PRE-TESTING 

 

1.  Remove intercom system from shipping box. If you want 

to test the intercom before installation, connect a pair of 
wires from the white terminal strip to the TELCO block 
on the cab unit. Be sure that the positive side of the 
European connector is connected to the positive side of 
the TELCO block. See markings on the connector and 
on the PC board beside the TELCO block for proper 
terminal designations. 

2.   Plug the AC power supply into 110VAC outlet and 

connect the 9-volt battery to the battery snap. 

3.  

Take the elevator unit into an adjoining room and close 
the door. 

4.   The person at the machine room phone should pick up 

the handset. If it is a simplex unit (no pushbuttons), 
communication can begin. If the unit is a duplex (2 
button) or triplex (3 button), the person needs to press 
the appropriate pushbutton to communicate with the 
elevator cab unit. 

5. Check each elevator unit in the same manner. 

 

 
 
 
 
 
 
 
 
 
 
 
 

 

4

 

Содержание HDSICM ONE WAY INTERCOM

Страница 1: ...ER S MANUAL Janus Elevator Products Inc 125 Ricefield Lane Hauppauge New York 11788 Phone 631 864 3699 Toll Free 800 527 9156 Fax 631 864 2631 Email sales januselevator com AVAILABLE IN THE U S THROUGH www electronicmicrosystems com www januselevator com ...

Страница 2: ...TABLE OF CONTENTS SECTION PAGE FEATURES 3 OPERATION 3 PRE TESTING 4 INSTALLATION 5 TROUBLESHOOTING 6 WARRANTY POLICY 8 RETURN POLICY 9 2 ...

Страница 3: ...odels for multiple cabs Cab unit can mount on ceiling using provided enclosure or can be mounted behind speaker pattern if removed from enclosure OPERATION 1 Remove the handset from the telephone and it will automatically establish communication with the elevator unit If there are 2 or more buttons on the telephone press the appropriate button to establish communication with the unit you need to c...

Страница 4: ... board beside the TELCO block for proper terminal designations 2 Plug the AC power supply into 110VAC outlet and connect the 9 volt battery to the battery snap 3 Take the elevator unit into an adjoining room and close the door 4 The person at the machine room phone should pick up the handset If it is a simplex unit no pushbuttons communication can begin If the unit is a duplex 2 button or triplex ...

Страница 5: ...he intercom board from the galvanized enclosure 3 Install the machine room telephone on the wall using an RJ11W or equivalent 4 Connect the AC power to the machine room telephone 5 For Simplex installations connect one pair of wires between the European connector of the Machine Room telephone to the TELCO connector of the elevator unit This connection is polarity sensitive so be sure to connect th...

Страница 6: ...attery is charged If you have less than 8 volts you can temporarily replace it with any charged 9 volt battery for testing purposes The 9 volt battery supplied with the unit is rechargeable and will build up to full charge after a couple of hours connected to the power supply 4 Check to make sure voltage is being sent to the European connectors WITH THE HANDSET OFFHOOK and THE APPROPRIATE PUSH BUT...

Страница 7: ...wiring connected by attaching a 9 volt battery to the battery connector that is soldered directly onto the PC board and plugging a modular tone phone into the black jack on the back of the board You should be able to communicate through the handset to the PC board 7 ...

Страница 8: ...n Seller shall have no obligation under this Limited Warranty or otherwise if the product is altered or improperly repaired or serviced by anyone other than Janus factory service For warranty service contact Janus at 631 864 3699 or 800 527 9156 THERE ARE NO WARRANTIES EXPRESS OR IMPLIED OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE WHICH EXTEND BEYOND THE DESCRIPTION ON THE ...

Страница 9: ...es that the product is not functioning an RA Return Authorization number will be issued allowing the installer to return the product directly to Janus Elevator Products for repair replacement or credit Returns with no fault found will result in a bench charge plus shipping costs Returns without an RA number will result in a restocking charge of 25 or more plus shipping costs Need Technical Assista...

Отзывы: