Jason International, Inc.  •  

 

501.771.4477  

 

 

 

Page 4 of 12

 

 

 

 

Customer Service :  800.255.5766 

INSTALLATION INSTRUCTIONS (cont.)

ELECTRICAL

NOTe: 

 Verify the electrical service to match either the 120v 

or 240v systems. 

NOTe:

 The bath is designed for indoor use only. The electrical 

equipment must not be exposed to direct or indirect water 

or moisture contact. The electrical equipment must also be 

protected from dust and other airborne debris before, during, 

and after installation.

Standard Edition Air-Whirlpool

The blower and pump are prewired to their control boxes. The 

control boxes have a 36” cord with plug end. The blower and 

pump control boxes are mounted on a stand that is temporarily 

secured to the packing board for shipping. These boxes must 

remain on the control box bracket so that the two boxes can 

communicate properly through their infrared communication 

feature. During installation, the control box bracket and controls 

must be positioned horizontally and located to permit access 

for inspection and servicing. The blower control box must be 

plugged into a dedicated 120v (volt), 15A (amp), 60Hz (hertz), 

Ground Fault Circuit Interrupter (GFCI) protected circuit and 

the  pump  control  must  be  plugged  into  another  dedicated 

120v, 20A, 60Hz, gFCI protected circuit. 

If an optional 1kw (kilowatt) heater is operated with this control, 

then the pump control and heater must be wired into a dedicated 

30A (amp) service.  Note: The pump and blower dedicated 

circuits must only power their specified controls.

Signature Edition Air-Whirlpool

The  blower  and  pump  are  prewired  to  individual  control 

boxes. The control boxes have a 36” cord with a junction box 

connection. The blower and pump control boxes are mounted 

on a stand that is temporarily secured to the packing board for 

shipping. These boxes must remain on the control box bracket 

so that the two boxes can communicate properly through their 

infrared communication feature. During installation, the control 

box  bracket  and  controls  must  be  positioned  horizontally 

and  located  to  permit  access  for  inspection  and  servicing. 

The blower and pump junction box must be connected into 

a dedicated 240v, 20A, 60Hz, gFCI protected circuit. note: 

The pump and blower dedicated circuits must only power their 

specified controls.

INSTALL  SERVICE  CONNECTION  AT  LEAST  6”  ABOVE  SUB 

FLOOR.

A licensed electrician must provide the “dedicated” electrical 

service protected by a GFCI. The location of the GFCI must be 

at least five (5) feet away from the inside surface of the bath, 

accessible for regular testing. Use copper conductors only.

DANGER  —  RISK  OF  ELECTRIC  SHOCK

:  Connect  only  to  a 

circuit protected by a Ground Fault Circuit Interrupter (GFCI). 

In the unlikely occurrence of a current imbalance in the power 

conductors, the GFCI will interrupt the power to the bath.

GROUNDING IS REQUIRED.

The unit should be installed by a qualified service representative 

and properly grounded.

WARNING

: The electrical service to the GFCI must not be 

interrupted  by  any  control  device.  Likewise,  the  electrical 

service from the GFCI to the bath control should be direct and 

not interrupted by a switch. Never use a switch in conjunction 

with a control device. This will 

VOID THE MANUFACTURER’S 

WARRANTY.

DANGER

Do not alter the factory installed wiring.

  All  building 

materials and wiring should be routed away from the blower 

body or other heat-producing components of the unit.

all lOCal aND sTaTe eleCTrICal aND PluMBINg CODes MusT 

BE OBSERVED.

 Where there are no local codes the 

National 

Electric Code (NEC) 

and 

Uniform Plumbing Code (UPC)

 shall be 

observed.  It  is  the  responsibility  of  the  installer/owner  to 

determine specific code compliance prior to installation of 

the product. 

NOTe:

 In the Commonwealth of Massachusetts, 

installation  is  to  be  done  by  a  Massachusetts  licensed 

plumber.

REMOTE MOUNTING OF AIR BLOWER

The Jason Air-Whirlpool system has been factory installed 

following  E.T.L.  Guidelines.  During  installation,  if  remote 

mounting of the blower is desired or required, the following 

procedures should be followed. 

NOTe:

 Do not remote mount the blower more than 15 feet away 

from the air inlet of the bath. Choose a location as close as 

possible to the bath to assure maximum efficiency.

1.  The  installer  must  determine  the  layout  of  the  piping; 

exact remote mount location; and service access before 

beginning any work. Use 1.5” ABS or PVC plastic tubing. 

Locate  the  blower  in  an  area  accessible  for  servicing. 

NOTe:

 A 15 foot extension replacement cable set can be 

purchased from your Jason supplier, if needed. To insure 

proper functioning of the system, avoid remote mounting in 

a location which requires more than six (6) piping direction 

changes. A 90° direction change should be made up of 

two 45° elbows for maximum efficiency.

2.  If the blower has been factory installed, disconnect the 

blower from the air bath plumbing by removing the two 

(2) screws on the check valve outlet and disconnect the 

short piece of flex pipe between the check valve and the 

elbow by removing the two (2) screws in the elbow.  (Omit 

this step on baths where the blower is not factory installed 

and remote mounting is required.)

3.  Install  the  blower  in  the  remote  location.  The  remote 

mount locations’ ambient air temperature should remain 

at  approximately  22°C  (72°F)  for  optimum  air  heating. 

Make sure the blower is well ventilated. The blower mount 

should be attached firmly to the floor. piping between the 

remote blower location and the bath can be insulated using 

a minimum of 1/2” thick insulation. Attach new piping to 

the elbow of the existing piping.

Содержание forma AC630

Страница 1: ... by warranty and is the responsibility of the installer ALL WARRANTY CLAIMS ON ACRYLIC SURFACE DAMAGE MUST BE MADE PRIOR TO INSTALLATION Inspect Owner s Manual forma Air Whirlpool Baths INSTALLATION OPERATION AND MAINTENANCE 49 1000 016 Date 04 08 Table 1 Specifications Jason International Inc 8328 MacArthur Drive North Little Rock AR 72118 www jasoninternational com OWNER S RECORD Dealer Date Pur...

Страница 2: ...blower and pump mount s to rest firmly on the floor The bottom of the blower and pump mount s must be secured and level with the bottom of the bath We recommend securing the blower and pump mounts to the floor with removable fasteners for ease of servicing WARNING Any modification to the equipment is not recommended and will void the Manufacturer s warranty 3 Jason baths are designed to be support...

Страница 3: ...ions are hand tight Do not over tighten or use a pipe wrench This will damage the unions and cause leaking If the unit leaks with the unions hand tight then loosen the unions s and check the O ring seal to ensure it is properly seated 9 The acrylic surface of this bath has been provided with a protectivefilmwhichhelpsprotectthebathduringshipment and installation Additional protection may also be r...

Страница 4: ...er GFCI In the unlikely occurrence of a current imbalance in the power conductors the GFCI will interrupt the power to the bath GROUNDING IS REQUIRED Theunitshouldbeinstalledbyaqualifiedservicerepresentative and properly grounded WARNING The electrical service to the GFCI must not be interrupted by any control device Likewise the electrical service from the GFCI to the bath control should be direc...

Страница 5: ...the same time everyday See Operating the Signature Edition Air Whirlpool Touchpad on pages 8 9 REMOTE CONTROL FEATURES In addition to the main control touchpad installed on the bath deck a floating waterproof Universal Remote Control is providedwithallSignatureEditionAir Whirlpools Thisremote controlprovidesthesamecontrolfunctionsasthebath smain control console plus the bather may remotely operate...

Страница 6: ...l box must be plugged into a 120v 15 amp GFCI dedicated circuit H Pre wired power cord to the blower I Air whirlpool control box connections SIGNATURE EDITION AIR WHIRLPOOL PARTS LIST Pump Pump Control Box Blower Blower Control Box Heater Keypad Keypad Cable Control Box Stand LED Light Assembly Ozone Sanitation Unit Water Level Sensor Jason s Signature Edition Air Whirlpool system is the most adva...

Страница 7: ... jets Blowers provided on Jason Air Whirlpool baths are factory tested when assembled and again retested after installation on the Air Whirlpool bath STANDARD EDITION AUTOMATIC PURGE Fifteen minutes after the control has shut off and the bath is completely drained the blower will start again for a two minute purge cycle that dries the air channel Note that the blower light will flash during the 15...

Страница 8: ...umandMedium to High The system remembers the last speed setting on the next startup The Blower Speeds icon will light up when the blower is running The LED displays the blower speed from 10 Low or 55 Med to 99 High while the key is pressed You can reduce the auto purge idle time from 20 minutes to 10 minutes by pressing and holding the key for more than 5 seconds during the purge idle period LED L...

Страница 9: ...n again to increase the blower speed until the desired intensity is reached The blower will return to its highest speed on any mode change Option The Option icon is used to operate an optional LED light if installed Press the icon for less than two 2 seconds to turn the lights Off or On Hold the icon for more than two 2 seconds to change modes This function has a two 2 hour timer and remembers the...

Страница 10: ... commercially available plastic polish i e Novus Plastic Polish No 2 available at your Jason dealer followed by an application of acrylic paste wax Buff the surface with a clean soft cloth Do not use sandpaper steel wool or abrasive rubbing compounds Ifscratchesaretoodeeptorubout orifthedamagepenetrates the acrylic surface consult your dealer for recommendations on surface repair AIR HEATER AND AI...

Страница 11: ...cle was disabled a Remove power to the bath either by the circuit breaker or by unplugging and replugging the blower from the supply outlet PumpSystem of Air Whirlpool Bath Symptoms Possible Causes Recommended Action Pump system won t start a No power to the pump unit b Pump motor is not plugged in c Insufficient water a Reset circuit breakers and check GFCI Check fuses and replace if bad b Make s...

Страница 12: ...ators hypnotics narcotics or tranquilizers F Persons with a medical history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a physician before using an Air Whirlpool G Persons using medication should consult a physician before using an Air Whirlpool bath since some medication may induce drowsiness while other medication may affect heart rate blood...

Отзывы: