background image

Page 17

  WARNING

ATTENTION INSTALLER:  If The Flow/Temp/Salinity Sensor is not installed properly, it may allow 

the Cell to operate without water flow.  This would cause a buildup of flammable gases resulting in a 

HAZARDOUS Condition.
•  Mount as shown in Figure 12 Detail A.  This will result in the most reliable operation.
•  The Flow/Temp/Salinity Sensor must be mounted:
 

(1) in the same line as the Electrolytic Cell.

 

(2) with no valves or diverters between the Flow/Temp/Salinity Sensor and Cell.

 

(3) preferably between the Pool Pump and the Cell.

•  Do not mount the Flow/Temp/Salinity Sensor as shown in Detail C of Figure 12.  This mounting 

position can be HAZARDOUS.

•  Anytime the Flow/Temp/Salinity Sensor is connected or disconnected and reconnected, the AC 

power to the unit must be turned off and back on (Cycle Power).  If power is not cycled, unreliable 

operation of the Flow/Temp/Salinity Sensor will result.

3.5  Installing the PureLink Cell and Flow/Temp/Salinity Sensor

NOTE:

  Maximum operating Pressure is 517 kPa or 75 PSI - Minimum Flow Rate is 20 GPM (76 LPM).

1.  Be sure pool pump is turned off.

2.   It is recommended that the Flow/Temp/Salinity Sensor and Electrolytic Cell be installed in the pool 

return line after the filter and heater.  Water passes through the Flow/Temp/Salinity Sensor before the 

Cell. The Cell can be installed in either a horizontal (as shown in Figure 13) or a vertical position.

3.  Position the Flow/Temp/Salinity Sensor Tee and Cell in the recommended position (see Figure 12 

Detail A, Figures 3 and 4, Figures 5 and 6, and Figure 1).

4.  Locate a suitable section of pipe, approximately 21 inches (533 mm) long or follow the recommended 

plumbing diagrams beginning on page 9, Figures 3, 4, 5, and 6.  The Flow/Temp/Salinity Sensor cable 

and Cell DC cord 

must

 be able to reach from the power center to this section.

5.  Cut out a 13

1

/

8

” (337 mm) section of the 2” (50 mm) pipe to insert the Cell. Cut an additional 2¼” to 

insert the Flow/Temp/Salinity Sensor Assembly (see Figure 14).

6.   Clean the cut ends of the pipe and 2 inch x 2 inch x 1½ inch Tee with an appropriate NSF

®

 approved 

All Purpose cleaner/primer.  Glue the PVC Tee onto the cut pipe ends using an appropriate All Purpose 

NSF

®

 approved Cement.  Tighten the PVC Union nuts. 

Hand Tighten Only. 

 Allow sufficient drying 

time before pressurizing system.

7.    Wrap the Flow/Temp/Salinity Sensor

 threads with Teflon tape ONLY (do not use silicone or pipe dope).  

Be sure the Flow/Temp/Salinity Sensor (circular metal disks) are free of glue, excess Teflon tape, or 

any other debris.

8.    Install the Flow/Temp/Salinity Sensor into the 1½ inch threaded opening of the 2 inch x 2 inch x 1½ 

inch Tee. Tighten to prevent water leakage.  

Do not over tighten.

9.    Install the strain relief provided with the PureLink Cell Kit into the low voltage knock out. Feed the 

connector end of the Flow/Temp/Salinity Sensor

 cable through the DC cord strain relief fitting.  

Be 

certain the connector is clean and dry

, then plug the cable into the connector on the power center 

Printed Circuit Board as shown in Figures 2a and 2b.  (

Do not pull Flow/Temp/Salinity Sensor cable 

too tight, allow a little slack

).

Содержание PureLink

Страница 1: ...duct must be installed and serviced by a professional pool spa service technician The procedures in this manual must be followed exactly Failure to follow warning notices and instructions may result i...

Страница 2: ......

Страница 3: ...Water Conditions 19 4 6 Chlorine Testing 19 4 7 Salt NaCl sodium chloride 19 4 7 1 What Type of Salt to Use 19 4 7 2 How Much Salt to Use 20 4 7 3 How to Add Salt to the Pool 20 Section 5 Operating I...

Страница 4: ...TECHNIQUE All electrical work must be performed by a licensed electrician and conform to all national state and local codes When installing and using this electrical equipment basic safety precautions...

Страница 5: ...not use drugs or alcohol before or during the use of a spa or hot tub to avoid unconsciousness and possible drowning Pregnant or possibly pregnant women should consult a physician before using a spa...

Страница 6: ...12 AWG 3 3mm In addition a second wire connector should be bonded with a no 8 AWG 4 115mm copper wire to any metal ladders water pipes or other metal within five 5 feet 1 52m of the tub SAVE THESE IN...

Страница 7: ...from ORP Unit to ORP Interface Aux Board The PureLink Power Center and Cell Kit uses a process known as electrolysis to produce sodium hypochlorite liquid chlorine from a low concentration of salt ad...

Страница 8: ...al Display LCD whenever the salinity button is pressed This eliminates the need for manual pool water salinity testing Pool Temperature is now available on all models by pressing the Temperature butto...

Страница 9: ...RY 24 VAC SECONDARY VAC Primary Secondary A B PureLink Back PCB Ribbon Cable from Front PCB To PureLink Cell T est Switches 4 3 2 1 RED BLK YEL GRN AquaLinkRS ORP 24VAC Flow Salinity Sensor Ribbon Cab...

Страница 10: ...C SECONDARY VAC Primary Secondary A B PureLink Back PCB Ribbon Cable from Front PCB To PureLink Cell T est Switches 4 3 2 1 RED BLK YEL GRN AquaLinkRS ORP 24VAC Flow Salinity Sensor Ribbon Cable to Ba...

Страница 11: ...n the return line to the pool after downstream all the pool equipment such as the filter or heater The Cell and Sensor Tee fitting are designed to be plumbed into 2 PVC pipe Adapters can be used for s...

Страница 12: ...quaLink RS is in Spa Mode and adjusts to 10 of the AquaLink RS output setting to ensure the spa is not over chlorinated Note The PureLink is powered from the LOAD SIDE of the pool circulation pump rel...

Страница 13: ...View Detail A Detail B Detail C Preferred Not Preferred Hazardous Spa Bypassfor Spillover Pool Return Cell Sensors Heater Spa Return JANDY JANDY AquaLink RS PureLink Power Center Figure 6 Alternate P...

Страница 14: ...the cell to operate without water flow through the cell which can create a HAZARDOUS condition Spa Return Sensors AquaPure Heater Pool Return Cell Mounted Vertically Figure 7 Hazardous Plumbing Confi...

Страница 15: ...or more away from pool spa and five 5 feet off the ground All national state and local codes are applicable note For Canadian installations the Power Center must be at least three 3 meters 9 8 feet aw...

Страница 16: ...s 7 Level the Power Center and tighten all screws ensuring that the Power Center is securely fastened to the mounting surface 8 Check source voltage All units are factory wired for 230 VAC In order to...

Страница 17: ...ecommended position see Figure 12 Detail A Figures 3 and 4 Figures 5 and 6 and Figure 1 4 Locate a suitable section of pipe approximately 21 inches 533 mm long or follow the recommended plumbing diagr...

Страница 18: ...full unions is 155 8 2 x 2 x 1 PVC Tee For a 2 pipe the cutout is 2 for the Tee For a 50 mm pipe the cutout is 77 mm for the Tee NOTE Total length of the PVC Tee is 4 Figure 12 Flow Temp Salinity Sens...

Страница 19: ...lugged in Also check the AC wiring 14 Plug the ribbon cable attached to the front cover PC board into Printed Circuit Board mounted on the backplate see Figure 2 Now reattach the power center front co...

Страница 20: ...3 by 0 85 m3 capacity 4 2 Determining Pool Size Gallons of Water in Your Pool Rectangular Pools Average length feet x average width feet x average depth feet x 7 5 gallon capacity Circular Pools Diame...

Страница 21: ...re formed This ties up the Free Chlorine in your pool and does not allow the chlorine in your pool to disinfect Chloramines also cloud pool water and burn the eyes Super Chlorinate shock to remove Chl...

Страница 22: ...to remove all Chloramines pH 7 2 7 8 USE MURIATIC ACID to lower pH and Soda Ash to raise pH Chlorine Stabilizer Cyanuric Acid 50 75 PPM Total Alkalinity 80 120 PPM Calcium Hardness 150 400 PPM Metals...

Страница 23: ...pl may damage the power center High salt concentration above 6 0 gpl may cause corrosion damage to pool fixtures NOTE Should too much salt be inadvertently added to the pool see Section 7 Troubleshoot...

Страница 24: ...00 lbs 102 kg 225 lbs 113 kg 250 lbs 125 kg 275 lbs 136 kg 300 lbs 147 kg 325 lbs 159 kg 350 lbs 170 kg 375 lbs 1 75 g L 48 kg 105 lbs 59 kg 130 lbs 68 kg 150 lbs 77 kg 170 lbs 86 kg 190 lbs 95 kg 210...

Страница 25: ...kg 7 50 lbs 3 7 kg 8 25 lbs 4 kg 9 00 lbs 4 4 kg 9 75 lbs 4 8 kg 10 5 lbs 5 3 kg 11 75 lbs 40 PPM 1 3 kg 2 90 lbs 1 6 kg 3 50 lbs 1 8 kg 4 00 lbs 2 kg 4 60 lbs 2 4 kg 5 25 lbs 2 6 kg 5 80 lbs 2 9 kg...

Страница 26: ...sh intermittently Boost can be used to set chlorine production to maximum 100 for 24 hours of operation After 24 hours of chlorinator run time chlorine production will return to previous setting To cl...

Страница 27: ...long with the gpl grams per liter indicator when the Salinity button is depressed If a reading of HH appears the salinity is above 4 5 to 6 5 gpl depending on pool temperature and is too high to measu...

Страница 28: ...eper volume setting The change will be stored in permanent memory If you do not wish to keep the change wait 5 seconds and the change screen will time out and return to normal operation without keepin...

Страница 29: ...o pages 18 through 20 and adjust salt level Maintain the Recommended Salinity Level of 3 0 to 3 5 gpl If salinity is below 2 0 gpl the AquaPure will automatically turn the cell off until the salinity...

Страница 30: ...Fall and Winter seasons Take pool water sample to Pool Professional once per month DON T List Do not get fertilizer in your pool Fertilizers contain nitrates which cause a high chlorine demand on pool...

Страница 31: ...3 0 3 5 gpl for optimum performance of the AquaPure If additional salt is required follow the procedures and charts described in Section 4 If salt level does not rise after 24 hours see Section 7 Trou...

Страница 32: ...EANING PROCESS go on to next step d Otherwise allow the cell to remain in the solution until the foaming has stopped However do not leave in acid for more than 1 2 hour Excessive Acid Washing will dam...

Страница 33: ...p continuously or winterize pool by draining water from pump filter and all intake and return lines Remove the cell clean and store it Disconnect the Flow Temp Salinity Sensor from the power center th...

Страница 34: ...oost mode and allow to run for 24 hours Recheck If still too low Super Chlorinate with outside source Take pool water sample to Pool Professional See Section 5 Operating Instructions Low Less than 2 5...

Страница 35: ...in the AquaPure cell Remove cell for inspection Follow cleaning procedures See Section 6 4 Electrolytic Cell Cleaning Flow Temp Salinity Sensor not installed properly Ensure that the Flow Temp Salini...

Страница 36: ...uit board Cycle Power Water temperature too low Winterize your pool See Section 6 6 Winterizing All the above have been checked and indicator light is still on Contact your authorized service represen...

Страница 37: ...tive 171 Possible Backboard service condition Contact an authorized service representative 172 Flow Sensor service condition or flow sensor is unplugged Contact an authorized service representative 17...

Страница 38: ...ressing C The change will be stored in permanent memory NOTE The Boost mode will normally be activated if the Boost button D is depressed for 10 seconds However if button D is held down an additional...

Страница 39: ...ower Center Battery Cover PureLink Power Center Screws Bezel Cover Plate Screws Bezel Support Plate Screw Battery Cover 1 1 1 2 2 1 3 R0447300 Battery Door PureLink Power Center Screw Battery Cover 1...

Страница 40: ...PVC 1 5 R0412600 Union Half Unthreaded 2 PVC 1 6 R0412700 Union O ring 2 1 7 R0412800 Spool Piece 2 PVC Unions Optional 1 Figure 21 Flow Sensor and Cable 9 3 PureLink Flow Sensor Replacement Parts Dwg...

Страница 41: ...Page 41 Notes...

Страница 42: ...Page 42 Notes...

Страница 43: ...Page 43...

Страница 44: ...imum and maximum specifications 7 Use of non factory authorized parts or accessories in conjunction with the product s 8 Chemical contamination of combustion air or improper use of sanitizing chemical...

Отзывы: