JASON Hydrotherapy forma AC630 Скачать руководство пользователя страница 11

Jason International, Inc.  •  

 

501.771.4477  

 

 

 

Page 11 of 12

 

 

 

 

Customer Service :  800.255.5766 

TROUBLE SHOOTING GUIDE

ALL WArrAnTY rEpAIrS MUST BE AUTHOrIZEd BY JASOn BEFOrE WOrK IS STArTEd.

If you believe the unit to be within the warranty period, you must contact Jason

 

Customer Service at 1-800-255-5766 

with the bath’s Product and Serial numbers before work is started.
FOr SErVICE, ALWAYS COnTACT YOUr dEALEr Or AUTHOrIZEd SErVICE CEnTEr. 

WARNING: Always turn off power at the main electrical service panel when servicing the Air-Whirlpool bath

Blower

 

system of air-whirlpool Bath

sYMPTOMs

POssIBle Causes

reCOMMeNDeD aCTION

Blower system won’t operate.

a)  No power to air bath unit.

b)  Blower Motor is not plugged in.

c)  Keypad disconnected.

a)  Reset circuit breakers and check GFCI.  Check fuses and 

replace if bad.

b)  Make sure plug is fully inserted into the outlet.

c)  Check and reconnect if necessary.

Blower shut off by itself or before 

time elapses.

a)  Blower motor overheated and thermal 

protection device deactivated motor 

(possibly low voltage).

b)  GFCI tripped.

a)  Check that blower has suffcient ventillation and that the in-

take into the blower is not blocked.  Clear and allow motor 

to cool down. (Check service & wire size.)

b)  Refer to installer/dealer.

Circuit breaker trips repeatedly.

a)  Defective breaker.

b)  Short circuit between bath and blower 

breaker box.

c)  Other items are connected to the same 

circuit.

a)  Replace breaker.

b)  Refer to installer/dealer.

c)  Refer to installer/dealer.

Blower does not shut off.

a)  Defective keypad or timer.

a)  Refer to installer/dealer.  Replace keypad or control.

Air bath does not function prop-

erly while in the pulse or wave 

mode (Signature Edition).

a)  Blower speed setting is set too low.

a)  Change to a mid-range air speed setting before switching 

over to wave or pulse modes.

Standard Edition Purge cycle 

won’t operate.

a)  Purge cycle was disabled.

a)  Remove power to the bath, either by the circuit breaker or 

by unplugging and replugging the blower from the supply 

outlet.

Pump

 

system of air-whirlpool Bath

sYMPTOMs

POssIBle Causes

reCOMMeNDeD aCTION

Pump system won’t start.

a)  No power to the pump unit.

b)  Pump motor is not plugged in.

c)  Insufficient water.  

a)  Reset circuit breakers and check GFCI.  Check fuses and 

replace if bad.

b)  Make sure plug is fully inserted into the ourlet.

c)  Check and reconnect if necessary.

Pump operates, but no air is 

injected into water.

a)  Air valves are closed.

b)  Airl line is clogged.

a)  Open air control valves.

b)  Refer to installer/dealer.

Pump operates, but water is not 

being pumped.

a)  Suction or discharge blocked.

b)  Suction air leak.  (System usually 

surges.)

a)  Remove obstruction.

b)  Make sure union is tight on suction side of the purmp.

Pump does not manually shutoff.

a)  Defective keypad or control

a)  Refer to installer/dealer.  Replace keypad or control.

Pump unions leak.

a)  Unions cracked, under-tightened, 

over-tightened, or O-ring is not seated 

properly (possibly pinched).

a)  Refer to installer/dealer.  Replace keypad or control.

Pump shuts off by itself before 

set time elapses.

a)  Pump motor overheated and thermal 

protection device deactivated motor. 

(Possibly low voltage.)

b)  GFCI tripped.c) Water fell below recom-

mended level.

a)  Make sure motor air cooling vents are not  blocked.  Clear 

and allow motor to cool down. (Check service & wire size.)

b)  Refer to installer /dealer.

c)  Fill to recommended level (2” above jets).

Pump does not turn off after set 

time elapses.

a)  Wiring error or control problem.

a)  Refer to installer/dealer.  

Pump will not turn off when water 

is drained from bath.

a)  Water level sensor wires or ribon cables 

are shorted.

a)  Inspect all sensor wires or ribbon cables for exposed or 

touching wires.  Check for objects touching the back of the 

Signature low water level sensor unit. If problem continues, 

replace water level sensor unit.

LED light will not operate.

a)  Light bulb is loose in socket.

a)  Access bulb and assure it is properly installed in socket.

Содержание forma AC630

Страница 1: ... by warranty and is the responsibility of the installer ALL WARRANTY CLAIMS ON ACRYLIC SURFACE DAMAGE MUST BE MADE PRIOR TO INSTALLATION Inspect Owner s Manual forma Air Whirlpool Baths INSTALLATION OPERATION AND MAINTENANCE 49 1000 016 Date 04 08 Table 1 Specifications Jason International Inc 8328 MacArthur Drive North Little Rock AR 72118 www jasoninternational com OWNER S RECORD Dealer Date Pur...

Страница 2: ...blower and pump mount s to rest firmly on the floor The bottom of the blower and pump mount s must be secured and level with the bottom of the bath We recommend securing the blower and pump mounts to the floor with removable fasteners for ease of servicing WARNING Any modification to the equipment is not recommended and will void the Manufacturer s warranty 3 Jason baths are designed to be support...

Страница 3: ...ions are hand tight Do not over tighten or use a pipe wrench This will damage the unions and cause leaking If the unit leaks with the unions hand tight then loosen the unions s and check the O ring seal to ensure it is properly seated 9 The acrylic surface of this bath has been provided with a protectivefilmwhichhelpsprotectthebathduringshipment and installation Additional protection may also be r...

Страница 4: ...er GFCI In the unlikely occurrence of a current imbalance in the power conductors the GFCI will interrupt the power to the bath GROUNDING IS REQUIRED Theunitshouldbeinstalledbyaqualifiedservicerepresentative and properly grounded WARNING The electrical service to the GFCI must not be interrupted by any control device Likewise the electrical service from the GFCI to the bath control should be direc...

Страница 5: ...the same time everyday See Operating the Signature Edition Air Whirlpool Touchpad on pages 8 9 REMOTE CONTROL FEATURES In addition to the main control touchpad installed on the bath deck a floating waterproof Universal Remote Control is providedwithallSignatureEditionAir Whirlpools Thisremote controlprovidesthesamecontrolfunctionsasthebath smain control console plus the bather may remotely operate...

Страница 6: ...l box must be plugged into a 120v 15 amp GFCI dedicated circuit H Pre wired power cord to the blower I Air whirlpool control box connections SIGNATURE EDITION AIR WHIRLPOOL PARTS LIST Pump Pump Control Box Blower Blower Control Box Heater Keypad Keypad Cable Control Box Stand LED Light Assembly Ozone Sanitation Unit Water Level Sensor Jason s Signature Edition Air Whirlpool system is the most adva...

Страница 7: ... jets Blowers provided on Jason Air Whirlpool baths are factory tested when assembled and again retested after installation on the Air Whirlpool bath STANDARD EDITION AUTOMATIC PURGE Fifteen minutes after the control has shut off and the bath is completely drained the blower will start again for a two minute purge cycle that dries the air channel Note that the blower light will flash during the 15...

Страница 8: ...umandMedium to High The system remembers the last speed setting on the next startup The Blower Speeds icon will light up when the blower is running The LED displays the blower speed from 10 Low or 55 Med to 99 High while the key is pressed You can reduce the auto purge idle time from 20 minutes to 10 minutes by pressing and holding the key for more than 5 seconds during the purge idle period LED L...

Страница 9: ...n again to increase the blower speed until the desired intensity is reached The blower will return to its highest speed on any mode change Option The Option icon is used to operate an optional LED light if installed Press the icon for less than two 2 seconds to turn the lights Off or On Hold the icon for more than two 2 seconds to change modes This function has a two 2 hour timer and remembers the...

Страница 10: ... commercially available plastic polish i e Novus Plastic Polish No 2 available at your Jason dealer followed by an application of acrylic paste wax Buff the surface with a clean soft cloth Do not use sandpaper steel wool or abrasive rubbing compounds Ifscratchesaretoodeeptorubout orifthedamagepenetrates the acrylic surface consult your dealer for recommendations on surface repair AIR HEATER AND AI...

Страница 11: ...cle was disabled a Remove power to the bath either by the circuit breaker or by unplugging and replugging the blower from the supply outlet PumpSystem of Air Whirlpool Bath Symptoms Possible Causes Recommended Action Pump system won t start a No power to the pump unit b Pump motor is not plugged in c Insufficient water a Reset circuit breakers and check GFCI Check fuses and replace if bad b Make s...

Страница 12: ...ators hypnotics narcotics or tranquilizers F Persons with a medical history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a physician before using an Air Whirlpool G Persons using medication should consult a physician before using an Air Whirlpool bath since some medication may induce drowsiness while other medication may affect heart rate blood...

Отзывы: