4-73
4.15.9.4 Displaying the software version
The software version, serial number and bar code number of the display and sensor unit can be
displayed.
It is only JLR-4341/JLR-4340 that the serial number and bar code number of the sensor unit can be
displayed.
Software version
Serial number
Bar code number
(Management number in the factory)
1. Refer to "4.15.1 Change to a maintenance mode" and display a maintenance menu.
1) Display
2. Select “MAINTENANCE”, “SOFT VERSION”, and “DISPLAY VER” in this order by using
.
2) Sensor
2. Select “MAINTENANCE”, “SOFT VERSION”, and “SENSOR VERSION” in this order by using
.
4.15.10 Performing a Master Reset (Reset)
The GPS sensor, display or both can be reset
When master reset is performed, the setting values are reset to the default values. It is recommended
to keep the records of the setting values before performing master reset.
However, the following items are not reset.
Model, RS-485ID, dimmer control unit setting, dimmer group
To reset the display, select "DISPALY" or EXCEPT FOR LIST"
Master reset can be selected for the following equipment.
1) DISPLAY RESET: The display unut is reset.
DISPLAY: Everything (include the waypoint and route klist) will be reset
EXCEPT FOR LIST: Everything (except the waypoint and route klist) will be reset
2) RECEIVER RESET: Sensor unit is reset.
3) ALL RESET: The sensor and display unit (including list) is reset
1. Refer to "4.15.1 Change to a maintenance mode" and display the maintenance menu.
2. Press
the
key to select "MASTER RESET," and press the
key.
3. Press
the
key to select qeuipment and press the
key.
1) DISPLAY only (including list)
4. Select "DISPLAY RESET" and "DISPLAY" in order.
2) DISPLAY only (other than list)
4. Select "DISPLAY RESET" and "EXCEPT FOR LIST" in order.
3) SENSOR only
4. Select "RECEIVER RESET".
3) SENSOR and DISPALY
4. Select
"ALL
RESET".
Procedure
Procedure
Содержание JLR-7900
Страница 2: ......
Страница 11: ...ix...
Страница 16: ......
Страница 20: ...1 4 1 4 Construction NWZ 4610 Display Unit Unit mm Mass Approximately 0 8 kg NWZ 4610 Desktop type...
Страница 23: ...1 7 NBD 577C Power Supply Outline Drawing Unit mm Mass Approximately 5 4 kg...
Страница 27: ...1 11 NQA 4351 Output Buffer Outline Drawing Unit mm Mass Approximately 0 8 kg...
Страница 29: ...1 13 NCZ 1663 Select Switch Unit mm Mass Approximately 0 2 kg...
Страница 30: ...1 14 NCZ 1663 Select Switch Flush Mounting Unit mm Mass Approximately 0 2 kg...
Страница 31: ...1 15 NCZ 1537B Select Switch Flush Mounting Unit mm Mass Approximately 0 55 kg...
Страница 32: ...1 16 CQD 10 Junction Box Outline Drawing Unit mm Mass Approximately 1 1 kg 4 7 5 Installation Screw M6...
Страница 33: ...1 17 NKG 94 Printer Outline Drawing Unit mm Mass 2 2 kg or less Printer Rack...
Страница 38: ...2 4...
Страница 42: ...3 4...
Страница 138: ...6 10 Required installation space Unit mm Mount bottom 285 or more 190 or more 190 or more...
Страница 158: ...6 30...
Страница 160: ...7 2...
Страница 162: ...8 2...
Страница 181: ......
Страница 182: ......
Страница 183: ......