background image

16

800-DI14 module

www.janitza.de

3.8  Scope of delivery

Quantity Part. no.

Designation

1

52.31.214. 800-DI14 module 

(digital input module)

1

52.31.206 1TE module bus connector

1

33.03.886

Installation instructions (DE/EN)  

"Digital input module for the 

UMG 801"

1

33.03.342 "Safety information” supplement 

(12 languages)

Tab. Scope of delivery for 800-DI14 digital input module

INFORMATION

 ·The modules are delivered with the necessary 

screw terminals and bus connectors (JanBus in-

terface) for connection to the basic device or other 

modules.

 ·All supplied options and design variants are de-

scribed on the delivery note.

 ·The GridVis

®

 network analysis software is available 

at www.janitza.de and can be used to configure 

your basic device with modules and read out data 

for analysis (prerequisite: PC connection to your 

basic device).

3.9  Accessories

Quantity

Part. no.

Designation

1

10.01.953 End bracket

Tab. Accessories

3.10 Operating concept

Options to configure the basic device with digital 
input module or to read measured values:

 ·Display and buttons on the basic device (user 

interface).

 ·GridVis

®

 network analysis software.

 ·RS-485 interface or Ethernet interface.

The modules can be used to realize meter and mod-
ule topologies with a flexible arrangement of the DIN 
rails. For the operation of the devices, components 
and modules integrated in your meter and module 
topology, please refer to the respective additional 
usage information.

INFORMATION

Please refer to the user manual of the UMG 801 

basic device for the operation, configuration and 

readout of expansion modules.

This user manual describes the 800-DI14 module 

and provides information on the operation of the 

module via the basic device (UMG 801).

The GridVis

®

 software has an online help with tutori-

als.

A list of parameters and Modbus addresses with 

data on your basic device with module is available 

for you as a download at www.janitza.de.

3.11 GridVis

®

 network analysis software

With the GridVis

®

 software, you have the perfect tool 

for programming, reading out and visualizing mea-
surement data (download at www.janitza.de).

Performance characteristics of the GridVis

®

 soft-

ware

 ·Configuration of the basic device and the modules 

of your meter and module topology.

 ·Graphic display of measured values.
 ·Online help and tutorials.

Connections to the PC (GridVis

®

 software)

Information on connections for communication 
between the PC and the basic device (with modules) 
can be found in the usage information of the basic 
device.

Содержание 800-DI14

Страница 1: ...Expansion module for the UMG 801 as of firmware 1 5 0 User manual and technical data Janitza electronics GmbH Vor dem Polst ck 6 D 35633 Lahnau Support tel 49 6441 9642 22 Email info janitza com www j...

Страница 2: ...2 800 DI14 module www janitza de Digital input module 800 DI14 for the UMG 801 as of firmware 1 5 0 Doc no 2 053 097 0 a Date 06 2023 The German version is the original version of the documentation...

Страница 3: ...he current state of the information available to us Nonetheless we wish to point out that updates of this document are not always possible at the same time as technical refinements are implemented in...

Страница 4: ...modules 11 2 5 Electrically qualified personnel 12 2 6 Warranty in the event of damage 12 2 7 Safety information for handling current transformers 12 3 Product description 14 3 1 800 DI14 digital inp...

Страница 5: ...module or your module series via the Ethernet interface 28 6 3 PC direct connection of the UMG 801 basic device with digital input module or your module series via the Ethernet interface 28 6 4 Module...

Страница 6: ...Service and maintenance 40 14 1 Repair 40 14 2 Service 40 14 3 Device adjustment 40 14 4 Calibration interval 40 14 5 Firmware update 40 14 6 Procedure in the event of a malfunction 40 14 7 Resetting...

Страница 7: ...7 www janitza de 800 DI14 module...

Страница 8: ...ation accompanying the product Keep the usage information associated with the product available for the entire service life and pass it on to any possible subsequent users Find out about device revisi...

Страница 9: ...plete with accessories Observe special regulations for devices with built in batteries or rechargeable batteries Do not attempt to open or repair the device the module the component on your own becaus...

Страница 10: ...tuation which if not avoided can result in material or environmental damage INFORMATION Indicates procedures in which there is no hazard of personal injury or material damage 2 3 Product safety The de...

Страница 11: ...er circuits when open Only connect screw terminals with the same number of poles and design Do not exceed the limit values specified in the user manual and on the rating plate This must also be observ...

Страница 12: ...information for handling current transformers Definition of the terms current transformers cur rent sensors In this user manual the term current transformer is used for special transformers for the p...

Страница 13: ...transformers can be hot even after the power supply has been switched off Allow the connections of the current transformers and the connecting cables to cool down before touching them CAUTION Risk of...

Страница 14: ...being switched back on 3 Check to be sure it is de energized 4 Ground and short circuit the system device 5 Cover or block off adjacent live parts Safe operation is impossible if for example the basic...

Страница 15: ...www janitza de for the laws standards and directives applied by Janitza electronics GmbH for the devices The EU UKCA conformity of the device permits the marking CE UKCA 3 6 FCC Declaration of Conform...

Страница 16: ...thernet interface The modules can be used to realize meter and mod ule topologies with a flexible arrangement of the DIN rails For the operation of the devices components and modules integrated in you...

Страница 17: ...17 www janitza de 800 DI14 module...

Страница 18: ...ns for air or road freight complete with accessories All usage information is also available as a download at www janitza de Observe the mounting instructions for your basic device e g check the bus c...

Страница 19: ...attached module so that the bus connectors devices are coupled Fig Side view of UMG 801 and 800 DI14 module Internal bus connector UMG 801 800 DI14 module 5 Then cable your module and apply voltage to...

Страница 20: ...device allows the mounting of up to 10 modules Always start and end your device and module se ries with end brackets Basic device Module 1 System Information ESC Lorem ipsum Fig System information wi...

Страница 21: ...21 www janitza de 800 DI14 module...

Страница 22: ...operation and indicate cyclic data exchange 5 Screw terminals 8 pole Digital inputs top of module 6 Bottom bolt For mounting the module on the DIN rail 7 JanBus interface rear of module Connection con...

Страница 23: ...6 9 8 7 10 Item Designation Description 1 Part number Marking for traceability 2 Symbol for Danger sign General hazard symbol Be certain to observe the warning notices applied to the device and shown...

Страница 24: ...measuring displays 800 DI14 module only on p 32 Functions for the digital inputs can be configured easily and clearly in the GridVis software see www janitza de Digital inputs on the bottom of the mod...

Страница 25: ...t 14 Digital Inputs 8 14 C2 External Auxiliary Voltage 24 V DC 8 1 2 2k21 3 2k21 2k21 2k21 Digital Input 1 2k21 2k21 Digital Input 2 Digital Input 3 4 2k21 2k21 Digital Input 4 5 2k21 2k21 Digital Inp...

Страница 26: ...o select the menu item Diagnostics and confirm with button 3 Enter The Diagnostics window appears Fig Window Diagnostics with entries In the Diagnostics window use keys 2 5 and 5 6 to select the entry...

Страница 27: ...2 5 and 5 6 to select the menu item Module position and confirm with key 3 Enter The entry Module position blinks Use the keys 2 5 and 5 6 to enter the position number of the module to be identified...

Страница 28: ...nd PC The DHCP server automatically assigns IP addresses to the basic device with module s and to the PC DHCP server PC with GridVis Patch cable Patch cable UMG 801 with 800 DI14 module PC with GridVi...

Страница 29: ...basic device Module removal at the end of the module topology of a basic device Module removal within the module topology of a basic device Module swap Module configuration swap measurement Data stor...

Страница 30: ...connection to your basic device 7 2 Module relevant menu items of the basic device with one 800 DI14 module INFORMATION The following illustration shows module relevant menu items of the basic device...

Страница 31: ...es window appears Fig Example Digital I O status modules window with 2 800 DI14 modules ESC 2 Module 800 DI14 1 Module 800 DI14 Digital I O Status Modules The window 1 800 DI14 module shows the 14 dig...

Страница 32: ...DI8 DI9 DI10 DI11 DI12 DI13 DI14 0 1 0 1 0 0 1 1 0 1 0 0 1 1 1 Module 800 DI14 ESC Display 1 Digital input module with status mes sages for 14 digital inputs ESC Modules Basic device Digital I O Statu...

Страница 33: ...Display Module 1 information 1 2 Type Serial no Position 800 DI14 48000111 3 3 Module 800 DI14 Info 1 2 ESC HW Version SW Version SW Build 62381 9 9 9 abc999 ebgxm 0 b0 3 Module 800 DI14 Info 2 2 ESC...

Страница 34: ...in mm in Bottom view Top view View from left 26 mm 1 02 in 36 mm 1 42 in 14 mm 0 55 in 6 mm 0 24 in Rear view Connector for the bus connector Front view 90 mm 3 54 in 18 mm 0 71 in 110 mm 3 54 in Soc...

Страница 35: ...g to DIN IEC 60721 3 3 Has protection class II according to IEC 60536 VDE 0106 part 1 a ground wire connection is not required Working temperature 10 C 14 F 55 C 131 F Relative humidity 5 to 95 at 25...

Страница 36: ...the functions and data of the basic device can be found in the usage information included with the basic device or available for download at www janitza de Terminal connection capacity Connectible co...

Страница 37: ...he bottom bolts of the module with a screwdriver 1 Disconnect the supply of power to the system Secure it against being switched on Check to be sure it is de energized Ground and short circuit Cover o...

Страница 38: ...vent of an error the red LED E of the module blinks during operation at an interval of 0 5 s After the definition of the error state there is a pause of 2 s and the blink interval starts again from th...

Страница 39: ...39 www janitza de 800 DI14 module...

Страница 40: ...ION This user manual describes the modules and pro vides information on the operation of the modules via the basic device In addition to this user manual refer to the usage information for your basic...

Страница 41: ...g measured values and configuration data INFORMATION The basic device stores the following measured val ues every 5 minutes at the latest S0 meter readings Min max average values Energy values work va...

Страница 42: ...42 800 DI14 module www janitza de...

Страница 43: ...43 www janitza de 800 DI14 module...

Страница 44: ...Janitza electronics GmbH Vor dem Polst ck 6 D 35633 Lahnau Support tel 49 6441 9642 22 Email info janitza com www janitza com...

Отзывы: