background image

Page 7

JS Series Sidemount Sand Filters

3. 

A visual inspection of all parts should be made 
now. See parts list in Section 9.

4. 

With the carton in an upright position, remove the 
filter tank from the carton.  

5. 

To mount the pressure gauge/air release assembly, 
located in the accessory bag, to the lid of the filter 
tank: 

a. 

Place the smaller, thicker o-ring onto the 

threads of the tank adapter. See Figure 4. 

Slide the tank adapter through the coupling 

nut and into the filter tank lid. Use the 

flats on the tank adapter to tighten. Do not 

overtighten.

b. 

Place the larger, thinner o-ring onto the 

gauge housing. Thread the housing into the 

coupler on the tank adapter.

c. 

Orient the gauge/air release assembly in the 

desired position. Raise and thread the locknut 

onto the bottom of the gauge/air release 

assembly. Hand tighten the nut only. Using 

a wrench to tighten the nut may damage the 

nut, gauge or air release assembly. 

3.4 Filter Plumbing

 WARNING

To avoid an electrical shock hazard, which can result 
in serious injury or death, ensure that all electrical 
power to the system is turned off before approaching, 
inspecting or troubleshooting any leaking valves 
or plumbing that may have caused other electrical 
devices in the surrounding area to get wet.

1. 

This filter operates under pressure. When lid is 

installed properly and operated without air in 

the water system, this filter will operate in a safe 

manner.

2. 

If the system can be subjected to higher pressure 

than the maximum rating of any component, 

install an ASME

®

 approved automatic pressure 

relief valve or pressure regulator in the circulation 

system. Set the relief valve or pressure regulator to 

lowest working pressure of any of the components 

in the system.

3. 

A positive shutoff valve at the outlet piping of 

the filter is not recommended. If the pump is 

operated with a shutoff at the filter outlet closed, 

an explosive condition could result from back 

pressure and the possibility of entrapped air in 

the filter. Sometimes equipment isolation shutoff 

valves are required in installation with the filter 

and other equipment below the pool water level to 

allow for equipment maintenance without draining 

down the pool. In this event, any shutoff valves 

are to be prominently labeled “Warning: Explosive 

Hazard. Do Not Run System With Valve Closed”.

Running pumps with no flow will also seriously 

damage the equipment.

4. 

Never install a chemical feeder or chlorine 

generator upstream of the filter or heater. Install 

downstream of the filter and heater and install a 

check valve to prevent water from back flowing 

from the chlorinator or feeder.

 CAUTION

Creating high vacuum levels can cause the tank 
vessel to crack and leak with the potential for property 
damage.

5. 

This is a pressure filter.  Install only on the 

discharge side of a pump system.

6. 

Backwash (waste) piping that discharges water 

at an elevation of 10 ft. or lower than the water 

surface of the pool should be equipped with a 

vacuum-breaker in the waste piping within 10 

ft. in vertical drop from the elevation of the pool 

surface.

7. 

Place the filter on the concrete pad, lined up with 

the inlet/outlet pipes. See Figure 5. 

8. 

To reduce pressure losses, 2" (minimum) piping is 

recommended for plumbing the system.

9. 

For best efficiency use the fewest possible number 

of fittings. This will prevent a restriction in the 

water flow.

a. 

The larger JS series sand filters come with 

a Jandy Sweep Elbow for this purpose.  

The sweep elbow also includes a threaded 

port and plug so that a ½" hose bib can be 

connected for pressure testing. See Figure 6.

b. 

To install the sweep elbow follow the 

instructions in Steps 9.c and 9.d.

Figure 4.  Pressure Gauge/Air Release Assembly

Housing

O-Ring

O-Ring

Tank Adapter

Union Nut

Lid

Содержание JS Series

Страница 1: ...sufficient experience in pool equipment installation and maintenance so that all of the instructions in this manual can be followed exactly Before installing this product read and follow all warning notices and instructions that accompany this product Failure to follow warning notices and instructions may result in property damage personal injury or death Improper installation and or operation can...

Страница 2: ......

Страница 3: ...er Plumbing 7 3 5 Filling Filter with Sand 9 3 6 Use of Zeobrite as an Alternative to Sand 10 3 7 Lid Installation 10 Section 4 Start Up and Operation 11 Section 5 Filter Cleaning 12 5 1 Filter Cleaning Instructions 12 5 2 Optimal Filter Performance 13 5 3 Chemical Cleaning Procedure 13 Section 6 Maintenance 14 6 1 General Maintenance 14 6 2 Pressure Gauge 14 Section 7 Winterizing 14 Section 8 Rem...

Страница 4: ...rviced air can enter the system and become pressurized when the system is restarted Pressurized air can cause product failure or also cause the filter lid to be blown off which can result in death serious personal injury or property damage To avoid this potential hazard follow all of the instructions in this manual WARNING To minimize risk of severe injury or death the filter and or pump should no...

Страница 5: ...e of water in your pool two 2 to four 4 times in a 24 hour period 2 3 General Requirements 1 For best overall performance place the system as close to the pool as possible 2 The filter should be located on a level concrete slab so that the orientation of the valve outlets and the pressure gauge are convenient and accessible for the installation and operation of the unit 3 Protect the filter from t...

Страница 6: ... isolation valves should be installed on both the suction and return lines to prevent back flow of pool water during any routine servicing that may be required 3 2 Anchoring the Filter to the Equipment Pad In some areas for example Florida building codes require that all appliances be securely fastened to the equipment pad in order to withstand high wind pressures created by hurricanes Please foll...

Страница 7: ...iping of the filter is not recommended If the pump is operated with a shutoff at the filter outlet closed an explosive condition could result from back pressure and the possibility of entrapped air in the filter Sometimes equipment isolation shutoff valves are required in installation with the filter and other equipment below the pool water level to allow for equipment maintenance without draining...

Страница 8: ...cone base lubricant on the o rings Do not use pipe joint compound glue or solvent on inlet outlet union coupling nuts 11 Keep piping tight and free of leaks Pump suction line leaks may cause air to be entrapped in filter tank or loss of prime at the pump Pump discharge line leaks may show up as dampness or jets of water 12 Support the inlet outlet pipes independently to prevent any undue strains o...

Страница 9: ...e the laterals spokes are screwed firmly into the hub and that the hub is centered in the tank with the laterals spokes horizontal CAUTION To avoid damaging the laterals spokes slowly add the filter media until the laterals are fully covered Cracked or broken laterals spokes will cause sand to be discharged to the pool 3 Add water to approximately 4 above the level of the laterals 4a For the JS60 ...

Страница 10: ...ater it is recommended that a pea gravel bed be used before adding the filter media See Table 3 for the type and amount of pea gravel to use Ensure the top surface of the pea gravel is flat before adding filter media Using the correct pea gravel will ensure that the filter media is evenly lifted during backwashing cycles and settles evenly after backwashing to optimize filter performance The pea g...

Страница 11: ...debris and dirt particles NOTE If the pool is a new concrete or gunite pool or has a lot of debris or plaster dust that was not removed before the pool was filled and difficult to removed start the filter with the backwash valve selector set on FILTER mode and run for 48 hours After step 3 go directly to steps 12 though 16 After the initial 48 hours in FILTER mode stop the pump and backwash the fi...

Страница 12: ...he filter cleans the water and the sand begins to clog the pressure will increase When the needle of the pressure gauge aligns with the arrow next to the word DIRTY on the bezel it is time to clean the filter see Cleaning Instructions This indicates an increased pressure of between 10 and 12 psi above original starting pressure NOTE Record this initial CLEAN pressure This reference will be necessa...

Страница 13: ...minish the filter performance by limiting its ability to catch finer particles For the best filtration do not run your system continually for 24 hours day after day Allowing the filter to stop periodically will allow slight disturbance of the mud deck at the surface of the sand bed which will lower the running pressure slightly after rest and lengthen the time between backwashing without any decre...

Страница 14: ...e assembly for air or water leaks at least once a week 2 Keep the pressure gauge in good working order If you suspect a problem with the gauge Zodiac recommends you call a qualified service technician to do any work on the filter pump system Section 7 Winterizing 1 Backwash the filter See Section 5 Filter Cleaning 2 Turn OFF the pump and circuit breakers 3 Open the air release valve on top of the ...

Страница 15: ... of common problems and solutions see the Troubleshooting Guide 2 Zodiac recommends that you call a qualified service technician to do any work on the filter pump system To locate a service company near you please visit www jandy com For technical support please call 800 822 7933 ...

Страница 16: ...effective cleaning Check disinfectant content Check pH total alkalinity and TDS Check pump performance Clean or replace sand or filter media per instructions High pressure on start up Small eyeball fitting in Pool Spa Partially closed valve on return line Too large of pump Sand bed clogged Incorrect size of sand Replace with larger diameter fitting Check and fully open all valves on return line Ch...

Страница 17: ... Elbow SEFL 1002 Not Shown Section 10 Parts List and Exploded View 10 1 Jandy JS60 SM Sand Filter Parts List Trademarks used herein are the property of their respective owners Key No Description Part No 1 Lid Sand Filter R0487300 2 Lid Seal Sand Filter R0487400 3 Gauge Air Release Assembly R0357200 4 Pressure Gauge R0359600 5 Tank Adapter with O Ring and Union R0552000 6 Diffuser R0487500 7 Air Re...

Страница 18: ...8 JS Series Sidemount Sand Filters 10 3 Jandy JS60 SM Sand Filter Exploded View 3 5 3 1 10 17 9 10 18 8 15 16 15 16 15 16 13 14 13 15 16 17 18 6 2 16 Detail 7 12 16 INLET INLET OUTLET OUTLET 4 11 16 16 16 16 ...

Страница 19: ...S Series Sidemount Sand Filters 3 3 5 1 2 16 Detail 7 6 8 17 18 13 15 16 15 16 15 16 15 16 14 13 11 10 17 10 18 8 9 8 6 12 16 INLET OUTLET INLET OUTLET 4 16 16 16 16 10 4 Jandy JS100 SM Sand Filter Exploded View ...

Страница 20: ...es Sidemount Sand Filters H0282300 RevG Section 11 Head Loss Curves 11 1 Jandy JS Series Sand Filters Design Head Loss Curves Head Loss JS Series Sand Filters 20 Silica Sand 0 2 4 6 8 10 12 14 16 0 10 20 30 40 50 60 70 80 90 100 110 120 Flow Rate gpm Design Head Loss ft head 0 0 1 0 2 0 3 0 4 0 5 0 6 0 Design Pressure Drop psi JS60 SM JS100 SM ...

Отзывы: