermostat may be trig-
gered during transport - water will not be
heated during this time.
Reset the limiter by loosening and removing
the cover screw with a hex key (2.5mm) or
Torx bit (T10).
Then, press the button inside the hole with
the hex key or other suitable rod.
When the limiter has been triggered, a slight
click will be heard. The limiter must not be
pressed very hard.
If the limiter is triggered during normal opera-
tion, it can be reset one time. If the limiter is
triggered a second time within a six-month pe-
riod, the thermostat is defective and must be
replaced immediately. For safety reasons, the
device must not be operated again.