background image

Jason International, Inc.  •  

 

501.771.4477  

 

 

 

Page 4 of 25

 

 

 

 

Customer Service :  800.255.5766 

Copyright © 2018 Jason International, Inc.

Cautionary Warnings (English/French)

CAUTION: Ambient temperature under the bath where equip-
ment is installed must not exceed 122°F (50°C).

WARNING: Any modification to the equipment is not recom-
mended and will void the Manufacturer’s warranty.

DANGER - RISK OF ELECTRIC SHOCK: 

Connect only to a cir-

cuit protected by a Ground Fault Circuit Interrupter (GFCI). In the 
unlikely occurrence of a current imbalance in the power conduc-
tors, the GFCI will interrupt the power to the bath.

WARNING: The electrical service to the GFCI must not be 
interrupted by any control device. Likewise, the electrical 
service from the GFCI to the bath control should be direct 
and not interrupted by a switch. Never use a switch in con-
junction with a control device.
This will VOID THE MANUFACTURER’S WARRANTY.

DANGER - Do not alter the factory installed wiring. All build-
ing materials and wiring should be routed away from the 
equipment or other heat-producing components of the unit.

CAUTION: 

Keep hair, towels, and clothing away from the suction 

fitting whenever the equipment is On. Never operate the equip-
ment with the suction cover off, doing so voids the manufacturer’s 
warranty--it is a safety cover designed to eliminate the potential 
of hair and body entrapment.

ATTENTION: la temperature ambiante sous la baignoire où 
l’équipement est installé ne doit pas dépasser 50°C.

AVERTISSEMENT : Toute modification de l’équipement n’est 
pas recommandé et annulera la garantie du fabricant.

DANGER - RISQUE DE CHOC ÉLECTRIQUE : 

Connecter 

uniquement à un circuit protégé par un disjoncteur (GFCI). Dans 
l’éventualité peu probable d’un déséquilibre de courant, le GFCI 
coupera le courant du bain.

AVERTISSEMENT : Le service électrique au GFCI ne doit 
pas être interrompu par un dispositif de contrôle. De même, 
le service électrique du GFCI au contrôle de bain doit être 
direct et ininterrompu par un controlleur. Ne jamais utiliser 
un commutateur en conjonction avec un dispositif de com-
mande.
Cela annulera la garantie du fabricant.

DANGER - Ne pas modifier le câblage installé en usine. 
Tous les matériaux de construction et câblage doivent être 
éloignés de toutes sources de chaleur moduites par le abin.

ATTENTION : 

Garder les cheveux, les serviettes et les vête-

ments à distance du raccord d’aspiration lorsque l’appareil est 
allumé. Ne jamais faire fonctionner l’équipement avec l’aspiration 
couvrir off, cela annule la garantie - c’est un dispositif de sécurité 
conçu à éviter l’occulusion du corps et des cheveux.

AVERTISSEMENT: Avant d’opérer le bain consulter les 
instructions à la fin de ce manuel concernant les risques 
d’incendie, de choc électrique ou de blessure ce proprié-
taire.

AVERTISSEMENT: Évitez les hauts niveaux d’humidité dans 
votre maison. Les Moisissures, champignons et certaines 
bactéries peuvent être nocifs pour la santé et se dévelop-
per dans ces zones; par conséquent, toutes les précautions 
doivent être prises pour vous assurer que votre plomberie, y 
compris les baignoires, bains thérapeutiques, ou les douch-
es ne deviennent pas une source de forte humidité due à 
une mauvaise installation ou de fuites.

AVERTISSEMENT: Toujours couper l’alimentation électrique 
au panneau de service électrique avant la maintenance.

ATTENTION :

 Risque de choc électrique - Deux interrupteurs de 

déconnexion sont nécessaires pour mettre l’unité hors tension 
avant l’entretien. [Pour les bains nécessitant deux circuits]

ATTENTION: Ne convient pas aux appareils de chauffage 
installés sur le terrain

WARNING: Before operating refer to the instructions at the 
end of this owner’s manual pertaining to the risk of fire, elec-
tric shock, or injury to persons.

WARNING: Avoid high humidity levels in your home. Mold, 
mildew, fungi and bacteria which may be harmful to health 
thrive in areas with continued high humidity levels; there-
fore, every precaution should be taken to make sure your 
plumbing fixtures including bathtubs, therapy baths, or 
showers do not become a source of high humidity due to 
improper installations or leaks.

WARNING: Always turn off power at the main electrical ser-
vice panel when servicing the bath

CAUTION: Risk of Electric Shock - -

Two disconnect switches 

are required to de-energize the unit before servicing.  [For baths 
requiring two circuits]

CAUTION: Not Suitable for Field-Installed Heater

Содержание AirMasseur

Страница 1: ...and carrier Always file a freight claim promptly The installer is responsible for insuring that the unit is free from defects or shipping damage In the event of a problem DO NOT install the unit Jason...

Страница 2: ...l anticoagulants stimulants antihistamines vasoconstric tors vasodilators hypnotics narcotics or tranquilizers F Lower water temperatures are recommended for extended use exceeding 10 15 minutes and f...

Страница 3: ...plus de 10 15 minutes et pour les jeunes enfants F Puisque les temp ratures excessives ont un potentiel lev pour les f tus durant les premiers mois de la grossesse les femmes enceintes ou possiblement...

Страница 4: ...la garantie du fabricant DANGER Ne pas modifier le c blage install en usine Tous les mat riaux de construction et c blage doivent tre loign s de toutes sources de chaleur moduites par le abin ATTENTIO...

Страница 5: ...r to the Trouble Shooting Guide section of this manual If the unit still fails to operate and is out of warranty contact an authorized service technician for repair If the unit is within the warranty...

Страница 6: ...low water tem perature sensors and Jason s Bluetooth Sound Immersion system WHIRLPOOL FEATURES Jason s Whirlpool hydrotherapy bath utilizes Perfect Pres sure Perfect Flow jets that are directed at ke...

Страница 7: ...CONTROLS AND OPERATING INSTRUCTIONS cont STANDARD PREMIER EDITION ELECTRONIC CONTROLS ICONS POWER Icon WHIRLPOOL Icon AIRMASSEUR Icon MICROSILK Icon LED Icon Premier Signature PILLOW Icon Optional Bl...

Страница 8: ...e will start with the next press indicated by a rapid flash of the icon Pressing the icon again will turn the neck jets OFF and the icon will turn WHITE Once the system returns to Standby mode the ico...

Страница 9: ...minutes the blower will turn on for two 2 minutes to allow the plumbing lines to drain This will be indicated by the AIRMASSEUR icon turning solid GREEN This purge cycle can be canceled by pressing an...

Страница 10: ...c FEATURES CONTROLS AND OPERATING INSTRUCTIONS cont SIGNATURE EDITION ELECTRONIC CONTROLS ICONS WHIRLPOOL Icon AIRMASSEUR Icon MICROSILK Icon PILLOW Icon Optional Blower SPEED Icon LED Icon Premier Si...

Страница 11: ...PEED icon to change an option For example press and release the AIRMASSEUR icon to change from Product Test to the Temperature option Press and release the SPEED icon to change the temperature display...

Страница 12: ...g lines to drain The AIRMASSEUR icon is used to activate the blower and the 20 minute timer CONSTANT Mode will start with the first press and CONST AIR will be displayed WAVE Mode will start with the...

Страница 13: ...s Rinse the bath thoroughly after cleaning SURFACE MAINTENANCE Area with minor scratches or dull surfaces can be restored by applying commercially available plastic polish i e No vus Plastic Polish No...

Страница 14: ...level on top of the deck on both ends and front of the bath Jason baths are designed to be support ed at the base of the bath If the floor is smooth and level the bath s Level Form Base will provide...

Страница 15: ...ath is positioned in the area of intended installa tion cut the equipment support strap s to allow the equip ment to rest firmly level with the bottom of the bath on the floor We recommend securing th...

Страница 16: ...t of the bath Choose a loca tion as close as possible to the bath to ensure maximum efficiency 1 The installer must determine the layout of the pip ing exact remote mount location and service ac cess...

Страница 17: ...lectrical equipment and exposed metal in the area as may be required by local code Note The air blower s exterior housing is made of all plastic ma terials and does not require a bonding conductor Gro...

Страница 18: ...Cable CBL 366 LED Cable CBL 366 Keypad Cable CBL 372 MS Pump 1 2 J SON t d dt h K D d s W D E D E D W TRANSDUCER BLACK RED BLACK RED BLUETOOTH AMPLIFIER Optional Bluetooth Sound Immersion Transducers...

Страница 19: ...A9a Gincmi Pinc Mloi Drooidvlrot Prv Vtie LED Cable CBL 366 LED Cable CBL 366 Keypad Cable CBL 372 Mrce 1 Ncmi Pinc Mloi Drooidvlro Cmrzis 1 2 Keypad IDU 264 J SON Ozone D d s W D E h t d dt D E K TRA...

Страница 20: ...ldi Heater 1 2 J SON t d dt h K D d s W D E tW W D E d s W D E TRANSDUCER BLACK RED BLACK RED BLUETOOTH AMPLIFIER Optional Bluetooth Sound Immersion Transducers installed on bath Bluetooth amp supplie...

Страница 21: ...9a Gincmi Pinc Mloi Drooidvlrot Ozone Ncmi Pinc Mloi Drooidvlro LED Cable CBL 366 LED Cable CBL 366 Keypad Cable CBL 372 1 2 Ncmi Pinc Mloi Drooidvlro Cmrzis MS Pump Keypad IDU 264 J SON D D E s d W E...

Страница 22: ...nc Mloi Drooidvlro MS Pump Keypad IDU 264 J SON h D t d dt D E s d W E K D E tW W D E d s W D W TRANSDUCER BLACK RED BLACK RED BLUETOOTH AMPLIFIER Optional Bluetooth Sound Immersion Transducers instal...

Страница 23: ...lro Vr Eieldcvie 120 60I 20B HGDL Ssrvidvie Tiswldi Heater 1 2 Ncmi Pinc Mloi Drooidvlro Cmrzis Keypad IDU 264 J SON D t d dt D E s d W E h K D E tW W D E d s W Standard Edition Premier Edition Signat...

Страница 24: ...rted into the control box outlet c Check and reconnect if necessary Equipment does not manually shut off a Control defective a Refer to installer dealer Equipment shuts off by itself or before set tim...

Страница 25: ...y validation card The pre addressed warranty registration card MUST be filled out by the purchaser within thirty 30 days from purchase and mailed to Jason International Inc in order for the limited wa...

Отзывы: