![Jasic TIG200 Скачать руководство пользователя страница 46](http://html2.mh-extra.com/html/jasic/tig200/tig200_manual_3589425046.webp)
Page 46
disassembly and assembly
The argon gas is impure
Replace with qualified argon gas
The gas flow is too large or small
Adjust the gas flow properly
Arc is started
between the
electrode holder
and tungsten
electrode or
welding torch
The electrode holder and
tungsten electrode have poor
contact, or arc is started when the
tungsten electrode contacts the
base metal
Replace the electrode holder or
repair
The electrode holder and welding
torch have poor contact
Connect the electrode holder and
welding torch properly
9. Troubleshooting
Warning! Before arc welding machines are dispatched from the factory, they
have already been checked thoroughly. The machine should not be tampered
with or altered. Maintenance must be carried out carefully. If any wire
becomes loose or is misplaced, it maybe potentially dangerous to user! Only
professional maintenance personnel should repair the machine!
Ensure the power is disconnected before working on the machine. Always
wait 5 minutes after power switch off before removing the panels.
9.1. Common malfunction analysis and solution
The symptoms listed here may be related to the accessories, gas,
environmental factors, and power supply you use. Please try to improve the
environment and avoid such situations.
Elimination of general problems in MMA
Symptom
Reasons
Troubleshooting
After startup, the fan
does not turn or the wire
feeding speed is
abnormal
The air temperature
may be too low or
the fan may be
damaged
If the temperature is too low, leave the
machine to work for a while. The
temperature in standby will rise the fan
and resume normal operation. If it is still
not working, it is necessary to replace
the fan.
MMA
Hard to start
the arc
Arc hot start current
is low
Or the hot start time
is short
Increase arc start current or arc start
time
Unstable arc or
excessive
penetration
Arc start current is
high
Or the arc start time
Reduce arc start current or start time
appropriately
Содержание TIG200
Страница 11: ...Page 11 Wireless indicator Pairing of wireless simple remote controller Electric shock risk warning...
Страница 53: ...Page 53 Appendix 3 List of common spare parts...
Страница 56: ...Page 56...
Страница 59: ...Page 59...