14
The flue gas temperature is too low
•
Ensure that the primary and secondary air
ratio and volume are correct.
•
Ensure that the firewood is dry.
•
Shorten the turbulators if necessary by
removing the lower plate from each ele-
ment in order to increase the flue gas tem-
perature.
The extractor fan won't work
•
Ensure that the boiler water temperature is
below 90 ºC and that the thermostat indi-
cator lamp is on since the set value of the
extractor thermostat is 90 ºC.
•
Check the set value of the flue gas ther-
mostat.
•
Check that the temperature limiter has not
tripped. For acknowledgement, open the
protective cap and press the limiter. How-
ever, let the boiler temperature cool down
before acknowledgement. Find out why
the temperature limiter tripped.
•
If the extractor fan produces abnormal
sound when working the trouble can be
caused by a motor bearing or a blade.
•
If the extractor power has dropped then
the blades have to be cleaned.