Section 6. Troubleshooting and Repair
Zodiac strongly recommends that you call a qualified service technician to perform any repairs on the filter/pump
system. To locate a qualified technician, check your local yellow pages or visit
www.zodiac.com
and click on “Product
Support.”
6.1 Troubleshooting
Symptom
Possible Cause/Solution
The cleaning/circulating system is
not operating correctly.
Verify that skimmer baskets, pump basket and other screens are clean. Clean as
necessary.
Check filter and clean as necessary.
Check valve positions. Adjust as necessary.
NOTE Multiple pieces of equipment operating at one time (for example, waterfalls, spa
jets, and surface returns) will affect the proper operation of the cleaning system.
Check the cleaning system manual to ensure that the system is adjusted according to the
manufacturer's recommendations.
Bubbles are present in the pump
basket.
Air is in the system. Check the pool or spa water level to ensure that it is at the proper level
and air is not being drawn into the suction piping. If the water is at the normal level, turn off
the pump. Turn the lid's locking ring counter-clockwise until 'START' aligns with the ports.
Remove the lid and check for debris around the lid seal seat OR improper installation of
the lid seal, as either condition will allow air to leak into the system. Clean the lid seal and
replace it on the lid. Replace the lid on the pump housing. Align 'START' with the ports and
turn the locking ring clockwise until 'LOCKED' aligns with the ports.
Hand-tighten
the lid to
make an air-tight seal.
Do not use any tools to tighten the lid.
Turn the pump back on.
Air leaks are still present.
Check the suction side piping union. While the pump is running, try to tighten the union. If
this does not stop the air leak, turn off the pump. Loosen both unions and slide the pump
out of the way. Remove, clean, and re-install both union o-rings.
Reposition the pump next to the piping and secure the union nuts to the pump. With clean
union o-rings, hand-tightening of the unions should create a seal. If the unions still do not
seal, gently tighten with a large pair of tongue-and-groove pliers.
Do not over-tighten
.
There is no air in the system, but
the pressure is still low.
It is possible that debris is caught in the pump impeller. The pump impeller moves the
water, and the vanes in the impeller can become blocked with debris. See
Section
6.2, Service Technician Maintenance, 6.2.1, Blocked Impeller,
in this manual for more
information.
There is no debris blocking the
impeller
and
the pressure is still
low.
The pump impeller and diffuser are showing signs of normal wear. Have a qualified service
technician check the impeller and diffuser and replace as necessary.
If the pump is part of a relatively new installation, it could be an electrical problem. Contact
a qualified service technician. Have the technician check for loose electrical connections
and check the voltage at the pump motor while it is in operation. The voltage must be within
10% of the motor's data plate rating. If the voltage is not within 10%, contact a qualified
electrician and/or the local power service provider.
Pump seal is leaking air. Have a qualified service technician replace the seal.
The pump is leaking water between
the motor and pump body.
This is caused by a damaged or failed mechanical seal. Replace the seal. See
Section 6.2,
Service Technician Maintenance, 6.2.3, Mechanical Seal Replacement,
in this manual.
The pump gets hot and shuts off
periodically.
Make sure that there is adequate room around the motor to circulate air and keep the
motor cool. Have a qualified electrician check for loose connections and check the voltage
at the pump motor while it is in operation. The voltage must be within 10% of the motor's
data plate rating. If the voltage is not within 10%, contact a qualified electrician and/or the
local power service provider.
Page 16
Jandy
®
FloPro™ Variable-Speed Pump Series VS-FHP
|
Installation and Operation Manual
ENGLISH
Содержание VS FloPro Series
Страница 2: ......
Страница 26: ...NOTES Page 26 Jandy FloPro Variable Speed Pump Series VS FHP Installation and Operation Manual ENGLISH...
Страница 27: ...NOTES Page 27 Jandy FloPro Variable Speed Pump Series VS FHP Installation and Operation Manual ENGLISH...
Страница 30: ......