![Janome 502X Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/janome/502x/502x_servicing-manual_3419035013.webp)
11
2-3 mm
TO CHECK:
SET THE PATTERN SELECTOR DIAL AT “ “ AND MAXIMUM ZIGZAG WIDTH.
IF THE NEEDLE MOVES SIDEWISE WHILE THE NEEDLE IS COMING OUT FROM THE FABRIC, ADJUST
IT AS FOLLOWS:
(THE NEEDLE SHOULD START SWINGING WHEN ITS TIP IS AT 2 MM (0.08”) TO 3 MM (0.12”) ABOVE
THE NEEDLE PLATE IN UPWARD MOTION).
ADJUSTMENT PROCEDURE:
1. REMOVE THE FACE COVER AND FRONT COVER (SEE PAGES 6 AND 7).
2. SELECT THE PATTERN SELECTOR DIAL AT “ “ AND SET THE ZIGZAG WIDTH AT “5”.
3. LOOSEN THE TWO HEXAGONAL SOCKET SCREWS ON THE UPPER SHAFT WORM.
4. WHILE HOLDING THE UPPER SHAFT WORM IN PLACE, CAREFULLY TURN THE HANDWHEEL AND
ADJUST SO THAT LATERAL NEEDLE SWING STARTS FROM A POSITION 2 MM (0.08”) TO 3 MM
(0.12”) ABOVE THE NEEDLE PLATE IN RIGHT OUTFLOW MOTION.
5. TIGHTEN THE TWO HEXAGONAL SOCKET SCREWS ON THE UPPER SHAFT WORM.
6. ATTACH THE FRONT COVER AND FACE COVER.
NOTE:
MAKE SURE THAT THERE IS NO BACKLASH BETWEEN THE UPPER SHAFT WORM AND
CAM BLOCK GEAR, AND THE UPPER SHAFT SHOULD TURN SMOOTHLY.
NEEDLE PLATE
GEAR
UPPER SHAFT WORM
THE BACKLASH IS
INCREASED.
THE BACKLASH IS
DECREASED.
IF THE UPPER SHAFT WORM DEVIATES LATERALLY
WHEN TURNING THE UPPER SHAFT, THE BACKLASH
BETWEEN THE GEARS WILL CHANGE.
MECHANICAL ADJUSTMENT
NEEDLE SWING
HEXAGONAL SOCKET
SCREWS
(RIGHT OUTFLOW MOTION)
www.promelectroavtomat.ru