3 - 30
emPC-CX+
(
System Reference
Manual)
System Control
©
Janz Tec AG
Rev. 1.2
TS1
Pointer 20 (16bit, rw)
15
0
TS1
RESET:
Restored from EEPROM
TS1
TS1 is the shutdown timeout for the system (the COM Express module).
Once a shutdown has been triggered, the PMON firmware waits for the
system to shut down (monitored by COM Express SUS_S3 signal). If a
shutdown has not been detected after TS1 expires, then a system reset
is applied and power is turned off one second later.
TS2
Pointer 21 (16bit, rw)
15
0
TS2
RESET:
Restored from EEPROM
TS2
The system is off (and a minimum off time of 2 seconds has elapsed) and
VS is > VS0+VHYST for longer than TS2, then the system is turned on.
The power supply is turned on, and if the COM Express module does not
start automatically, a single power button event is generated to force turn
on.
TS3
Pointer 22 (16bit, rw)
15
0
TS3
RESET:
Restored from EEPROM
TS3
A system shutdown is inhibited until the system is running for more than
the time programmed by TS3. This can be used to prevent a shutdown
during operating system bootup phase, when the time set by TS0 might
not be enough to perform a proper shutdown.
TS4
Pointer 23 (16bit, rw)
15
0
TS4
RESET:
Restored from EEPROM
TS4
Do not write to this register.
TEMP
Pointer 32 (16bit, ro)
15
0
TEMP
TEMP
System temperature sensor readout. Temperature data is read as two’s
complement data in units of 1/10 degrees Celsius.
Register reading
Temperature/deg. C
0b0000001001010000
25.0
0b0000000000001010
1.0
0b0000000000000000
0.0
0b1111111111110110
-1.0
Содержание emPC-CX+