background image

800-CON Modules

www.janitza.com

6

1.  Information on the devices and the user manual

1.1  Disclaimer

Compliance with the usage information for the 
devices (modules/components) is a prerequisite for 
safe operation and attaining the stated performance 
characteristics and product features.

Janitza electronics GmbH assumes no liability for 
bodily injury, material damage or financial losses 
which result from disregard of the usage information.

Ensure that the usage information for the products is 
legible and accessible.

1.2  Copyright notice

© 2022 - Janitza electronics GmbH - Lahnau. All 
rights reserved.

Any reproduction, processing, distribution or other 
use of this usage information, in whole or in part, is 
prohibited.

All trademarks and the rights arising from them are 
the property of the respective owners of these rights.

1.3  Technical changes

 ·Make sure that your device (modules/components) 

matches the user manual. 

 ·This user manual is valid for the 800-CON module 

(set of 2). Separate validities and distinctions are 
marked. 

 ·First make sure you have read and understood the 

usage information accompanying the product.

 ·Keep the usage information associated with the 

product available for the entire service life and pass 
it on to any possible subsequent users.

 ·Find out about device revisions and the associated 

modifications of the usage information associated 
with your product at www.janitza.com.

1.4  About this user manual

If you have questions, suggestions or ideas for im-
provement of the user manual, please let us know via 
email at: [email protected].

INFORMATION

This user manual describes the 800-CON module (set 

of 2) for the UMG 801 basic device and provides infor-

mation about the operation of the device and modules.

Also consult the additional usage information relevant 

for this user manual, such as:

 ·the installation instructions.

 ·the data sheet.

 ·the "Safety information" supplement.

 ·the supplement on mounting the modules.

 ·the usage information on the basic device and 

the integrated modules of your meter and module 

topology.

Moreover, the 

GridVis

®

 software has an “online 

help” feature.

INFORMATION

Our usage information uses the grammatical mascu-

line form in a gender-neutral sense! This form always 

refers equally to women, men and diverse. In order 

to make the texts more readable, distinctions are not 

made. We ask for your understanding for these simpli-

fications.

Содержание 800-CON

Страница 1: ...e Transfer module set of 2 for the UMG 801 User manual and technical data Janitza electronics GmbH Vor dem Polst ck 6 35633 Lahnau Germany Support 49 6441 9642 22 info janitza com www janitza com Doc...

Страница 2: ...800 CON Modules www janitza com 2 800 CON transfer module set of 2 for the UMG 801 Doc no 2 053 087 0 a Date 02 2023 The German version is the original edition of the documentation...

Страница 3: ...e current state of the information available to us Nonetheless we wish to point out that updates of this document are not always possible at the same time as technical refinements are implemented in o...

Страница 4: ...ormation for handling current transformers current sensors 10 3 Product description 12 3 1 800 CON module set of 2 12 3 2 Incoming goods inspection 12 3 3 Intended use 13 3 4 Overview of module functi...

Страница 5: ...n function of the meter and module topology 23 7 Device views 800 CON transfer module 24 8 Technical data 25 9 Dismounting 26 10 Service and maintenance 27 10 1 Repair 27 10 2 Service 27 10 3 Device a...

Страница 6: ...ion accompanying the product Keep the usage information associated with the product available for the entire service life and pass it on to any possible subsequent users Find out about device revision...

Страница 7: ...reight complete with accessories Observe special regulations for devices with built in batteries or rechargeable batteries Do not attempt to open or repair the device the module the component on your...

Страница 8: ...tuation which if not avoided can result in material or environmental damage INFORMATION Indicates procedures in which there is no hazard of personal injury or material damage 2 3 Product safety The de...

Страница 9: ...er circuits when open Only connect screw terminals with the same number of poles and design Do not exceed the limit values specified in the user manual and on the rating plate This must also be observ...

Страница 10: ...nty for any possible re sulting damage Note in this regard Sect 3 3 Intended use on p 13 2 7 Safety information for handling current transformers current sensors Definition of the terms current transf...

Страница 11: ...sformers can be hot even after the power supply has been switched off Allow the connections of the current transformers and the connecting cables to cool down before touching them CAUTION Risk of inju...

Страница 12: ...le tools Check the modules by performing a visual inspection to ensure flawless mechanical condition the scope of delivery see Sect 3 8 Scope of delivery 800 CON transfer module set of 2 on p 14 for c...

Страница 13: ...l data on p 25 3 5 EU conformity declaration Please see the EU declaration of conformity posted at www janitza com for the laws standards and di rectives applied by Janitza electronics GmbH for the de...

Страница 14: ...The UMG 800 CON set of 2 expansion and transfer module is used for connecting remote measurement points as previously described in Sect 3 1 800 CON module set of 2 on p 12 The modules can be used to r...

Страница 15: ...www janitza com 15 800 CON Modules...

Страница 16: ...to Janitza electronics GmbH in accordance with the shipping in structions for air or road freight complete with accessories All usage information is also available as a download at www janitza com 4 1...

Страница 17: ...a on p 25 until the 2 bottom bolts engage 800 CT8 A module Fig Side view UMG 801 800 CT8 A and 800 CON module DIN rail 800 CT8 A module Fig Side view UMG 801 800 CT8 A and 800 CON module UMG 801 4 Pus...

Страница 18: ...onnectors and the connections of your modules to the basic device JanBus interface If necessary push the contacts of the module bus connectors into the sockets of the basic device bus connector or the...

Страница 19: ...odule input bus connector Connector for insertion into the rear of the module 7 Transfer module input bus connector Sockets for module insertion INFORMATION The transfer modules 800 CON of the set of...

Страница 20: ...for Danger sign General hazard symbol Be certain to observe the warning notices applied to the device and shown in the documentation in order to avoid possible injury or even death 3 Device type Devic...

Страница 21: ...www janitza com 21 800 CON Modules...

Страница 22: ...nector from left to right This will avoid an incorrect connection of remote JanBus systems Use end brackets and shield clamps with strain relief to set up your meter and module topology on a suitable...

Страница 23: ...e 800 CON transfer modules Recommendation Use the following data cables for smooth com munication in your meter and module topology for connecting the 800 CON transfer modules 1 1 Cable connection INF...

Страница 24: ...iew from left Plug for insertion into the basic device or an attached module Bus connector for the output transfer module Sockets for module insertion Bus connector for the input transfer module Conne...

Страница 25: ...1 5 mm2 AWG 24 16 Wire ferrules non insulated 0 2 1 5 mm2 AWG 26 16 Wire ferrules insulated 0 2 1 mm2 AWG 26 18 Tightening torque 0 2 0 25 Nm 1 77 2 21 lbf in Strip length 7 mm 0 2756 in General Net...

Страница 26: ...ver 1 Disconnect the supply of power to the system Secure it against being switched on Check to be sure it is de energized Ground and short circuit Cover or block off adjacent live parts 2 Disconnect...

Страница 27: ...transfer module set of 2 For a firmware update of the further components and modules of your meter and module topology please refer to the respective usage information INFORMATION This user manual des...

Страница 28: ...Janitza electronics GmbH Vor dem Polst ck 6 35633 Lahnau Germany Support tel 49 6441 9642 22 Email info janitza com www janitza com...

Отзывы: