PAGE
T.22
DATE
07/09
Supercedes 06/08
while the key is pressed. The time remaining on the
purge cycle is displayed after the bath has drained.
“Purge Stop” is displayed while the key is pressed
during the purge cycle. This action will terminate the
purge cycle. The mode settings will be remembered
on the next startup.
BLOWER SPEEDS (+- ICON)
Hold the key in Constant mode to go from High to Low
then release and hold again to go from Low to High.
Hold the key in Wave and Pulse mode to go from
High to Medium and Medium to High. The system
remembers the last speed setting on the next startup.
The icon will light up when the blower is running.
The LED displays blower speeds from “10” (Low)
or “55”(Med) to “99” (High) while the key is pressed.
You can reduce the auto purge idle time from 20 to
10 minutes, by pressing and holding the key for more
than 5-seconds during the purge idle period.
CUSTOMIZED SETTINGS
The 12 character LCD display can be customized
by pressing the Blower and Blower Speeds icons
simultaneously for five (5) seconds, while the system
is Off.
Note:
The Blower Speeds icon will not be
illuminated during this process. Use the figure to
locate the icons. A menu will be displayed to choose
the following: Purge 24, (starts the blower every 24
hours for two (2) minutes at the same time the purge
was set), Product Test Diagnostics, Temperature (F
or C), and Language (English or Spanish).
MENU INSTRUCTIONS
Use the Blower icon to scroll through the different
menu items. Use the Blower Speeds icon to change
an option. For example, press and release the Blower
icon to change from Purge 24 to Product Test, press
and release again to arrive at the Temperature option.
Press and release the Blower Speeds icon to change
the temperature display from F (Fahrenheit) to C
(Celsius).
PRODUCT TEST DIAGNOSTICS
After selecting the Product Test option from the menu,
the unit will perform a series of tests to confirm correct
installation of components. The test will begin by
displaying the configuration number, followed by the
software revision number. Next, the ISD-237 control
box will be tested to ensure proper IR communication.
The display will then test the Temperature and Low
Water level sensor (ITW-209). Next, each of the six (6)
icon buttons will begin to light. Press the illuminated
button to proceed to the next icon. After the icon
test, the pump will start for two (2) seconds on the
high setting. Lastly, the LED light unit will be tested.
If you receive and error on any of the tests, confirm
proper installation of the component to the correct
control box.
REMOTE CONTROL
Home Spa bath control system includes a waterproof
floating universal remote. It controls all bath functions
plus TV, DVD, CD, etc. which can be heard through
the Sound Immersion Transducers (4-each).
PAGE
T.22
DATE
11/07
Supercedes 07/07