Jasic 315P AC/DC Digital Скачать руководство пользователя страница 4

Safety Precautions

1

These general safety norms cover both arc welding 
machines and plasma cutting machines unless 
otherwise noted.

The  equipment  must  only  be  used  for  the  purpose  it  was 
designed  for.  Using  it  in  any  other  way  could  result  in 
damage or injury and in breach of the safety rules.

Only suitably trained and competent persons should use the 
equipment.  Operators  should    respect  the  safety  of  other 
persons.

Prevention against electric shock

The equipment should be installed by a qualified person and 
in  accordance  with  current  standards  in  operation.It  is  the 
users  responsibility  to  ensure  that  the  equipment  is 
connected  to  a  suitable  power  supply.  Consult  with  your 
utility supplier if required

If  earth  grounding  of  the  work  piece  is  required,  ground  it 
directly with a separate cable. 

Do not use the equipment with the covers removed.

Do  not  touch  live  electrical  parts  or  parts  which  are 
electrically charged. 

Turn o

 all equipment when not in use. 

Cables  (both  primary  supply  and  welding)  should  be 
regularly  checked  for  damage  and  overheating.  Do  not  use 
worn, damaged, under sized, or poorly jointed cables.

Ensure that you wear the correct protective clothing, gloves, 
head and eye protection. 

Insulate yourself from work and ground using dry insulating 
mats or covers big enough to prevent any physical contact 
with the work ground. 

Never touch the electrode if you are in contact with the work 
ground, or another electrode from a di

erent machine. 

Do not wrap cables over your body. 

Ensure that you take additional safety precautions when you 
are  welding  in  electrically  hazardous  conditions  such  as 
damp  environments,  wearing  wet  clothing,  and  metal 
structures.  Try  to  avoid  welding  in  cramped  or  restricted 
positions. 

Ensure  that  the  equipment  is  well  maintained.  Repair  or 
replace damaged or   defective parts immediately. Carry out 
any  regular  maintenance  in  accordance  with  the 
manufacturers instructions.

Safety against fumes and welding gases

Locate the equipment in a well-ventilated position.

Keep your head out of the fumes. Do not breathe the fumes. 

Ensure the welding zone is in a well-ventilated area. If this is 
not  possible  provision  should  be  made  for  suitable  fume 
extraction. 

If ventilation is poor, wear an approved respirator. 

Read  and  understand  the  Material  Safety  Data  Sheets 
(MSDS’s)  and  the  manufacturer’s  instructions  for  metals, 
consumable, coatings, cleaners, and de-greasers. 

Do not weld in locations near any de-greasing, cleaning, or 
spraying operations.  Be aware that heat and rays of the arc 
can  react  with  vapours  to  form  highly  toxic  and  irritating 
gases. 

2

Содержание 315P AC/DC Digital

Страница 1: ...cleaning width Remote control interface AC function for aluminium and aluminium alloys DC TIG function for carbon steel copper and non ferrous metals Smooth arc and stable welding performance Integrat...

Страница 2: ...Operator Manual www jasic co uk TIG Series TIG 200P AC DC Digital JT 200D TIG 315P AC DC Digital JT 315D...

Страница 3: ...pplier of equipment in the UK and our products are supported by our extensive service network Call your distributor in the unlikely event of a problem occurring Please record below the details from yo...

Страница 4: ...e protection Insulate yourself from work and ground using dry insulating mats or covers big enough to prevent any physical contact with the work ground Never touch the electrode if you are in contact...

Страница 5: ...an may cut fingers and hands and snag garments Protections and coverings may be removed for maintenance and controls only by qualified personnel after first disconnecting the power supply cable Replac...

Страница 6: ...etwork at the public network connection point must be applied to these systems In this case the installer or the user is responsible for ensuring the equipment can be connected consulting the electric...

Страница 7: ...igent digital control so it is not sensitive to the change of parameters of components That is the performance of welding machine will not be a ected by the change of the parameters of certain compone...

Страница 8: ...cation protocol Available as a special order Perfect automatic recording function All data such as cumulative start up times cumulative running time cumulative welding time cumulative TIG welding time...

Страница 9: ...range MMA A DC 10 200 AC 20 200 DC 10 300 AC 20 300 Arc force current range MMA A 0 100 0 100 Initial current range A DC 10 200 AC 20 200 DC 10 320 AC 20 250 Peak current range A DC 10 205 AC 30 205...

Страница 10: ...ch connector 5 Remote control connector 6 Positive power connector 7 Mains switch 8 Adjustment control Front view JT 315D 1 Control panel 2 Negative output socket 3 Torch gas connector 4 Torch switch...

Страница 11: ...Data plate 10 Power cable input 11 Shield gas input connector 12 Serial number Rear View JT 315D 9 Data plate 10 Power cable input 11 Water input connector 12 Shield gas input connector 13 Serial numb...

Страница 12: ...arameters and users may perform welding conveniently with these parameters C The digital meter displays the software version after the machine is started and displays the pre set current 2 seconds lat...

Страница 13: ...least to avoid arc breaking due to overly low current and should not be higher than the pre set current The foot control is e ective only in TIG mode 1 Pre flow time 7 Pilot arc current 2 Initial cur...

Страница 14: ...ilable for this machine Concept hints Parameter group 5 parameter groups 1 5 are available for users to save the welding parameters based on a welding application and all parameters in all the six wel...

Страница 15: ...erally 1 5 3 times the welding current and the arc ignition time is 0 02 0 05s When in low current ignition mode the arc ignition current is generally 0 2 0 5 times the welding current and the arc ign...

Страница 16: ...ng it will lead to a waste of shield gas if it is too short it will result in the oxidation of weld bead and electrode When in AC TIG or for special materials the time should be longer Upslope time tr...

Страница 17: ...between 10 and 90 TIG spot welding Select TIG operation mode 1 and TIG spot welding function can be achieved Spot welding is available in all the four TIG welding modes Please note that the spot weld...

Страница 18: ...de no Operation Torch trigger operation and current curve 0 Follow mode Push the torch trigger arc is ignited and current rises to the pre set value Release it arc stops 1 1T Spot welding mode Push th...

Страница 19: ...again and then turn to If push the torch trigger and release it at once arc will stop 7 Cycle single operation mode with initial current Push the torch trigger arc is ignited and current reaches the i...

Страница 20: ...se it current drops to pilot arc current value Push it again arc stops 13 Double operation 3T mode Push the torch trigger arc is ignited and current rises gradually The torch trigger can be released a...

Страница 21: ...t again current rises to the preset value and then turn to If push the torch trigger and release it at once or release the torch trigger and push it at once arc will stop Note Preset value is the peak...

Страница 22: ...connected to the negative terminal and the work return to the positive terminal MMA welding DC Insert the cable plug with electrode holder into the socket on the front panel of the welding machine and...

Страница 23: ...ding to the relevant content in this manual and TIG welding can be carried out The arc ignition mode of this machine is non contact arc ignition During welding the parameter display meter displays the...

Страница 24: ...o before opening the case NOTE When the inverter welder is powered on defective components may explode or lead to explosion of other components Wear face guard and long sleeved clothing when maintain...

Страница 25: ...th a higher rated current holder MMA Arc is easy to break Arc breaking voltage is too low Increase the arc breaking voltage TIG There is no current output when pushing the torch trigger Welding can be...

Страница 26: ...o the power cord which is connected to other electric appliances of serious interference Other malfunction Other malfunction Contact the service centre Type Alarm Automatic response Cause Solution Ove...

Страница 27: ...Electrical schematic 7 25...

Страница 28: ...Parts list 8 JT 200D 26...

Страница 29: ...0040578 Top board 15 10022057 Fan 32 10038699 Central board 16 10016389 Connector for water 33 10020826 Power line 17 10021912 Line button 27 No Part no Description No Part no Description 1 10014869 F...

Страница 30: ...JT 315D 28...

Страница 31: ...JT 200D JT 315D DIGITAL AC DC PULSE TIG MMA WELDING MACHINE Order code JT 200D JT 315D Wilkinson Star Limited Issue 1 January 2014 Product is subject to change without notice xxix...

Страница 32: ...rigger and release it at once Release the torch trigger and push it at once Push the torch trigger twice within 0 5s or Release the torch trigger twice within 0 5s or These are the general description...

Страница 33: ...ration stipulations 100 codes are classified and explained in Attached Table 2 based on their functions and characteristics and users should fully understand all those For welding machine operation mo...

Страница 34: ...s 100 kinds of operation codes are available for this machine there is more than one code sequence to achieve the specific operation function and users only need to choose one of them It should be str...

Страница 35: ...ode with initial current 8 Inner timing operation mode 9 Outer timing operation mode 10 Cycle double operation mode without initial current 11 Cycle double operation mode with initial current 12 Singl...

Страница 36: ...quartic operation stop arc 9X Immediate transfer code X 0 Turn to next step X 0 Turn to Step X X 0 9 The definition of order X The definition of order X The definition of order X The definition of or...

Страница 37: ...d you can press the parameter display selecting key and the operation mode LED flashes This means you have entered into code editing state Code no selecting and code content editing After you enter in...

Отзывы: