12
En
3
/
HOW tO DEtERMInE tHE VOLuME OF MY tAnk :
Using the table below :
1.
Choose your
RUN TIME
watering.
2.
Choose your watering frequency.
Total flow (L/h) distributed according to watering frequency and duration :
FREQUENcY
RUN TIME
30 sec 1 min
3 min
5 min
6 min
7 min
8 min 10 min 12 min 15 min
1 hour
1,8
3,6
10,8
18
21,6
25,2
28,8
36
43,2
54
3 hours
0,6
1,2
3,6
6
7,2
8,4
9,6
12
14,4
18
6 hours
0,3
0,6
1,8
3
3,6
4,2
4,8
6
7,2
9
12 hours
0,15
0,3
0,9
1,5
1,8
2,1
2,4
3
3,6
4,5
24 hours
0,075
0,15
0,45
0,75
0,9
1,05
1,2
1,5
1,8
2,25
48 hours
0,075
0,15
0,45
0,75
0,9
1,05
1,2
1,5
1,8
2,25
3 days
0,075
0,15
0,45
0,75
0,9
1,05
1,2
1,5
1,8
2,25
4 days
0,075
0,15
0,45
0,75
0,9
1,05
1,2
1,5
1,8
2,25
5 days
0,075
0,15
0,45
0,75
0,9
1,05
1,2
1,5
1,8
2,25
6 days
0,075
0,15
0,45
0,75
0,9
1,05
1,2
1,5
1,8
2,25
7 days
0,075
0,15
0,45
0,75
0,9
1,05
1,2
1,5
1,8
2,25
The flow rates shown in this table represent the total distributed by the SK10 programmer, depending on the
watering duration and frequency for 1 day. The total flow is equitably divided by the number of drippers installed (for
example : for a flow rate of 0.75 L/h : if I install 10 drippers = 0.75 / 10 = 0.075 L/h per dripper / if I install 3 drippers
= 0.75 / 3 = 0.25 L/h per dripper / etc...).
The rates indicated in dark are not recommended during your programming.
3.
How long do you have to be away ?
4.
Calculate the number of watering needed during your absence :
number of waterings =
away time (in days)
frequency (in days*)
*Use the table "Time -> day converter" to know your frequency in hours -> in day.
cALcuLAtIOn OF tHE VOLuME OF WAtER nEcESSARY :
volume = water flow x number of waterings
check the flow rate of each dripper to ensure that your plants will not run out
of water.
To balance the watering between your large and small plants, you can install
2 drippers on large plants.
!
Example :
1.
Duration : 5 min
2.
Frequency : every 24 hours
3.
Absence : 15 days
4.
Number of watering : 15 days / 1 day =
15 waterings
volume =
0,75 x 15 =
11,25 liters
I must therefore provide a tank with at least 11.25 liters of water.
Flow rate =
0,75 l/h
Time converter -> day
1 hour
0,04 day
3 hours
0,125 day
6 hours
0,25 day
12 hours
0,5 day
24 hours
1 day
48 hours
2 days
Содержание SUMMER KIT
Страница 46: ...46 EL Summer Kit 10 1 KIT 2 x 1 x 1 x 1 x 1 USB x 1 x 1 x 10m x 10 x 2 x 10 2 x 10...
Страница 48: ...48 EL LED 1 4 5 USB USB 2 USB Adaptateur USB 1 2 4 5 6 10 10 30 USB...
Страница 49: ...49 EL 1 2 6 1 2 52 3...
Страница 53: ...53 RU Summer Kit 10 1 2 x 1 x 1 x 1 x 1 USB x 1 x 1 x 10m x 10 x 2 x 10 2 x 10...
Страница 55: ...55 RU 1 4 5 USB USB 2 USB Adaptateur USB 1 2 4 5 6 10 10 30 USB...
Страница 56: ...56 RU 1 2 6 1 2 59 3...
Страница 67: ......