![Jasic TIG200 Скачать руководство пользователя страница 26](http://html2.mh-extra.com/html/jasic/tig200/tig200_manual_3589425026.webp)
Page 26
time; after releasing the trigger, the machine will drop to finish current from peak current after
the preset down-slope time, then the arc will extinguish, and the operation will end after the
post-flow time.)
3) If the indicator
is on, it indicates that the machine is in 4T mode.
(In 4T mode, after pressing the torch trigger, the machine will start a high-frequency arc after
the pre-flow time, then output the initial current; after releasing the trigger, it will reach the
peak current from the initial current after the preset up-slope time; after pressing the trigger
again, it drops to finish current from peak current after the preset down-slope time; and after
releasing the trigger again, the arc extinguishes and the operation ends after the post-flow
time.)
4) If the indicator
is on, it indicates the machine is in repeat operation mode.
(In repeat mode, after pressing the torch trigger, the machine will start a high-frequency arc
after the pre-flow time, and reach the peak current from the initial current after the preset
up-slope time; after releasing the trigger, the machine will drop to finish current from peak
current after the preset down-slope time; after pressing the trigger again, it rises to peak
current after the preset up-slope time; and after releasing the torch trigger again, it drops to
the finish current after the preset down-slope time, and so on. If the torch trigger is quickly
double-tapped within 300ms, the arc extinguishes and the process ends after the post-flow
time.)
5) If the indicator
is on, it indicates the machine is in spot welding mode.
(In spot welding mode, after pressing the torch trigger, the machine will start a high-frequency
arc after the pre-flow time, then output welding current. After repeatedly pressing the torch
trigger, the arc automatically extinguishes after the pre-set spot welding time. Then, to restart
the arc, press the trigger again. If the trigger is released before the set spot welding time, the
arc will extinguish immediately.)
6.1.12 Use of remote controller
6.1.12.1 Wireless remote controller
1
)
Wireless pairing:
Before welding, press and hold the panel remote control function
button
and the pairing button of the wireless simple remote controller at the same time
for 2 seconds to pair the wireless remote controller. During pairing, the blue wireless receiver
module indicator
flashes; after successful pairing, the remote control mode indicator
will be on. At the same time, the blue indicator
of the wireless receiver module will
remain on and the welder display window will display "OK".
2
)
Disconnecting the wireless connection:
After the remote controller is successfully
paired, press and hold the pairing button of the wireless remote controller, or the remote
control function button on the panel, and the wireless connection will be disconnected. After