4.  When heater is aimed at the right angle fasten the bolts on side of heater and bracket to 

keep heater in angled position; 

5. 

CAUTION

: For residential and public heating: mount heater at 2.4m or 8ft above the floor 

surface or grade. (Figures 2 and 3) 

 

 

(Figure 2)

 

 

(Figure 3) 

 

 

6.  (For Industrial and special applications: heater positioning will depend on application and 

design requirements);  

7.  For wall mounting position heater at 45 to 55 degree angle to the floor (see figure 2); 
8.  For ceiling mounting aim heater straight down to floor (see figure 3); 
9.   Never install the heater directly at flammable surface within surface mounting distance; 
10. Do not use the heater in non-ventilated and dusty environment to avoid damage to the 

element; 

Содержание DELUXE 500

Страница 1: ...e cord Never use the cord for carrying pulling or unplugging the heater 5 When using the heater outdoors use an extension cord suitable for outdoor use 6 Do not cover or obstruct the heater while it i...

Страница 2: ...ooden furniture paper curtains or clothes at least 3ft away from the front of heater and 1ft from the side top and rear 17 CAUTION Heater can be used outside and in damp conditions but must be shelter...

Страница 3: ...e 3 6 For Industrial and special applications heater positioning will depend on application and design requirements 7 For wall mounting position heater at 45 to 55 degree angle to the floor see figure...

Страница 4: ...it complies with local regulations and heater is connected to electrical wiring with suitable circuit breakers 14 For Factories Halls or larger areas multiple heaters can be installed in parallel wiri...

Страница 5: ...5 Unscrew the 3 screws on the side plate by the on off switch 6 Gently pull the side plate outward together with the electrical connector box compartment and element holder with element 7 Disconnect t...

Страница 6: ...FICATIONS WARRANTIES All Japidi Energy Infrared Heaters are manufactured in Canada with the following specifications Certified to CSA 22 2 No 46 M1988 UPD 3 UL 2021 UL 1278 9 06 MODEL DELUXE 500 500W...

Страница 7: ...L SUPPLY CABLE AWG 14 3 105 C AWG 14 3 105 C AWG 14 3 105 C AWG 14 3 105 C SAFETY GRID 5 bars Stainless Steel 5 bars Stainless Steel 5 bars Stainless Steel 5 bars Stainless Steel APPLICATIONS Indoor O...