EVOLVE 200 USER MANUAL
18
Rotate KNOB2 to adjust the arc force %.
SETTING MENU
Push the SETTING button to enter in the setting menu.
SELECT the sub menu by knob1 and confirm by pushing the
knob1.
- Technical Parameter (See Table 2.2)
- JOB menu: select the job
- MACHINE INFO: can show the machine SN and more
information.
- RESTORE FACTORY: restore default settings of the working data in the selected welding section.
POWER LIMITATION
The Power limitation function improves the quality of welding in
MMA mode.
It can be adjusted from 0 (max limitation) -100% (OFF).
With this parameter, you can have a limitation of the output
power through the check of the output voltage. If the voltage
exceeds the nominal value expected for the arc [U
2
=(20+0,04
2
I
)V] of the percentage set by the Power Limit,
the current drops in proportion in order to keep the value of
output power constant.
ANTI
-
STICKING ON /OFF:
It prevents the electrode from sticking to the part while welding is being performed.
Set ON /or OFF by knob2 and confirm by pressing knob2.
Содержание EVOLVE 200
Страница 1: ...EVOLVE 200 USER MANUAL EVOLVE 200 USER MANUAL REV 20201219 ...
Страница 18: ...EVOLVE 200 USER MANUAL 16 ...
Страница 43: ...EVOLVE 200 USER MANUAL 41 4 1 Remote control connection ...
Страница 50: ...EVOLVE 200 USER MANUAL 48 ...
Страница 51: ...EVOLVE 200 USER MANUAL 49 Appendix 2 MACHINE SCHEMATICS ...
Страница 53: ...EVOLVE 200 USER MANUAL 51 ...
Страница 54: ...EVOLVE 200 USER MANUAL 52 Ref 3 Ref 4 Ref 5 3 5 10 2 7 ...