InsTallaTIOn

See the uSER maINtENaNCE INStRuCtIONS on page 5 for humidity 

and mold prevention suggestions prior to Installation. 

1. 

finish frame

  Construct a finish frame under the bath rim to keep the 

bath deck level and insure proper drainage toward the 

bath well. This frame is not intended to support the full 

bath weight. 

(See figure 1 & figure 2.)

 

 

NOtE: 

If you use a tile flange kit, modify the framing to 

support  the bath lip as shown in 

figure 1

.

  Jason offers a removable lateral skirt for most baths.  The 

skirts are available in matching acrylic colors and provide 

convenient access to the bath equipment as well as an 

excellent finished appearance.  

 

If a lateral skirt is to be used, the bath deck muSt be leveled at 

20.5” from the support flooring, or the skirt will not fit properly.

  If a Jason lateral skirt is not used, an access panel MUST 

be  provided  to  enable  final  electrical  connections  and 

service.  Refer to Table 1 - Specifications for the minimum 

recommended access panel size.

 

CautION:  

Make sure the support frame is drilled and/or notched 

as needed to assure that the air actuator and air tube are not 

bound or pinched.

  Apply  100%  Silicone  with  water  resistant  properties 

between  the  the  water-resistant  backer  board  and  the 

deck of the bath.

2. 

Rough-in the plumbing for the drain and overflow assembly.  

At this 

time also plan for the  position and mounting of the faucet 

set, as well as all related plumbing. All overflow drains, 

fill spouts, and valves must be installed according to the 

instructions in this manual. If a Jason Double Cascade

TM

 

is provided, refer to the included instructions and install 

at this time.

3. 

level the bath and remove packing board:

a. 

Install the bath level for proper drainage. 

 Jason baths are 

designed to be supported under the entire base of the 

bath. If the floor is smooth and level, the bath’s Level-

Form™ base will provide proper drainage and support. 

 

(See figure 3.)

 Mortar is required when the subfloor is 

not smooth and level; when additional sound insulation 

is desired; or when the bath is installed in a drop-in 

application. In alcove installations, a bed of mortar may 

also be recommended to aid in leveling the bath.  

NOtE:  

Do not use sand to install or level the bath.

b. 

Remove the packaing board before installing the bath.  

The 

AirMasseur

®

 is equipped with separate bath and blower 

support bases which are joined for shipment with a 

packing  board. 

Detach the packing board from the bath 

and from underneath the blower.

4. 

Protect the acrylic bath surface from damage during installation 

with a suitable material,

 i.e. cardboard and/or plastic film.  

5. 

Install the drain and overflow assembly

 onto the bath according 

to the instructions provided with the assemblies.  Position 

the bath in the general area of intended installation.  

InsTallaTIOn InsTruCTIOns

tablE 1 - SPECIfICatIONS

model

Overall

Dimension

l x W x h (in.)

Operating

Capacity

gal

blower

120V

hP

min. Size

access

W x h (in.)

floor

loading

lbs/ft

2

B3060

60 x 30 x 20.5

29

1

36 x 17

49.7 lbs

B3260

60 x 32 x 20.5

32

1

36 x 17

49.1 lbs

B3660

60 x 36 x 20.5

37

1

36 x 17

47.2 lbs

B3666

66 x 36 x 20.5

39

1

36 x 17

44.4 lbs

B3672

72 x 36 x 20.5

45

1

36 x 17

44.8 lbs

B4260

60 x 42 x 20.5

44

1

36 x 17

47.2 lbs

B4272

72 x 42 x 20.5

49

1

36 x 17

42.6 lbs

C6060

60 x 60 x 20.5

54

1

36 x 17

42.1 lbs

D3260

60 x 32 x 20.5

36

1

36 x 17

52.1 lbs

N4260

60 x 42 x 20.5

49

1

36 x 17

48.2 lbs

N4272

72 x 42 x 20.5

52

1

36 x 17

46.3 lbs

V4272

72 x 42 x 20.5

46

1

36 x 17

42.3 lbs

W4266

66 x 42 x 20.5

40

1

36 x 17

42.6 lbs

Содержание Integrity AirMasseur B3260

Страница 1: ... in transit is the responsibility of the carrier The owner or installer MUST open uncrate and inspect the unit for damage when it is delivered Inspect plumbing and whirlpool surface for missing or damaged components Alertthedealerofanydiscrepancies Ifdamage is discovered immediately notify the carrier in writing and request that they have a representative inspect the unit If the carrier fails to r...

Страница 2: ...d install at this time 3 Level the bath and remove packing board a Install the bath level for proper drainage Jason baths are designed to be supported under the entire base of the bath If the floor is smooth and level the bath s Level Form base will provide proper drainage and support See Figure 3 Mortar is required when the subfloor is notsmoothandlevel whenadditionalsoundinsulation is desired or...

Страница 3: ...ng any work Use 1 5 ABS or PVC plastic tubing Locatethecontrolboxwiththeblowerinanareaaccessible for servicing NOTE A 15 foot replacement air switch tube can be purchased from a Jason dealer if needed To insure proper functioning of the system avoid remote mounting in a location which requires more than six 6 piping direction changes A 90 direction change should be made up of two 45 elbows for max...

Страница 4: ...ircuitInterrupter GFCI protected 120v volt 20A amp 60Hz hertz circuit with a service ground DANGER RISK OF ELECTRIC SHOCK Connect only to a circuit protected by a Ground Fault Circuit Interrupter GFCI In the unlikely occurrence of a current imbalance in the power conductors the GFCI will interrupt the power to the bath INSTALLSERVICECONNECTIONATLEAST6 ABOVE THE SUB FLOOR The air switch control box...

Страница 5: ...or a soaking bath Blower TheJasonIntegrityTM AirMasseur systemcontainsavariable speed controlled heated air blower The blower provided is factory tested when assembled onto the bath The blower must be plugged into the air switch control box which must be plugged into its dedicated GFCI electrical service prior to turning it on Air ON OFF BUTTON The Air On Off button air switch activator allows the...

Страница 6: ...r is activated Even through all Jason IntegrityTM AirMasseur baths provide preheated air occasionally some people with sensitive skin mightexperienceacoldairsensation Thissensationiscaused by the swiftly moving heated air bubbles blowing on the wet skin This phenomenon can be related to the use of a fan for cooling on a hot day While the ambient temperature does not change the moving air makes you...

Страница 7: ...turer or supplier To obtain warranty service you must contact the retailer from which the merchandise was purchased or Company s distributor in your area Written notice of warranty defects must be given to the company within thirty 30 days from the occurrence thereof Written permission must be obtained by the retailer or distributor from the Company before any equipment claimed defective is return...

Страница 8: ...bathwhileundertheinfluenceofalcohol anticoagulants stimulants antihistamines vasoconstrictors vasodilators hypnotics narcotics or tranquilizers F Persons with a medical history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a physician before using an AirMasseur bath G Persons using medication should consult a physician before using an AirMasseur...

Отзывы: