AIR FEATURES 

AirMasseur

®

 Blower 

The blower generates warm air and pushes it through 
the strategically placed air jets.  The AirMasseur 
system contains a variable speed-controlled heated 
air blower. Blowers provided on Jason baths are 
factory tested when assembled on the bath.  
 

Air ON/OFF Button  

The Air On/Off button (air 
switch activator) allows 
the user to turn the blower 
On and Off and controls 
the blower’s intensity.  
Momentarily depress the 
button to start or stop the 
air blower.  A timer will automatically stop the air 
blower after 20 minutes of operation if it is not 
stopped manually. 

 
Blower Speed 

Once the blower is On, to decrease the air output, 
press and hold the Air On/Off button until the desired 
intensity is reached, then release the button.  To 
increase the air intensity, press and hold the Air 
On/Off button until the desired intensity is reached, 
then release the button.   

 

AirMasseur

®

 Automatic Purge 

Fifteen (15) minutes after the blower is stopped, the 
blower will start again for a two (2) minute purge cycle 
that dries the air channel.  

 

 

 

 

 

REMOTE MOUNTING OF AIR BLOWER

 

The Jason AirMasseur

®

 system has been factory 

installed following ETL/UL Standard safety guidelines.  
During installation, if remote mounting of the air blower 
is desired or required, the following procedures should 
be followed. 
 

Note:

 Do no remote mount the blower more than 15 

feet [4.5m] away from the air inlet of the bath.  Choose 
a location as close as possible to the bath to ensure 
maximum efficiency. 
 

1.  The installer must determine the layout of the 

piping; exact remote mount location; and 
service access before beginning any work.  Use 
1.5” ABS or PVC plastic tubing.  Locate the 
blower in an area accessible for servicing. 

 

1. 

Note:

 A 15 foot extension cable set can be 

purchased from your Jason supplier, if needed.  
To ensure proper functioning of the system, 
avoid remote mounting in a location which 
requires more than six (6) piping direction 
changes.  A 90° direction change should be 
made up of two 45° elbows for maximum 
efficiency. 

 

2.  If the blower has been factory installed, 

disconnect the blower from the air bath 
plumbing by removing the two (2) screws on the 
check valve outlet and disconnect the short 
piece of pipe between the check valve and the 
elbow by removing the two (2) screws in the 
elbow.  [Omit this step on baths where the 
blower is not factory installed and remote 
mounting is required.] 

 

3.  Install the blower in the remote location.  The 

remote mount location ambient air temperature 
should remain at approximately 72°F [22°C] for 
optimum air heating. 

 

4.  Make sure the blower is well ventilated.  The 

blower mount should be attached firmly to the 
floor.  Piping between the remote blower 
location and the bath can be insulated using a 
minimum of ½” [13mm] thick insulation.  Attach 
new piping to the elbow of the existing piping. 

 
 
 

 

 
 

FEATURES, CONTROLS AND OPERATING INSTRUCTIONS (cont.)

 

Содержание Excel Series

Страница 1: ...installation Damage to the unit during installation will not be covered by warranty and is the responsibility of the installer ALL WARRANTY CLAIMS ON ACRYLIC SURFACE DAMAGE MUST BE MADE PRIOR TO INST...

Страница 2: ...ol anticoagulants stimulants antihistamines vasoconstrictors vasodilators hypnotics narcotics or tranquilizers F Lower water temperatures are recommended for extended use exceeding 10 15 minutes and f...

Страница 3: ...s de 10 15 minutes et pour les jeunes enfants F Puisque les temp ratures excessives ont un potentiel lev pour les f tus durant les premiers mois de la grossesse les femmes enceintes ou possiblement en...

Страница 4: ...fore servicing For baths requiring two circuits CAUTION Not Suitable for Field Installed Heater ATTENTION la temperature ambiante sous la baignoire o l quipement est install ne doit pas d passer 50 C...

Страница 5: ...her used as a hydrotherapy bath soaking bath or just taking a shower NOTE If the unit fails to operate check the breaker panel to ensure that the circuit breaker is on Check the GFCI by testing and re...

Страница 6: ...llowing procedures should be followed Note Do no remote mount the blower more than 15 feet 4 5m away from the air inlet of the bath Choose a location as close as possible to the bath to ensure maximum...

Страница 7: ...ghly after cleaning SURFACE MAINTENANCE Area with minor scratches or dull surfaces can be restored by applying commercially available plastic polish i e Novus Plastic Polish No 2 available at your Jas...

Страница 8: ...um of 72 F 22 C 3 Drain and Overflow Install the drain and overflow assembly to the bath shell according to the instructions provided with the drain and position the bath in the area of intended insta...

Страница 9: ...ce of this bath has been provided with a protective film which helps protect the bath during shipment and installation If the bath is tiled in remove the necessary portion of the film when installing...

Страница 10: ...and not interrupted by a switch Never use a switch in conjunction with a control device This will VOID THE MANUFACTURER S WARRANTY The pumps are supplied with an electrical bonding lug to allow connec...

Страница 11: ...If no voltage control is defective b Motor is not plugged into control box b Make sure plug is fully inserted into the control box outlet c Air switch Plastic air tubing disconnected or broken c Check...

Страница 12: ...nt of equipment shall be F O B point of shipment This warranty shall not apply to any merchandise which has been subject to accident alteration abuse misuse abrasives corrosion and or electrolysis imp...

Отзывы: