Jason International, Inc. •
501.771.4477
Page 5 of 8
Customer Service : 800.255.5766
OPeraTInG InsTruCTIOns, FeaTures, anD COnTrOls
InTrODuCTIOn
This manual contains all of the information needed for the
proper operation of this Jason Integrity
TM
AirMasseur
®
bath.
The bath has been designed to provide years of relaxing
trouble-free service, provided the unit is maintained and
operated in accordance with these instructions.
WaRNINg: bEfORE OPERatINg, REfER tO thE INStRuCtIONS
PERtaININg tO thE RISK Of fIRE, ElECtRIC ShOCK, OR INJuRY
tO PERSONS ON thE laSt PagE Of thIS maNual.
Thoroughly clean and disinfect the unit as described
in the
ClEaNINg
section of the
uSER maINtENaNCE
INStRuCtIONS
on page 6 before its first use and periodically
thereafter.
All Jason Integrity
TM
AirMasseur
®
baths are pre-plumbed at
the factory with standard equipment. Standard equipment
includes a quiet 1 HP, variable-speed blower with integral
heater; 20-minute timer ; and Air switch controls with “On/
Off” and blower speed functions.
FIllInG anD DraInInG
Close the drain and fill the bath with water to at least 10”
below the bath deck. The maximum recommended bathing
temperature is 104°F (40°C).
Before starting the blower, ensure that it is plugged into the
air switch control box and that the control box is plugged into
its dedicated electrical service connection.
Turn the blower Off before draining the water. The bath unit
and its plumbing are designed to drain after each use, whether
used as an AirMasseur
®
or a soaking bath..
BlOwer
The Jason Integrity
TM
AirMasseur
®
system contains a variable
speed-controlled heated air blower. The blower provided is
factory tested when assembled onto the bath. The blower
must be plugged into the air switch control box, which must
be plugged into its dedicated GFCI electrical service prior
to turning it on.
aIr On/OFF BuTTOn
The Air On/Off button (air switch activator)
allows the user to turn the blower On and Off
and controls the blowers intensity. Momentarily
depress the Air On/Off button to start or to stop
the air blower. A timer will automatically stop
the air blower after 20 minutes of operation if
it is not stopped manually.
NOtE:
If the unit fails to operate, check the breaker panel
to insure that the circuit breaker is On. Check the GFCI by
testing and resetting it. If the unit still fails to operate, refer to
the
trouble Shooting guide
section of this manual on page 6.
blOWER SPEED
Once the blower is On, to decrease the air output, press and
hold the Air On/Off button until the desired intensity is reached,
then release the Air On/Off button. To increase the air intensity,
press and hold the Air On/Off button until the desired intensity
is reached, then release the Air On/Off button.
COnTrOl BOX
The blowers Air On/Off button control box is built to plug into
the dedicated GFCI electrical circuit. A 36” powercord with
a plug end is prewired to the blower, which must be plugged
into the control box. A built-in timer shuts the blower off
20-minutes after being activated.
auTOMaTIC PurGe CYCle
Fifteen minutes after the blower is stopped and the bath is
drained, the blower will automatically start for two (2) minutes
to purge and dry the air channel system.