background image

POTSwap v1.00 User Manual JA16-UM

    

 Page 10    Rev: P09    Date: 01/03/18

© Copyright 2020 Janus Remote Communications   

Specifications subject to change without notice

   All Rights Reserved   See website for latest revision.    Not intended for life support applications.

 

4. Configuration continued

CONFIGURATION PARAMETERS continued

GSM TTY Mode       

0-1 

TTY MODE enable 

 

 

 

 

 

0 = TTY mode disabled 

 

 

 

 

 

1 = TTY mode enabled 

 

 

 

 

 

Improves in-band DTMF transport under 

 

 

 

 

 

certain circumstances 

SLIC ADC Gain       

0-8 

Sets outbound audio gain during the initial outbound DTMF 

 

 

 

 

dialing. Corrects for distortion using some auto dialers.

SLIC DAC Gain       

0-8 

Sets inbound audio gain. Should be set at 4.

Loop Current Limit

4

 

0-7 

Sets the telephone loop current limit, from 20mA (0) to 41mA (7)

 

 

 

 

in 3mA steps.  Default is 26mA (2).

Loop Closure Sensing Type

3

 

0-1 

Sets loop closure (off-hook) sensing type.

 

 

 

 

 

0 = current sensing 

 

 

 

 

 

1 = voltage sensing 

 

 

 

 

Use 0 (current sensing) for applications using ringer loads of 

 

 

 

 

REN=1 or less.  Use 1 (voltage sensing) for ringer loads of 

 

 

 

 

REN>1, up to REN=5.

Loop Closure Threshold

3

 

0-63 

Sets loop closure (off-hook) sensing threshold.  

 

 

 

 

 

Current sensing:  1.27 ma/unit (e.g. ‘8’=10.26 mA) 

 

 

 

 

 

Voltage Sensing:  1.45 V/unit (e.g. ‘10’=14.50 V) 

 

 

 

 

Recommended settings: 

 

 

 

 

 

REN<=1:  Current sensing; threshold=8  [default] 

 

 

 

 

 

For REN>1 to REN=5: Voltage sensing; threshold=10

Notes:
1.  Available on firmware versions 140725 and higher
2.  12 on firmware versions 131011 and lower
3.  Available on firmware versions 140207 and higher
4.  Available on firmware 150908 and higher.
5.  Available on firmware 160714 and higher.
  

D – DEFAULTS Command:

Entering the ‘D’ command will change all of the settings back to the factory defaults. These settings will not be 
saved unless the ‘X’ Exit and Save command is issued. Older versions of firmware will request that the POTSwap 
be restarted to effect the changes; current versions will restart automatically.

X – EXIT AND SAVE Command:

Entering the ‘X’ command will save any changes made using the ’M’ Modify or ‘D’ Defaults commands. This will 
also exit the menu system and requires that the POTSwap be restarted either by pressing the RESET push button 
or by un-powering and re-powering the unit.

Q – QUIT AND DISCARD Command:

Entering the ‘Q’ command will discard any changes made using the ’M’ Modify or ‘D’ Defaults commands. This 
will also exit the menu system and requires that the POTSwap be restarted either by pressing the RESET push 
button or by un-powering and re-powering the unit.

Содержание POTSwap HSPA910PS

Страница 1: ...POTSwap HSPA910PS v1 00 Product User Manual Bulletin JA16 GSM UM Revision P09 Date 03 Jan 2018 ...

Страница 2: ...3 2 Voice Operation 3 2 1 Placing Calls Manual Telephones Automated Dialers 3 2 2 Receiving Calls 3 2 3 Call Disconnect 3 2 4 Call Unconnected Busy 4 Configuration 7 10 5 External Interface 11 14 5 1 Front Panel Received Signal Strength Indicator LED Operational indicators POWER RED LED CELLULAR YELLOW LED STATUS GREEN LED PUSH BUTTONS PHONE FXS Connector 5 2 Rear Panel Power connectors Antenna co...

Страница 3: ...erein and does not accept any liability for any injury loss or damage of any kind incurred by use of or reliance upon the information Connor Winfield disclaims any and all responsibility for the application of the devices characterized in this document and notes that the application of the device must comply with the safety standards of the applicable country and where applicable with the relevant...

Страница 4: ...nd can be configured to emulate all international telephone line standards Wireless connectivity is provided by the Janus line of Plug In Terminus terminal modems which provide support for all current mobile network technologies with service available from numerous wireless carriers Configuration of the POTSwap can be achieved via a local serial interface connection 2 Plug In Terminus Cellular com...

Страница 5: ...t Once powered the unit should show a connection to the cellular carrier within a minute This will be indicated by a rapidly flashing GREEN STATUS LED a blinking CELLULAR LED and a steady signal strength indication on the Received Signal Strength LED stack 3 2 Voice Operation Voice operation requires a standard voice telephone device to be connected to the POTSwap 3 2 1 Placing calls When the conn...

Страница 6: ...placing the connected telephone equipment on hook If a cellular call is terminated on the carrier side the result of a connected party ending the call or due to loss of signal the POTSwap will use an Open Switching Interval to aid in disconnecting automated type telephone equipment It removes the voltage from the phone line connection for a short time to signal that the call has been terminated Th...

Страница 7: ...al interface DVI PCM to SLIC HE910 Power Up Mode Board has SiLabs Wire Line Modem E911 Voice Calling where system configuration permit allow Installer responsible for validation of service WireLine_Open 7 Speaker Level 4 Microphone Level 1 Echo Cancellation 25 Transport Mode 1 TTY Mode 900 Open Switching Interval 30000 Dialing Tone Timeout 4000 Dialing Digit Timeout 6000 Busy Dwell Timeout 0 Fixed...

Страница 8: ...n of the POTSwap DEBUG xx DO NOT USE Factory use only DUMP Adr Len DO NOT USE Factory use only XMODEM Used for firmware upgrades REBOOT Entering REBOOT will restart the POTSwap similar to pressing the RESET button CONFIG Entering CONFIG will cause the configuration menu to be output Janus Remote Communications WireLine II Board POTSwap Configuration Microphone Level 4 0 7 Speaker Level 7 0 14 Echo...

Страница 9: ...l from the carrier side a dialing timeout or a locally generated busy tone AKA Kewlstart Dialing Tone Timeout1 30000 500 60000 Sets time limit for first dialing digit to be entered following going milliseconds off hook Exceeding the time limit will cause Open Switching Interval to be generated Dialing Digit Timeout1 6000 250 15000 Sets time limit for time between entering dialing digits millisecon...

Страница 10: ...1 27 ma unit e g 8 10 26 mA Voltage Sensing 1 45 V unit e g 10 14 50 V Recommended settings REN 1 Current sensing threshold 8 default For REN 1 to REN 5 Voltage sensing threshold 10 Notes 1 Available on firmware versions 140725 and higher 2 12 on firmware versions 131011 and lower 3 Available on firmware versions 140207 and higher 4 Available on firmware 150908 and higher 5 Available on firmware 1...

Страница 11: ...from bottom to top and back in a scanning manner GPS INDICATOR The bottom 1 Marginal LED on the RSSI indicator will blink several times for 1 second every 10 seconds to indicate a GPS location fix is available This indication is independent of the cellular signal strength indication See section 7 GPS LED Operational indicators LED LED COLOR INDICATION POWER Red Power status CELLULAR Yellow ellular...

Страница 12: ...tializing PUSH BUTTONS Three push buttons are provided on the front panel of the POTSwap These can be operated with a small diameter object such as a paperclip There is tactile feedback that indicates when the push button has been operated Applying pressure to the push buttons beyond the point at which they actuate can damage the switch Currently the SELECT and MODE push buttons are not supported ...

Страница 13: ... including screw terminal spring clamp and crimp terminal type See Section 9 Compatible Terminal Block Connectors Circular Jack The circular DC jack has a 6 mm hole diameter and a 2 mm center pin It is designed to accept a 5 5 mm diameter plug with a 2 1 mm center hole and a 8 5 mm barrel length The center pin is the positive terminal Antenna Connectors CELLULAR A standard 50 ohm SMA connector is ...

Страница 14: ...IAL PORT PINS PIN NUMBER FUNCTION NEMONIC DIRECTION 1 CARRIER DETECT CD OUTPUT 2 RECEIVED DATA RX OUTPUT 3 TANSMITTED DATA TX INPUT 4 DATA TERMINAL READY DTR INPUT 5 GROUND GND 6 DATA SET READY DSR OUTPUT 7 READY TO SEND RTS INPUT 8 CLEAR TO SEND CTS OUTPUT 9 RING INDICATOR RI OUTPUT Default communications protocol is 115200 baud 8 N 1 8 data bits no parity 1 stop bit with no handshaking SERIAL CO...

Страница 15: ...allation of an activated SIM card for operation The SIM card installation can be performed as follows Requirements POTSwap containing a Plug In Terminus with SIM card socket model HSPA910PS Mini 2FF size SIM card T10 TORX screwdriver Procedure 1 Disconnect all external cables from the POTSwap Remove the four TORX T10 screws from the rear enclosure panel the end that contains the POWER and SERIAL P...

Страница 16: ...rd socket towards the outer edge of the POTSwap to unlock it as shown in the figure below The card holder is hinged on the outer edge lift it up and slide the SIM card into the holder flat end first chamfered end up The gold contacts on the SIM card will face down when the SIM card holder is closed Slide the card holder towards the center of the POTSwap to lock the card in place 4 Slide the board ...

Страница 17: ...ndoors placement as near as possible to a window is preferable Receiving a GPS location fix deep inside buildings or in dense urban environments street canyons is normally not possible 7 4 GPS Troubleshooting With a terminal attached to the SERIAL port debug messages are available that can be used to monitor the GPS operation See section 4 Configuration for information on attaching a terminal to t...

Страница 18: ...ameters Description SLIC Performs all BORSCHT functions Battery supply to subscriber line Overvoltage protection Ringing current supply Supervision of subscriber terminal Coder and decoder Hybrid 2 wire to 4 wire conversion Testing DTMF encoding and decoding REN 5 at 100 ft 30m Voice Voice over cellular Cellular Connection HSPA910PS model supports GSM GPRS EDGE and WCDMA HSPA Frequency Bands GSM G...

Страница 19: ...mple of compatible connectors TYPE MANUFACTURER PART NO DESCRIPTION Screw Terminal TE Connectivity1 796634 2 vertical screw horizontal plug TE Connectivity 1986484 2 horizontal screw vertical plug Molex 395300002 vertical screw horizontal plug Molex 395332002 horizontal screw vertical plug Weidmuller 1943580000 vertical screw horizontal plug Spring Clamp Weidmuller 1013680000 orange Weidmuller 101...

Страница 20: ...ase P01 03 03 14 Overall Product Update Changes P02 05 08 14 Updated to GSM Version Only HSPA910PS P03 08 19 14 Updated Voice Operations and Configurations P04 08 11 15 Update to Enclosure and Dimensions P05 09 05 15 Operation Configuration Interfaces P06 08 01 16 Added GPS Information P07 08 31 16 Added SIM Card Size P08 07 13 17 Added v2 00 EVDO version to Ordering Information P09 01 03 18 Updat...

Отзывы: