Troubbleshooting
No irrigation
1/ Verify power supply
2/ Verify wiring
No communication
Verify proper network is selected in your smartphone
settings
Schedules Shifted
Controller had lost time after a long period of
power failure and need to be resynchronize with
the App.
Meaning of the LED on the front of the module
LED status
Meaning
Red fixed during 5 mns
Red fixed during 2 mns
Installation mode : Controller is waiting initial
configuration
Installation mode : Controller can be reconfigured
if needed after plugging power again
2 x red flashing
3 x red flashing
5 x red flashing
Following a power failure, the module lost time.
Following a power failure, controller had lost
connexion to its Wi-Fi access point
The module is out of the installation mode after 5
minutes withoot being set.
Green Fixed
Green flashnig
Run Mode
Irrigation in progress
Off
No power supply